SURT2000XLICH

NegotiableUpdate on 08/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

APCSmart-UPSOn-Line

Product Details

APC Smart-UPS On-Line,1400 Watts /2000 VA, Input 230V/output 230V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model, device installation effective height 2 U

Smart UPS On Line Performance and Advantages

usability
Automatic internal bypass
Provide common power to the connected load in the event of overload or malfunction of the UPS power supply.
Scalable runtime
Allow for quick increase of more running time when needed
Intelligent battery management
Obtain optimal battery performance, lifespan, and reliability through intelligent and precise charging technology.
Hot swappable battery
Ensure a clean and uninterrupted power supply throughout the battery replacement process to protect the equipment
Automatically restart the load after UPS shutdown
Once the mains power is restored, the connected devices will automatically restart.
Temperature compensation battery charging
Adjust the charging voltage according to the actual battery temperature to extend the battery life
Manageability
network management
Realize remote power management for UPS through the network.
Compatible with Yingfei Manager
In order to achieve centralized management through APC's Yingfei Manager software.
SmartSlot Slot Slot
Customize UPS performance using management cards
LED status indicator light
With the help of video indicators, device and power status can be quickly understood.
serial connection
Manage UPS through serial port.
adaptability
Plug and play external battery
Ensure clean and uninterrupted power supply to the load when adding additional operating time to UPS
Frame/Tower Conversion
Protecting the initial investment in UPS when migrating from tower to cabinet installation environment
Flash upgradable firmware
Use FTP to remotely install the maintenance version of firmware.
Serviceability
User replaceable battery
Can easily upgrade and replace batteries
Automatic self check
Regularly self check the battery to ensure early detection of batteries that need to be replaced.
Predictable fault notifications
The early warning fault analysis provided ensures timely replacement of components
Notice of battery disconnection
Warning when the battery cannot provide backup power
Audible Alarm
Provide notification of changes to the conditions of the mains and UPS power supply
system protection
Frequency and voltage adjustment
Poor frequency and voltage conditions can be corrected without using batteries, providing higher availability.
Power regulation
Protect the connected load from the effects of surges, spikes, lightning, and other power disturbances.
Input power factor correction
By using a small generator and connecting wires, the installation cost is minimized
Compatible with generators
When using the generator power supply, ensure a clean and uninterrupted power supply to protect the equipment
Cold start capability
Provide temporary battery power supply when the mains power stops
Resettable circuit switch
It is easy to recover from overload without replacing the fuse.
Certified by security agencies
The product has been tested and certified to ensure safe operation with the connected service provider equipment within the specified environment.

usability

China

output

Output power capacity
1400 watts/2000 VA
Maximum configurable power
1400 watts/2000 VA
rated output voltage
230V
Adjustable range of output voltage
Can be set to output voltage of 220, 230, or 240
full-load efficiency
90%
Output voltage distortion
Less than 3%
Output frequency (synchronized with the main frequency)
50/60 Hz+/-3 Hz User adjustable+/-0.1
Other output voltages
220, 240
crest factor
03:01
topology
Dual conversion online
Waveform type
sine wave
Output Connection
(6) IEC 320 C13
(2) IEC Jumpers
bypass
Built in bypass

input

Rated input voltage
230V
input frequency
50/60 Hz+/-5 Hz (automatic adaptation)
Input terminal type
IEC-320 C20
Working voltage range
160 - 280V
Adjustable input voltage range
100 - 280V
Other input voltages
220, 240

Battery and running time

model No
Maintenance free sealed lead-acid battery (suspended electrolyte): leak proof
Typical charging time
4 hours
Replaceable battery pack
RBC31
RBC ™ quantity
1
Optional battery
APC Smart-UPS RT 2000VA 230V For China
Run time chart
Curve Part Number(s)
A SURT2000XLICH
B SURT2000XLICH
+ (1)SURT48XLBP
C SURT2000XLICH
+ (5)SURT48XLBP
D SURT2000XLICH
+ (10)SURT48XLBP
Browse the runtime chart above to viewDetails of runtime and load ratio
The running time data obtained by curve fitting. All measurements were conducted using fully charged new batteries, under typical environmental conditions, and without power input or resistive load output.

Communication and Management

interface port
DB-9 RS-232, SmartSlot slot
Number of available smart slots
1
control panel
The LED status display includes load and battery bar charts, as well as "online", "battery on", "battery replacement", "overload", and "bypass" indicators.
Audible Alarm
Alarm during power outage: Special low battery alarm overload continuous tone alarm
emergency shutdown
optional

Surge protection and filtering

Surge suppression energy
420 joules
filter
Multi level noise filter, compliant with UL1449 standard

Physical indicators

tall
432.00 mm
wide
85.00 mm
deep
483.00 mm
Effective height for equipment installation
2U
net weight
25.00 KG
Transport weight
29.82 KG
Transportation height
286.00 mm
Transportation width
630.00 mm
Transportation length
594.00 mm
colour
black
Quantity of products on each transport pallet
12.00

environment

work environment
0 - 40 °C
Relative humidity at work
0 - 95% no%
Operating height
0-3000 meters
storage temperature
-20 - 50 °C
Store relative humidity
0 - 95% no%
Storage height
0-15000 meters
Auditory noise at a distance of 1 meter from the surface of the device
50.00 dBA
Online operation dissipates heat
543.00 BTU/hr
Protection level
IP 20

Compliance

Management organization certification
C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDE
Standard Warranty
Repair or replacement within 2 years, on-site service, optional extended warranty period available

Sustainable provision status

PEP
Available in Documentation tab
EOLI
Available in Documentation tab
**The time required for UPS to discharge with 50% rated capacity load until shutdown, and then recharge to 90% battery capacity.


施耐德SPupsapc.jpgSchneider APC uninterruptible power supply, precision air conditioning, cabinet, PDU, KVM and other integrated computer room power distribution!

APC电源