Schneider Symmetra MW 1600kW Framework, 400V SYMF1600KH

NegotiableUpdate on 08/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Characteristics and advantages of SymmetraMW: Overall cost of ownership, full rated power supply kW equals kVA. By eliminating the need for power factor correction (PFC) load in large-scale UPS, the cost of input power factor correction is reduced. By using a small generator and wire connection, the installation cost is minimized. Temperature compensation battery charging adjusts the charging voltage according to the actual battery temperature to extend the battery life. Automatic self inspection and regular self inspection of the battery ensure early detection of batteries that need to be replaced

Product Details

Characteristics and advantages of Symmetra MW

Total Cost of Ownership
  • Full rated power supply kW equals kVA
    Reduce costs by eliminating the demand for power factor correction (PFC) loads in ultra large scale UPS systems
  • Input power factor correction
    By using a small generator and connecting wires, the installation cost is minimized
  • Temperature compensation battery charging
    Adjust the charging voltage according to the actual battery temperature to extend the battery life
  • Automatic self check
    Regularly self check the battery to ensure early detection of batteries that need to be replaced.
  • Intelligent battery management
    Obtain optimal battery performance, lifespan, and reliability through intelligent and precise charging technology.
  • Controllable external batteries
    Reduce the need for preventive maintenance by monitoring the normal operation and expected running time of external batteries
  • Compatible with Schneider Electric's lithium ion battery solution
    Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictablity and manageability.
    Click here for more details.
Other performance advantages
  • Upgradeable power capacity
    Allow for rapid upgrades in the future to reduce the cost of UPS being too large today
  • Front maintenance
    Simplify installation and UPS maintenance while minimizing space requirements.
  • Multiple cable entry points
    Provide flexibility for UPS placement in the computer room to facilitate cable installation to the terminal block
  • Capable of parallel redundancy
    Supply power to connected devices through multiple uninterruptible power supplies to improve system redundancy
  • Having parallel capability
    By simultaneously using multiple uninterruptible power supplies, the total power capacity can be increased.
  • Scalable runtime
    Allow for quick increase of more running time when needed
Sustainability
  • EU CoC for UPS
    Ensures that UPSs sold in the EU are highly efficient
Marketing Features
  • Parallel battery module
    Provide higher availability through redundant batteries
  • LSD monitor
    Provide a schematic overview of key data for operation guidance and troubleshooting on a color LCD touch screen
  • Full rated power supply kW equals kVA
    Reduce costs by eliminating the demand for power factor correction (PFC) loads in ultra large scale UPS systems
  • Upgradeable power capacity
    Allow for rapid upgrades in the future to reduce the cost of UPS being too large today
  • Input power factor correction
    By using small generators and wire connections, the need for external phase compensation units is eliminated, reducing installation costs
  • Modular design
    Through self diagnosis, on-site replaceable modules provide fast availability and reduce maintenance requirements
  • Compatible with generators
    When using the generator power supply, ensure a clean and uninterrupted power supply to protect the equipment
  • Parallel connection of power modules
    Immediate and seamless recovery from isolated module failures, enhancing availability
  • Can be configured as N+1 internal redundancy
    Allowing the configuration of one or more power modules than necessary to support connected loads, such redundancy provides high availability
usability
  • Modular design
    Through self diagnosis, on-site replaceable modules provide fast availability and reduce maintenance requirements
  • Parallel connection of power modules
    Immediate and seamless recovery from isolated module failures, enhancing availability
  • Battery Failure Notification
    Perform warning fault analysis on the battery in advance for timely preventive maintenance.
  • Compatible with generators
    When using the generator power supply, ensure a clean and uninterrupted power supply to protect the equipment
  • Can be configured as N+1 internal redundancy
    Allowing the configuration of one or more power modules than necessary to support connected loads, such redundancy provides high availability
  • network management
    Realize remote power management for UPS through the network.
  • Audible Alarm
    Provide notification of changes to the conditions of the mains and UPS power supply

output

  • Output power capacity

    1.6 MW/1.6 MVA

  • Maximum configurable power (watts)

    1.6 MW/1.6 MVA

  • rated output voltage

    400V 3PH

  • Output voltage annotation

    Can be configured for 3-phase rated output voltage of 380, 400, or 415 V

  • Output voltage distortion

    Less than 5% at full load

  • Output frequency (synchronized with the main frequency)

    50 Hz - Programmable+/-0.5/1/2/4/6/8%

  • Output frequency (asynchronous)

    50Hz +/- 0.1%, Rated 50Hz

  • Other output voltages

    380, 415

  • Peak load factor

    infinite

  • topology

    Delta Conversion Online

  • Waveform type

    sine wave

  • maximum output current

    2940

  • Output Connection
    (1) Hard Wire 5-wire (3PH+N+G) (backup battery)
    (1) Hard Wire 4-wire (3PH+N) (backup battery)
    (1) Hard Wire 4-wire (3PH+G) (spare battery)
    (1) Hard Wire 4-wire (3PH PEN) (backup battery)
  • bypass

    External static bypass

input

  • Rated input voltage

    400V 3PH

  • input frequency

    50 Hz - Programmable+/-0.5/1/2/4/6/8%

  • Input terminal type

    Hard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + PEN), Hard Wire 5-wire (3PH + N + G)

  • Working voltage range

    323 - 437 (380V), 340 - 460 (400V), 353 - 477 (415V)V

  • Adjustable input voltage range

    323 - 437 (380V), 340 - 460 (400V), 357 - 477 (415V)V

  • Number of power cords

    1

  • Other input voltages

    380, 415

  • Input power factor under full load

    0.99

Battery and running time

  • Type

    No internal battery - use external battery system

  • Automatically detectable and scalable delay time

    1

  • Optional battery

    Symmetra-MW-1600kW-400V

  • efficiency
    View efficiency chart

Communication and Management

  • Interface ports (multiple)

    Contact Closure , DB-9 RS-232 , RJ-45 10/100 Base-T , RS-485 , SYMWSUCBL

  • control panel

    Touch LCD screen user interface

  • Audible Alarm

    Audible and visible alarms prioritized by severity

  • emergency shutdown

    yes

Physical parameters

  • tall

    2032mm , 203.2cm

  • wide

    5486mm , 548.6cm

  • deep

    1067mm , 106.7cm

  • net weight

    6376.36kg

  • gross weight

    6576.36kg

  • Shipping height

    2235mm , 223.5cm

  • Shipping width

    6240mm , 624.0cm

  • Shipping depth

    1280mm , 128.0cm

  • colour

    Light grey (NCS 2703-G84Y)

  • Quantity of products on each transport pallet

    1.0

environment

  • operation temperature

    0 - 40 °C

  • Relative humidity at work

    0 - 95 %

  • Operating height

    0-99.9 meters

  • storage temperature

    -50 - 40 °C

  • Store relative humidity

    0 - 95 %

  • Storage height

    0-15000 meters

  • Noise that can be heard 1 meter away from the surface of the device

    75.0dBA

  • Online heat dissipation

    168960.0BTU/hr

  • Protection level

    IP 20

Compliance

  • Management organization certification

    CE, EN 50091-1, EN 50091-2, EN 50091-3, EN 60950, EN/IEC 62040-3, FCC Part 15 Grade A, IEC 60950, ISO 14001, ISO 9001, VFI-SS-111

  • Standard Warranty

    1-year repair or replacement service



施耐德SPupsapc.jpgSchneider APC uninterruptible power supply, precision air conditioning, cabinet, PDU, KVM and other integrated computer room power distribution!

APC电源