Suchuan supplies high-temperature and high-pressure steam nozzle flow meters, which have the characteristics of high temperature and pressure resistance, impact resistance, long service life, large measurement range, high measurement accuracy, and low pressure loss, and can be used for trade settlement. The standard nozzle is designed and manufactured according to the national standard GB/T2624-2006, and verified according to the national standard JJG640-94. No real flow calibration is required.
Product Details

Suchuan supplies high-temperature and high-pressure steam nozzle flowmeterSuitable for power plants, meets national 515 documents, and can issue supervision and inspection certificates

Product Features:

1. Simple structure and easy installation.

2. The pressure loss of the nozzle is smaller than that of the orifice plate, and the length of the straight pipe section is also required to be shorter.

3. No need for real stream verification, stable performance.

4. Can withstand high temperature, high pressure, and impact.

5. Corrosion resistance is better than orifice plates and has a longer lifespan.

6. High precision, good repeatability, and stable outflow coefficient.

7. The circular arc structure design can measure various liquids, gases, vapors, and various dirty media.

8. The overall forging processing technology has a high cost.

Main technical parameters:

1. Nominal diameter: 20mm ≤ DN ≤ 630mm.

2. Nominal pressure: PN ≤ 32Mpa.

3. Working temperature: -50 ℃ ≤ t ≤ 550 ℃.

4. Reynolds number range: When 0.30 ≤ β ≤ 0.44, 70000 ≤ ReD ≤ 107; When 0.44 ≤ β ≤ 0.8, 20000 ≤ ReD ≤ 107.

5. 喉径比: 0.30≤β≤0.80。

6. Accuracy: Level 0.5, Level 1.0, Level 1.5, Level 2.0.

7. Reference standards: GB/T2624-2006, JJG640-94.

8. Connection methods: flange connection, welding.

Measurement principle:

The measurement principle of a nozzle is based on the throttling principle of fluid mechanics. When the fluid filled in the pipeline flows through the nozzle, the flow velocity will locally contract at the nozzle, thereby accelerating the flow velocity and reducing the static pressure. As a result, a pressure drop or pressure difference is generated before and after the nozzle. The larger the flow rate of the medium, the greater the pressure difference generated before and after the nozzle. Therefore, the magnitude of fluid flow can be measured by measuring the pressure difference. Due to the circular arc contour structure of the nozzle, it has less pressure loss, requires a short straight pipe section, and has high accuracy.

Suchuan supplies high-temperature and high-pressure steam nozzle flowmeterFor more flowmeter products, please contact us!