1、 Brief introduction:
This photo introducesExplosion proof metal tube float flowmeterThe sensor structure in the photo is a vertical bottom in and top out type, and the sensor material is ordinary 304 stainless steel (optional 316, 316L, fluorine lined and other materials). It is powered by 24VDC and outputs 4-20mA. Users can choose the explosion-proof level ExdIICT6 and can also choose to use HART protocol. The sensor structure can be selected from multiple types according to the actual situation on site.
Overview:
Metal tube float flowmeterThe metal tube rotor flowmeter is a commonly used variable area flow measurement instrument in industrial automation process control. It has the characteristics of small size, large detection range, and easy use. It can be used to measure the flow rate of liquids, gases, and vapors, especially suitable for low flow rate and small flow measurement. For many years, metal tube float flowmeters have been widely used in industries such as petrochemicals, steel, electricity, metallurgy, light industry, food, pharmaceuticals, and water treatment due to their excellent performance, reliability, and good cost-effectiveness.
Flow meter type:
TFseriesmetal tube floatA flowmeter consists of a measuring tube (sensor) and an indicator (electronic converter). By selecting different forms of measuring tubes and indicators, it can be assembled into various forms of complete machines to meet the needs of the site.
TFThe series metal tube float flowmeter is divided into 5 types based on the direction of fluid inlet and outlet:Vertical type、horizontal type(divided into horizontal T-shaped, horizontal spring type), bottom in side out typeSide in and side out type、Side in and top out typeAnd each type has standard type, high temperature type, jacket type, etc.
Horizontal installation typeflow meterWhen the caliber is less than DN50 (inclusive), T-shaped structure is selected, and when it is greater than DN50, spring structure is selected.
Flow meter connection specifications: TF series metal tube float flow meter standard model adopts GB/T9119-2000 flange standard, and the flange standard can be made according to customer needs; Threaded connection and clamp connection can also be used.
Indicator selection:
Users can choose from on-site display type, battery powered type, electric remote transmission type, intrinsic safety explosion-proof type, explosion-proof type, or HART protocol type according to their actual needs. The detailed functional descriptions of various indicators are shown in the table below.
Indicator type |
Indicator Function Description |
M1type |
Local pointer indicates flow rate, no power supply, no 4-20mA remote transmission, optional flow alarm device, dial can choose instantaneous flow value or percentage scale value |
M3type |
On site digital display, battery powered, no 4-20mA remote transmission, non explosion proof. LCD displays instantaneous and accumulated flow, and on-site buttons are used to view and modify relevant parameters. The battery can be used for 6 months. When the T character appears on the display screen, the battery should be replaced (battery model ER26500, 3.6V, 7.5AH, -55 ℃~85 ℃). |
M4type |
Electric remote transmission, inherently safe design, explosion-proof mark Exd Ⅱ CT6, optional HART protocol function. DC24V power supply, on-site pointer indicating instantaneous flow and digital display of instantaneous and accumulated flow, two-wire 4-20mA output, panel with 4 buttons for viewing and modifying internal parameters. For detailed usage, please refer to page 18 |
M5type |
Electric remote transmission, explosion-proof design, explosion-proof mark Exd Ⅱ CT6, optional HART protocol function. DC24V power supply, on-site pointer indicating instantaneous flow and digital display of instantaneous and accumulated flow, two-wire 4-20mA output, panel with 4 buttons for viewing and modifying internal parameters. |
Features:
◆ Suitable for flow measurement of small caliber and low flow rate media ◆ Reliable operation, low maintenance, long service life
◆ Low requirements for straight pipe sections ◆ Wide range ratio 10:1
◆ Dual row LCD display, on-site instantaneous/cumulative flow display ◆ The indicator has a keyboard for easy operation and setting
◆ All metal structure, suitable for high temperature, high pressure, and highly corrosive media ◆ Non contact magnetic coupling transmission
◆ Can be used in flammable and explosive hazardous environments ◆ Optional DC power supply or battery power supply
◆ Equipped with data recovery, data backup, and power down protection functions ◆ Multi parameter calibration function
Technical Specifications:
Flow meter diameter DN15, DN25, DN50, DN80, DN100, DN150 (please consult with the manufacturer for other diameters)
◆ Flow range: Liquid: 1.0-150000l/h Gas: 0.05-3000m3/h (see flow table on page 11 for flow range)
Range ratio 10:1, 20:1 (special)
Accuracy level 1.5, 1.0 (special)
Pressure rating DN15, DN25, DN50: 4.0MPa (maximum 20MPa)
DN80、DN100、DN150:1.6MPa (zui 大: DN80:10MPa; DN100:6.4MPa; DN150:4.0MPa)
◆ Medium temperature standard: -30 ℃~+120 ℃, high temperature: 120 ℃~350 ℃
Power supply 24VDC (12-36VDC)
Output signal 4-20mADC (two-wire system), can be equipped with HART protocol
Output load 500 Ω (when powered by 24V)
◆ Local environmental temperature: -40 ℃~120 ℃ Remote transmission type: -30 ℃~60 ℃
Storage conditions: Temperature: -40 ℃~85 ℃ Humidity: ≤ 85%
◆ Connection method: flange connection, flange standard: GB/T9119-2000, users can choose (other connection methods can be negotiated with the manufacturer)
◆ Cable interface M20 × 1.5
◆ Shell protection IP65
Explosion proof mark: intrinsic safety type: ExiaICT6, explosion-proof type: ExdIICT6
The pressure loss is detailed in the flow chart
◆ 介质粘度 DN15:η<5mPa.s DN25:η<250mPa.s DN50~DN150:η<300mPa.s
◆ Liquid receiving material R1:304, 1Cr18Ni9Ti; Ro: 316, 0Cr18Ni12Mo2Ti;
RL:316L,00Cr17Ni14Mo2Ti; Ti: Titanium alloy; Rp: PTFE lining.
Magnetic filter:
If the medium contains ferromagnetic particles, a magnetic filter should be installed before the inlet of the flowmeter.