Switch controller pressure

NegotiableUpdate on 01/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The switch controller pressure adopts imported sensors and pressure sensitive components, and adopts an integrated junction box design. Equipped with dedicated wiring terminals and digital display. Easy to install, verify, and maintain. This series of products is suitable for various enterprises and institutions such as petroleum, water conservancy, chemical, metallurgical, power, light industry, scientific research, environmental protection, etc., to achieve measurement and control of fluid pressure. It is suitable for all-weather environments and various corrosive fluids in various occasions.
Product Details

HL-YBKG601

Switch controller pressureAdopting imported sensors and pressure sensitive components,Adopting an integrated junction box design. Equipped with dedicated wiring terminals and digital display. Easy to install, verify, and maintain. This series of products is suitable for various enterprises and institutions such as petroleum, water conservancy, chemical, metallurgical, power, light industry, scientific research, environmental protection, etc., to achieve measurement and control of fluid pressure. It is suitable for all-weather environments and various corrosive fluids in various occasions.

II Main Features

4 Display the current pressure value in digits.

Set up pressure switch action points on site.

The switch value can be set arbitrarily between zero and full degree.

The panel is equipped with switch point action light indicators for easy observation.

◆ Button calibration and on-site setting of various parameters, easy to operate..

2Road switch output, load capacity3A(resistive load).

◆ Analog output(4~20mA).

Attention:ifAL1H>AL1FThen thisSP1For the upper limit alarm mode, ifAL1H<AL1FThen thisSP1For the lower limit alarm mode, ifAL1H=AL1FThen thisSP1close. backlash=AbS(AL1H-AL1F).SP2Settings andSP1agreement.

2.Zero position reset:

In the zero pressure state, long press the position selection key, which is the middle button, and the longer you press, the more3-4It can be reset in seconds. Performing the reset operation again will restore the factory calibration state. The default reset value for factory status is07、 Precautions:

1Please connect the wires correctly according to the diagram. If connected in reverse, due to the protective measures adopted inside the instrument, there will be no signal output.

2This instrument is used in media that are non corrosive to stainless steel(Excluding special anti-corrosion types).

3The maximum pressure that can occur in the tested system cannot exceed the rated overload value. The back pressure end of the switch cannot be directly connected to conductive or corrosive liquids or gases. The air guide hole of the liquid level sealed air guide cable cannot be blocked.

4It is strictly prohibited to insert sharp and hard objects into the pressure output hole, and the diaphragm of the flush membrane transmitter cannot be touched by hands or anything else.

5This product is a precision primary measuring instrument, and it is strictly prohibited to randomly hit, forcefully clamp, disassemble, or poke the pressure hole with sharp metal tools.

6Instruments should be installed in ventilated, dry, non corrosive, and shaded areas as much as possible. If the on-site environment is harsh, appropriate measures should be taken to protect the instruments.

7If the output is abnormal, stop the machine for inspection. If it is a product quality problem, return it to our factory for repair and exchange along with the warranty repair card and user manual.

8Non professionals are not allowed to open the instrument or change the parameter settings.