Product Introduction: Three phase EPS Emergency Power Supply [Overview] EPS stands for Emergency Power Supply in English, which is an important component of modern building safety facilities
Product Introduction
Three phase EPS emergency power supply
[Overview]
EPS stands for Emergency Power Supply, which is an important component of modern building safety facilities. Generally, it is used as a power source for firefighting or production in emergency situations. For example, in high-rise buildings, shopping malls, hospitals, underground air defense projects and other places where there are many people, few exits, and limited natural light sources, once a fire occurs or the power grid is damaged, the light source disappears into darkness. At the same time, with many people and few exits, the consequences will be unimaginable. At the same time, the fire brigade may be unable to carry out rescue work due to a lack of power supply, which further exacerbates the severity of the disaster. If emergency power is available, it will greatly reduce losses, therefore emergency power plays an increasingly important role in ensuring the safety of modern society.
The emergency power supply for fire lighting is based on the requirements of the fire protection regulations for civil and industrial buildings, and adopts a complete design circuit and advanced production technology. All technical indicators have reached relevant international standards. Emergency lighting is an important component of modern building safety facilities. During normal lighting, emergency lighting is crucial to ensure the safety and rapid evacuation of personnel and rescue work in special situations such as power outages, power outages, or fire related power outages. This product can be used for high-rise buildings, shopping malls, hospitals, underground air defense projects, etc.
Fire linkage interface, RS232 interface.
Imported IPM intelligent power module assembly.
Patent technology, low no-load current.
American INTEL M80C196MC technology.
PLC monitoring, LCD night crystal display.
Isolate transformer output to reliably protect user equipment.
The emergency output is pure sine wave AC power with low harmonic content.
★ Important places such as squares, stations, parks, sports venues, exhibition centers, etc
★ Firefighting electricity: elevators/sprinkler pumps/rolling shutter doors, etc
★ High rise building electricity: elevators/water pumps/fans/central air conditioning, etc
★ Electricity consumption for financial system equipment
★ Military radar/airport/vehicle mounted mobile power station/civil defense passage/underground facilities
★ Hospital operating rooms/government buildings/large supermarkets/shopping malls
★ Industrial electricity: metallurgy/textile/petrochemical/power, etc
The lifespan of the host is over 20 years.
The maintenance free lead-acid battery can be reused 300-500 times.
Automatic instant switching, unmanned operation.
Stable performance, reliable operation, and easy maintenance.
Stable work voltage and frequency, no noise, no pollution, and no pollution when standing still.
Basic parameters of three-phase EPS power supply:
Specification Model
YJS2.2KW-18.5KW
YJS 22KW-50KW
YJS 55KW-500KW
input
voltage
380VAC±20%
phase number
Three phase four wire+ground wire
frequency
50Hz±10%
output
voltage
Normal time: Same mains voltage Emergency time: 380VAC ± 3%
frequency
Normal time: synchronized with the mains power. Emergency time: 50Hz ± 0.5%
waveform
Sine wave (THD ≤ 3%)
Output branch
Three ways (expandable)
Output branch type
Continuous, non continuous, fire linkage type
battery
Battery form
Sealed water free
Rated voltage
192VDC
324V DC
480VDC
Charging time
<24h
switch time
≤ 1.0ms (fast switching), ≤ 100ms (general load), ≤ 3.0-5.0s (variable frequency output motor load)
Emergency backup time
90 minutes (can be customized as needed)
overload capacity
120%60s; 150% 0.5s
protection function
Overvoltage, undervoltage, overcurrent, and short-circuit protection
communication
RS232/RS485, Communication protocol: Modbus
Noise (1m distance)
Normal: No noise Emergency: < 50dB
working environment
relative humidity
10-90%
ambient temperature
-20℃-40℃
sea wave
≤ 2000m (when > m, for every 100m increase, the power is reduced by 1%)
Adapt to load
Suitable for inductive loads and mixed inductive capacitive loads
Door opening method and incoming line method
Front door single open, rear door double open, bottom inlet and outlet cable (standard type)
Three phase EPS power supply size parameters:
Model
output power
EPS power supply size
Number of battery cabinets
Host weight KG
Battery weight KG
Yjs- 2.2 kw
2.2KW
450×750×1500
The battery is inside the EPS power cabinet
180
---
Yjs- 3.7 kw
3.7KW
450×750×1500
The battery is inside the EPS power cabinet
360
---
Yjs- 5.5 kw
5.5KW
450×750×1500
The battery is inside the EPS power cabinet
800
---
Yjs- 7.5 kw
7.5KW
630×800×2000
The battery is inside the EPS power cabinet
880
---
Yjs- 11 kw
11KW
630×800×2000
The battery is inside the EPS power cabinet
1050
---
Yjs- 15 KW
15KW
630×800×2000
The battery is inside the EPS power cabinet
240
1100
Yjs- 18.5 kw
18.5KW
630×800×2000
The battery is inside the EPS power cabinet
260
1100
Yjs- 22 kw
22KW
630×800×2000
1
280
1600
Yjs- 30 kW
30KW
630×800×2000
1
350
1600
Yjs- 37 kw
37KW
630×800×2000
2
380
2250
Yjs- 45 kw
45KW
630×800×2000
2
420
3200
Yjs- 55 kw
55KW
630×800×2000
2
480
3200
Yjs- 75 kW
75KW
630×800×2000
3
600
4800
Yjs- 93 kw
93KW
800×1000×2200
4
900
6300
Yjs- 110 kw
110KW
800×1000×2200
5
1000
6300
Yjs- 132 kw
132KW
800×1000×2200×2
6
1200
8000
Yjs- 160 kw
160KW
800×1000×2200×2
7
1300
9800
Yjs- 187 kw
187KW
800×1000×2200×2
8
1350
11000
Yjs- 200 kw
200KW
800×1000×2200×2
8
1380
11000
Yjs- 220 kw
220KW
800×1000×2200×2
8
1550
12000
Yjs- 250 kw
250KW
800×1000×2200×2
9
1580
14000
Yjs- 280 kw
280KW
800×1000×2200×2
10
2000
15000
Yjs- 315 kw
315KW
800×1000×2200×2
12
2200
18000
Yjs- 400 kw
400KW
800×1000×2200×2
13
2800
20000
Yjs- 500 kW
500KW
800×1000×2200×2
20
3600
26000
Product specifications and parameters
model
DMS1000-1.5
input
voltage
Single phase 220VAC ± 15%/300VDC ± 15%
frequency
47~63Hz
output
voltage
Adjustable from 0 to 1010V
current
Adjustable from 0 to 2A
power
1500W (overload capacity 1650W)
Source effect
Voltage regulator CV: ≤ 0.05% Steady current CC: ≤ 0.05%
Time drift
≤ 0.05% set value (after 8 hours of aging, under constant load conditions, constant ambient temperature, connected to Sense)
Load effect
Voltage regulator CV: ≤ 0.05%+10mV Steady current CC: ≤ 0.5%+10mA
Load transient recovery time
2ms (100% to 0% or 0% to 100%, voltage returns to within ± 1% of steady-state output)
efficiency
≥ 90% (standard AC input, full load)
ripple
CV
≤650mVp-p
CC
≤5mArms
Output display
LCD display (four display modes switchable)
Mode 1
Voltage and current display in 4-digit format: 9999 Power 5-digit display, display format: 99999
Mode 2
Voltage 6-digit display, display format: 199999; 5-digit display of current and power, with a display format of 99999
Mode Three
Current 6-digit display, display format: 199999/voltage, power 5-digit display, display format: 99999
Mode Four
Power 6-digit display, display format: 199999/voltage, current 5-digit display, display format: 99999
Display resolution (switch according to actual value size)
The display resolution automatically changes according to the actual value (taking 4-digit display as an example, X is the current value: X<10 is 0.001; 10 ≥ X < 100 is 0.01; 100 ≥ X < 1000=0.1) The highest resolution is 0.001
adjustment method
Manual panel
Multi functional button and encoder combination operation, supporting List dynamic programming output
Simulated Program Control
0-5V or 0-10V voltage signal (accuracy: 1% F.S.)
Digital Programming Control
RS-485 or USB communication interface, supporting Modbus communication protocol
External series and parallel operation
support
Set value resolution
voltage
0. 1V
current
0.001A
Set value accuracy
voltage
0.01%+0.05%F.S.
current
0.5%+0.5%F.S.
Read back value accuracy
voltage
0.01%+0.05%F.S.
current
0.5%+0.5%F.S.
protect
Protection against input undervoltage, output overvoltage, overheating, short circuit, etc
Cooling method
Air cooling
Intelligent fan control: The fan speed changes according to the actual current size
environmental conditions
Usage location: Only for indoor use. Working environment temperature: 0 ℃~45 ℃ Storage temperature: -20 ℃~70 ℃ Relative humidity: ≤ 90%