The volatile and aromatic terpene mixture obtained from pine trees rich in turpentine through different processing methods is called turpentine oil. The composition of turpentine varies with tree species, age, and place of origin. The main components of high-quality and first-class turpentine processed from pine resin are a-pinene, followed by b-pinene, limonene, etc. There are also small amounts of sesquiterpenes, namely longifolene and caryophyllene. Turpentine is an excellent organic solvent widely used in industries such as paint, desiccants, adhesives, etc. In recent years, turpentine has been increasingly used in the synthetic industry.The company follows the national standardGB/T12902-91 "Turpentine Analysis/Turpentine Testing Method Standard", in cooperation with domestic * * university research institutes, introducing key technologies and components, independently developing and designing domestically leadingTurpentine detection and analysis gas chromatograph GC-9860J, answerturpentineof**TestingAnalytical testingHaving an important leading position domestically.
1、 The main characteristics of the gas chromatograph GC-9860J for detecting and analyzing turpentine oil are:
1Fully computerized button operation, large screen LCD display, human-machine dialogue mode, easy operation;
2. Newly integrated digital electronic circuit with high control accuracy, stable and reliable performance, and temperature control accuracy up to 0 1℃.
3. Unique injection port design solves injection discrimination; The dual column compensation function not only solves the program drift caused by temperature rise, but also reduces the influence of background noise, which can have a lower detection limit.
4. The column box has a large volume, and the intelligent rear door opening system allows for infinitely variable air flow in and out, shortening the system's stable equilibrium time after program temperature rise/fall; Heating furnace system: (temperature range) ambient temperature+6℃~400℃.fiveStep program heating, heating rate 0-20℃/min; Incremental 0.1℃/Min allows users to recalibrate the furnace temperature and freely set the * * temperature. The temperature equilibrium time of the heating furnace is determined by the user.
5. Three types of injection systems can be installed simultaneously: packed column, capillary split/non split injection system (with diaphragm cleaning function); Two identical or different detectors can be installed simultaneously: hydrogen flame ionization detector (FID) and thermal conductivity detector (TCD). Optionalmultipleinjector.
6. Detector system: The flame ionization detector is easy to disassemble and install, making it easy to clean or replace the nozzle; High resistance single column thermal conductivity detector has high detection sensitivity and fast baseline stability (stable in 15 minutes); The input signal can be subjected to logarithmic amplification to reduce interference and improve sensitivity. TCD, ECD, NPD, and FPD can be optionally configured.
7. It has self diagnostic function upon startup, stopwatch function (convenient for flow measurement), running timer function, power-off storage protection function, keyboard locking function, and anti power mutation interference function.Easy to operate;
2、 Turpentine detection and analysis gas chromatograph GC-9860J technical indicators:
temperature control |
detectorFID |
|
Temperature control range: above room temperature6℃-400℃(Incremental)0.1℃) Cheng Ascending Order:5steps Cheng Sheng rate:0.1℃-50℃/min(increment0.1℃) |
Detection limit:≤8×10-12g/s(HEXADECANE) Baseline noise:≤2×10-13A/H Linear range:≥106 Stable time: less than20min |
detectorTCD |
DetectorFPD |
|
Sensitivity:≥5000mV·ml/mg(HEXADECANE) Baseline noise:≤30uV(The carrier gas is99.999The hydrogen gas) |
Detection limit:≤5×10-12g/s(N) Baseline noise:≤2×10-13A/H |
detectorECD |
DetectorNPD |
|
Detection limit:≤5×10-12g/s(N) (r-666) Baseline noise:≤2×10-13A/H |
Detection limit:≤5×10-12g/s(N) Baseline noise:≤2×10-13A/H |
3、 Instrument configuration for turpentine testing and analysis laboratory:
give birth to article name call |
model |
Main configuration |
quantity |
Gas phasecolour spectruminstrument |
GC-9860 |
Large screen display, equipped with hydrogen flame detector (FID), capillary injection system, five stage programmed temperature rise, intelligent rear door opening |
1 unit |
capillarycolour spectrumcolumn |
SE-30 |
30m*0.32 |
1root |
colour spectrumworkstation |
N2000 |
Dual channel with software includedExcluding computer printers |
1 set |
Nitrogen hydrogen air generator |
LCH-300E |
Nitrogen hydrogen air three gas integrated machine |
1 unit |
Gas purifier with valve |
GC-300 |
Three tube gas purifier with valve GC universal |
1 unit |
Our company's other analysis plans:
Gas chromatograph:
High purity gas analysis dedicated gas chromatograph┆Specialized gas chromatograph for trace moisture analysis┆Special for natural gas analysisgas chromatographyinstrument┆Special gas chromatograph for analysis of liquefied petroleum gas┆transformergas in oilAnalysis specific gas chromatograph┆Refinery gas analysis dedicated gas chromatograph┆Special gas chromatograph for packaging material product analysis┆PaintOrganic compound detection in Chinagas chromatograph┆Special gas chromatograph for product analysis of power plants and substations┆indoorIn the environmentTVOCDetection gas chromatograph┆Gas chromatograph for component analysis of Baijiu┆Gas chromatograph for the detection of essence and fragrance in Baijiu┆Detection of residual ethylene oxide in medical devices by gas chromatography┆Dimethyl ether detection chromatograph in liquefied gas┆Gas chromatograph for detecting alcohol content in blood using headspace method┆Drug solvent residue detection gas chromatograph┆Chromatograph for detecting organophosphate pesticide residues in food┆Chromatograph for detecting organochlorine pesticide residues in food┆Chromatograph for detecting pesticide residues such as hexachlorocyclohexane and DDT in food┆Natural gas component analysis gas chromatograph┆Liquefied petroleum gas component analysis gas chromatograph┆ Liquefied gas dimethyl ether detection chromatograph ┆ Dimethyl ether purity analysis chromatographAnalytical chromatograph for oxygen-containing compounds and aromatic hydrocarbons in automotive gasoline┆Tobacco and tobacco packaging materialsVOCSDetection gas chromatograph┆Turpentine detection gas chromatograph┆ Gas chromatograph for underground gas analysis in coal mines ┆ Gas chromatograph for detecting non methane total hydrocarbons in indoor environments ┆Analysis of sulfur-containing/nitrogen-containing/oxygen-containing compoundsgas chromatograph┆ Analysis of Food Additives Gas Chromatography ┆Fatty acids in vegetable oilsanalysisgas chromatograph┆ Turpentineanalysisgas chromatograph┆ Analysis of tar C6H6 series by gas chromatography ┆ Analysis of alcohols and ethers in gasoline by gas chromatography ┆Detection of solvent residues in vegetable oilgas chromatograph Gas chromatograph for detection of solvent residues in printing and packaging ∨ Gas chromatograph for analysis of pharmaceutical intermediates ∨ Gas chromatograph for detection of No. 6 solvent in edible oil ∨ Gas chromatograph for detection of plasticizers in Baijiu ∨ Gas chromatograph for detection of benzene series in indoor air ∨Online automatic gas analysis dedicated gas chromatograph┊Helium ion high-purity gas analysis dedicated gas chromatograph┆ Fully automatic microcomputer reverse controlgas chromatographNew generation EPC controlled gas chromatograph
effectiveLiquid chromatograph:
twoMeta gradient effective liquid chromatography┆Special liquid chromatography instrument for melamine detection and analysis┆ Traditional Chinese Medicine TestingEffective liquid chromatography instrument┊High pressure gradient liquid chromatography│Economical, practical and effective liquid chromatography instrument┆feedTesting specificeffectiveLiquid chromatograph┆Special liquid chromatography instrument for analysis of arachidonic acid in honey┆Special liquid chromatography instrument for paint and coating analysis┆Special liquid chromatography instrument for drug and pesticide residues┆ Vitamin detection in feed by liquid chromatography ┆ Traditional Chinese medicine decoction piece detection by liquid chromatography
Lu ChuangThe clothingaffairAdvantages:
1. The technical indicators of the company's products strictly comply with the requirements of technical documents, and the product quality meets the requirements of relevant national standards.
2、The product is installed, debugged, and trained by technical personnel or provided with free telephone guidance.
3. After the product is accepted as qualified,a yearDuring the warranty period, except for human damage factors, our company guarantees free maintenance;Lifetime maintenance of equipment, charging only cost for vulnerable parts, providing free technical support and discounted accessory supply.
4.Lu ChuangofserviceEngineers have received training in chemical analysis, instrument maintenance, and upkeep. They can perform maintenance and repair on various components to ensure that your instrument runs smoothly and can solve your problems quickly
5Timely telephone technical support - experts in troubleshooting answer your calls and provide timely solutions to problems
6. * * * * Service----Lu ChuangProvide high-quality services within the scope of * * * *,Online Instrument Problem Answering:QQ:377502153
7Flexible response time - after phone repairWithin 24 hourstimelyGuidance or within 72 hoursDoor to door problem-solving.
8There are free and irregular chromatography training courses every year The content includes chromatographic principles、analysis、application,Technical instrument operation.Product details can be obtained throughhttp://www.lcsepu.comqueryorPhone: 0632-5080618/Conduct inquiry and consultation.