VICTOR 4110D Three Channel DC Resistance TesterIt is a commonly used instrument for testing and measuring grounding resistance. It adopts a new type of variable frequency AC power supply, dual frequency measurement technology, ultra large touchable color screen, and microprocessor technology to meet the impedance requirements of two-wire, three wire, and four wire tests. At the same time, it can measure parameters such as soil resistivity, step voltage, distributed potential, contact voltage, and current phase angle. Suitable for telecommunications, power, meteorology, computer rooms, oil fields, power distribution lines, iron tower transmission lines, gas stations, factory grounding grids, lightning rods, etc., in compliance with the standards for testing instruments for power substations and lightning protection devices. The instrument testing is characterized by precision, speed, simplicity, stability, and reliability.











VICTOR 4110D Three Channel DC Resistance TesterAlso known as power frequency grounding resistance tester, grounding resistance meter, etc., it is a commonly used instrument for inspecting and measuring grounding resistance. It adopts a new type of variable frequency AC power supply, dual frequency measurement technology, ultra large touchable color screen, and microprocessor technology to meet the impedance requirements of two-wire, three wire, and four wire tests. At the same time, it can measure parameters such as soil resistivity, step voltage, distributed potential, contact voltage, and current phase angle. Suitable for telecommunications, power, meteorology, computer rooms, oil fields, power distribution lines, iron tower transmission lines, gas stations, factory grounding grids, lightning rods, etc., in compliance with the standards for testing instruments for power substations and lightning protection devices. The instrument testing is characterized by precision, speed, simplicity, stability, and reliability.
The 4110D three channel DC resistance tester outputs an open circuit rated voltage of 27V and a maximum short-circuit current of 20A. The microprocessor control and automatic dual frequency technology can accurately measure and calculate the grounding impedance value at 50Hz power frequency under strong interference conditions, and the large screen display is clear at a glance. Simultaneously store 500 sets of data, with a resistance measurement range of 0.1u Ω to 5000 Ω. Measurement data can be printed using a thermal printer, exported from a USB flash drive and computer software.
Range and accuracy
| measure current | measurement range | precision | resolution |
| 20A | 0.0001~1.0000mΩ | ±0.2%FS±10dgt | 0.1uΩ |
| 1.001~10.000mΩ | ±0.2%FS±10dgt | 0.001mΩ | |
| 10.01~100.00mΩ | ±0.2%FS±10dgt | 0.01mΩ | |
| 100.1~1000.0mΩ | ±0.2%FS±10dgt | 0.1mΩ | |
| 10A | 0.0001~1.0000mΩ | ±0.2%FS±10dgt | 0.1uΩ |
| 1.001~10.000mΩ | ±0.2%FS±10dgt | 0.001mΩ | |
| 10.01~100.00mΩ | ±0.2%FS±10dgt | 0.01mΩ | |
| 100.1~1000.0mΩ | ±0.2%FS±10dgt | 0.1mΩ | |
| 5A | 0.001~10.000mΩ | ±0.2%FS±10dgt | 0.001mΩ |
| 10.01~100.00mΩ | ±0.2%FS±10dgt | 0.01mΩ | |
| 100.1~1000.0mΩ | ±0.2%FS±10dgt | 0.1mΩ | |
| 1.001~5.000Ω | ±0.2%FS±10dgt | 0.001Ω | |
| 2A | 0.001~10.000mΩ | ±0.2%FS±10dgt | 0.001mΩ |
| 10.01~100.00mΩ | ±0.2%FS±10dgt | 0.01mΩ | |
| 100.1~1000.0mΩ | ±0.2%FS±10dgt | 0.1mΩ | |
| 1.001~10.000Ω | ±0.2%FS±10dgt | 0.001Ω | |
| 0.5A | 0.01~100.00mΩ | ±0.2%FS±10dgt | 0.01mΩ |
| 100.1~1000.0mΩ | ±0.2%FS±10dgt | 0.1mΩ | |
| 1.001~10.000Ω | ±0.2%FS±10dgt | 0.001Ω | |
| 10.01~50.00Ω | ±0.2%FS±10dgt | 0.01Ω | |
| 0.2A | 1.001~10.000Ω | ±0.2%FS±10dgt | 0.001Ω |
| 10.01~100.00Ω | ±0.2%FS±10dgt | 0.01Ω | |
| 100.1~1000.0Ω | ±0.25%FS±15dgt | 0.1Ω | |
| 1001~5000Ω | ±0.3%FS±20dgt | 1Ω | |
| Temperature characteristics: Use within the temperature range plus testing accuracy of x 0.1/℃. (Outside of 18 ℃ to 28 ℃) For example, at 8 ℃: ± 0.2% FS ± 10dgt (basic accuracy)+0.1 × 10 (temperature difference) × (0.2% FS+10dgt) = ±0.4%FS±20dgt | |||
technical indicators
| Function | Mainly used for measuring the DC resistance of transformers, the winding resistance of transformers, the conductivity of ground grid connections, the wire resistance of cables, the contact resistance of switches, connectors, relays, coils, motors, transformer windings, metal riveting resistance, connection resistance testing between metal components, low value resistance testing, contact resistance testing, etc. |
| resistance range | 0.1uΩ-5000Ω |
| Power supply | AC 220V 10A (50Hz) |
| Rated measurement power | 1200W |
| Backlight | Adjustable backlight brightness |
| measurement method | Four-line test |
| Short circuit current output | 0.2A, 0.5A, 2A, 5A, 10A, 20A (6-speed setting) |
| Maximum short-circuit current | DC 20A±10% |
| Maximum no-load voltage | DC 27V±15% |
| display screen | 7-inch touch color screen |
| overload protection | have |
| Automatic discharge | have |
| USB flash drive interface | Copy and save data |
| USB port | Equipped with a USB interface, it can be connected to an upper computer to access data |
| Measurement indication | Measurement progress display, real-time measurement display |
| instrument size | Length, width, and height: 400mm × 300mm × 210mm |
| Standard test line length | 4 pieces (2 pieces each of red 5m, blue 5m, yellow 5m, green 5m) |
| Built in thermal printer | |
| Printing paper specifications | 57*40mm |
| data storage | 500 sets of measurement data storage |
| Data retrieval | have |
| Overflow display | Overscale overflow function: "OL" symbol display |
| Power consumption | Standby: ≤ 110W/Measurement: ≤ 1500W |
| Quality | Instrument: 7 kg |
| Working temperature and humidity | -10℃~40℃; Below 80% RH |
| Storage temperature and humidity | -20℃~60℃; Below 70% RH |
| insulation resistance | Above 10M Ω (500V between circuit and casing) |
| Voltage resistance | AC 3700V/rms (between circuit and casing) |
| electromagnetic properties | IEC61010-4-3, Wireless frequency electromagnetic field ≤ 1V/m |