Voltage and current calibrator VICTOR 06

NegotiableUpdate on 12/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The VICTOR 06 voltage and current calibrator is a portable device designed for on-site circuit debugging. It can provide 24V circuit power supply and measure circuit current, making it easy to debug on-site transmitters; The active/passive current output function facilitates the debugging of systems such as PLC and DCS.
Product Details

Voltage and current calibrator VICTOR 06It is a portable device designed for on-site circuit debugging. It can provide 24V circuit power supply and measure circuit current, making it easy to debug on-site transmitters; The active/passive current output function facilitates the debugging of systems such as PLC and DCS.

Voltage and current calibrator VICTOR 06It has been widely applied in fields such as petrochemicals, biopharmaceuticals, industrial automation, colleges and research institutions.

Basic characteristics of the product
1. Input measurement characteristics

*Basic functions: DC voltage DCV, DC current DCI.
*The highest measurement accuracy is 0.05%, and the measurement display is 5 digits.
*Measurement rate: 2-3 times per second.
*Loop detection function, internal 24V circuit power supply, and simultaneous measurement of current.
*MA has a percentage display mode.

2. Analog output characteristics

*Output function: DC voltage DCV, DC current DCI.
*The highest output accuracy is 0.05%, and the output is displayed as 5 bits.
*The output setting can be manually adjusted by bit.
*DCI output includes active output (internal 24V power supply) and passive output (external 24V power supply).
*MA has a percentage display mode.
*When outputting DCI, manual stepping and automatic waveform output functions can be provided.
The manual step output includes: 25% step and 100% step.
The automatic wave output includes: automatic stepping, sawtooth wave, triangular wave, and the working parameters of the automatic waveform can be configured.

3. Internally provide 24V circuit power supply.
4. Allow simultaneous measurement and output of process signals, as well as simultaneous display of input measurement values and output settings.
5. Maintain the settings function, including:

Automatic shutdown, automatic backlight, flashlight, etc

6. Other

*Segment code LCD screen display, white backlight.
*LED flashlight illumination.
*Powered by 3 No. 5 alkaline batteries, the battery compartment door allows for easy battery replacement and low battery detection.
*Compact, sturdy, and reliable, suitable for on-site use.
*Users can choose a high suction magnetic strap.


2、 Basic functions and performance (technical indicators) of the product
Analog output function[Applicable within one year after calibration, 23 ℃± 5 ℃, 20-70% RH, accuracy=± (% set value+word)]

function range output range resolution precision Remarks
DC voltage
DCV
10V -1.000V~11.000V 0.001V 0.05%+2mV Maximum output current 5 mA
(Output ≤ 10V)
direct current
DCI Active
20mA 0.000mA~20.000mA 0.001mA 0.05%+4uA 20mA maximum load 1k Ω
direct current
DCI Passive
-20mA 0.000mA~-20.000mA 0.001mA 0.05%+4uA 20mA maximum load 1k Ω

Other features:
*Uncertainty includes standard uncertainty, lag, nonlinearity, repeatability, and typical long-term stability during the mentioned period (K=2).
*Maximum applied voltage at the output end: about 30Vpk; Maximum applied current at the output end: approximately 25mA
*Output protection: 100mA fuse.
*Temperature coefficient: 0.1 x basic accuracy/℃ (temperature range<18 ℃ or>28 ℃)

Input measurement function[Applicable within one year after calibration, 23 ℃± 5 ℃, 20-70% RH, accuracy=± (% set value+word)]

function range input range resolution precision Remarks
DC voltage
DCV
100mV -110.00mV~100.00mV 0.001mV 0.05%+0.03mV
1V -1.1000V~1.1000V 0.00001V 0.05%+0.3mV
30V -35.000V~35.000V 0.001V 0.02%+2mV
direct current
DCI
30mA -35.000mA~35.000mA 0.001mA 0.02%+4uA
Circuit power supply
LOOP
24V

±10%


Other features:
*Uncertainty includes standard uncertainty, lag, nonlinearity, repeatability, and typical long-term stability during the mentioned period (K=2).
*Display refresh rate: 2-3 times/second.
*Maximum applied voltage at the input end: 60Vpk.
*Input protection: 100mA fuse.
*Input common mode rejection: 50Hz/60 Hz>80 decibels; Input serial mode suppression: 50Hz/60 Hz>40 decibels
*Temperature coefficient: 0.1 x basic accuracy/℃ (temperature range<18 ℃ or>28 ℃)

3、 General characteristics of the product
*Working temperature and humidity: 0 to 50 º C ≤ 80% RH, no condensation; 40 to 50 º C ≤ 70% RH.
*Storage temperature and humidity: -25 to 60 º C ≤ 90% RH, no condensation.
*Electrical safety: EN61010-1:2001
Voltage endurance: AC3540V (50/60Hz)/5 seconds between the terminal and the casing.
Insulation impedance: DC1000V/100M Ω or greater between the terminal and the casing.
*Electromagnetic compatibility (EMC): EN61326-1:2006
Meets performance criterion 2, which means that the functionality and performance are temporarily reduced or lost, but can be restored on their own.
*Protection level IP40.
*Vibration and Drop: IEC 60068-2-64:2008, IEC 60068-2-32:2008
Random, 2g, 5-500Hz; 1-meter drop test.
*CE certification.
*Quality standards: Developed, designed, and manufactured in accordance with TUV ISO 9001.
*Calibration cycle and preheating time:
To ensure the accuracy of this table, its calibration cycle is one year
The startup preheating time is greater than 30 minutes
*Instrument display and buttons
Segment code LCD display, white backlight
Adopting silicone rubber buttons
*Instrument power supply
Powered by 3 5th alkaline batteries