Welcome Customer !

Membership

Help

Xi'an Shengli Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

VICTOR 8265 Smart Desktop True RMS Multimeter

NegotiableUpdate on 12/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The VICTOR 8265 intelligent desktop true RMS multimeter has display resolutions of 4-1/2 bits, 5-1/2 bits, and 6-1/2 bits, with the highest display reading value; #177; 1200000 words, with a basic DC voltage accuracy of up to 0.0035%.
Product Details

VICTOR 8265 Smart Desktop True RMS MultimeterThere are 4-1/2 bit, 5-1/2 bit, and 6-1/2 bit display resolutions, with a maximum display reading of ± 1200000 words and a basic DC voltage accuracy of up to 0.0035%.

VICTOR 8265 Smart Desktop True RMS MultimeterProduct Features:

The instrument has display resolutions of 4-1/2 bits, 5-1/2 bits, and 6-1/2 bits, with a maximum display reading of ± 1200000 words.
2. The accuracy of basic DC voltage is as high as 0.0035%.
3. Input measurement function

① DC voltage, AC voltage, DC current, AC current measurement, resistance, capacitance measurement, frequency measurement
② On/off, diode testing, thermocouple, thermistor temperature measurement
③ Relative value measurement (REL_%), maximum value, minimum value, average value measurement (MAX/MIN/AVG)
④ Measurement Comparison Function (COMP)

4. In the basic measurement function, the instrument measurement work can be configured:

① Manual/automatic measurement;
② ADC integration time, input impedance, automatic zero calibration;
③ Unit of temperature measurement and cold end compensation

5. Sampling timeThe fastest is 0.125 PLC (400 times/second).
6. Resistance measurement adopts 2-wire or 4-wire measurement, and 4-wire measurement can be used to eliminate the influence of lead resistance.
7. Communication measurement is true RMS measurement.
① AC voltage measurement bandwidth: 20Hz to 100kHz.
② AC current measurement bandwidth: 20Hz to 30kHz.
8. Decibel measurement with reference impedance ranging from 1 to 2400 Ω can be selected.
9. Measurement with 8 graduated thermocouples: K, E, J, T, B, S, N, R.
10. Two scale thermal resistance measurements: PT100, PT1000.
11. Measurement comparison function, with pre-set limit range (upper/lower limit).
12. The instrument has four measurement triggering working modes, which control the instrument's measurement work through triggering work.
13. The multimeter has a data recording function, and the internal memory can independently store up to 10000 sets of measurement data. The recorded data can be read and processed by the computer.
14. The instrument communicates with the computer through USB and RS232 interfaces. Supports standard SCPI commands and enables remote control of instruments through device driver software.
15. Bright and clear large screen VFD dual display, convenient and fast key operation.

Basic functions and performance (technical indicators) of the productAccuracy=± (% reading+% range)

function range scope resolution precision Remarks
DC voltage
DCV
100.0000mV -120.0000mV~120.0000mV 0.1uV 0.0065%+0.005% Input impedance: 10 M Ω or>10 G Ω
1.000000V -1.200000V~1.200000V 1uV 0.005%+0.0007%
10.00000V -12.00000V~12.00000V 10uV 0.0035%+0.0005%
100.0000V -120.0000V~120.0000V 0.1mV 0.0045%+0.0006% Input impedance: 10 M Ω
1000.000V -1000.000V~1000.000V 1mV 0.0055%+0.0015%
direct current
DCI
10.00000mA -12.00000mA~12.00000mA 0.01uA 0.015%+0.005% Sampling resistance: 10 Ω
100.0000 mA -120.0000mA~120.0000mA 0.1uA 0.015%+0.005% Sampling resistor 1 Ω
1.000000A -1.200000A~1.200000A 1uA 0.05%+0.008% Sampling resistance 0.01 Ω
10.00000A -10.00000A~10.00000A 10u A 0.25%+0.04%
resistance
OHM
100.0000Ω 0~120.0000Ω 0.1mΩ 0.01%+0.004% Excitation current: 1mA
1.000000KΩ 0~1.200000KΩ 1mΩ 0.01%+0.001% Excitation current: 1mA
10.00000KΩ 0~12.00000KΩ 10mΩ 0.01%+0.001% Excitation current: 0.1mA
100.0000KΩ 0~120.0000KΩ 0.1Ω 0.01%+0.001% Excitation current: 0.01 mA
1.000000MΩ 0~1.200000MΩ 0.01%+0.001% Excitation current: 1uA
10.00000MΩ 0~12.00000MΩ 10Ω 0.04%+0.001% Open circuit voltage is about 7V
100.000MΩ 0~100.000MΩ 1KΩ 0.8%+0.01% Open circuit voltage is about 7V
frequency
FREQ

3~5 Hz 0.1mHz~
100mHz
0.1% 1. Level sine wave
2. Sensitivity: 5%~100% of full scale

5~10 Hz 0.05%

10~40 Hz 0.03%

40Hz~100kHz 0.01%
capacitance
CAP
10.000nF 0~10.000 nF 1pF 1%+0.8%
100.00nF 0~100.00 nF 10pF 1%+0.5%
1 .0000uF 0~1.0000 uF 0.1nF 1%+0.5%
10.000uF 0~10.000 uF 1nF 1%+0.5%
100.00uF 0~100.00 uF 10nF 1%+0.5%
1.0000mF 0~1.0000 mF 0.1uF 1%+0.5%
10.000mF 0~10.000 mF 1uF 1%+0.5%
thermocouple
TC

K/E/J/R/S/T/B/N 0.1℃/1℃ 1.5℃ Please refer to the instruction manual for detailed indicators
thermocouple
RTD

PT100/PT1000 0.1℃ 0.4℃
Conductivity measurement 100.00Ω 0~120.00Ω 10mΩ 0.05%+0.05%
Diode testing 10.000V 0~5.500V 1mV 0.05%+00.5% Excitation current: 1mA/6V


Accuracy=± (% reading+% range)

function range frequency band precision Remarks
AC voltage ACV 100mV 20Hz~50Hz 0.8+0.05 Input impedance: 1 M Ω± 2%, parallel capacitance<100pF
50Hz~100Hz 0.1+0.03
100Hz~10kHz 0.05+0.03
10kHz~30kHz 0.05+0.05
30kHz~50kHz 0.5+0.05
50kHz~100kHz 0.8+0.5
1V~100V 20Hz~50Hz 0.8+0.05
50Hz~100Hz 0.1+0.03
100Hz~10kHz 0.05+0.03
10kHz~30kHz 0.05+0.05
30kHz~50kHz 0.5+0.05
50kHz~100kHz 0.5+0.5
750V 20Hz~50Hz 0.8+0.05
50Hz~100Hz 0.1+0.03
100Hz~10kHz 0.05+0.08


function range frequency band precision Remarks
AC current ACI 10mA~100mA 20Hz~50Hz 0.5+0.05 Shunt resistor
10mA:10Ω
100mA:1Ω
50Hz~5kHz 0.1+0.03
5kHz~10kHz 0.3+0.03
10kHz~30kHz 0.5+0.05
1A 20Hz~50Hz 0.5+0.05 Shunt resistor
0.01Ω
50Hz~100Hz 0.2+0.05
100Hz~1kHz 0.3+0.05
1kHz~5kHz 0.8+0.2
10A 20Hz~50Hz 0.5+0.05 Shunt resistor
0.01Ω
50Hz~100Hz 0.5+0.05
100Hz~1kHz 0.5+0.05
1kHz~5kHz 0.8+0.05


一般特性:
① Working temperature and humidity: 0 to 50 º C ≤ 80% RH, no condensation; 40 to 50 º C ≤ 70% RH.
② Storage temperature and humidity: -25 to 60 º C ≤ 90% RH, no condensation.
③ Compliant with safety standards: EN61010-1; 1995, EN61010-2-031; one thousand nine hundred and ninety-five
④ Electromagnetic compatibility (EMC): EN61326-1:2006
⑤ Vibration and Drop: IEC 60068-2-64:2008, IEC 60068-2-32:2008
⑥ Instrument power supply
220V ± 10% AC, power frequency: 50Hz or 60Hz, power: approximately 18W.
⑦ Size and weight
245 × 220 × 82 (mm), approximately 2kg
⑧ Attachment
Test probe 1 payment
1 power cord
1 USB cable
One DB/9 serial port cable
1 manual