1product overview
This device, also known as the wire damage test device, complies with the requirements of GB2099, GB1314.3, GB16915, IEC60669, IEC60884 and other standards. It is mainly used to determine whether the threaded clamping type terminal meets the requirements of no excessive damage to the wire when clamped, and to test whether the non threaded terminal can withstand the mechanical stress that occurs during normal use. When in use, the test times can be pre-set, and the machine will automatically stop when the set value is reached, accompanied by an audible alarm signal.
The main difference of this machine is that it is a dual station wire damage test, equipped with tension test weights, which can simultaneously test two different and the same wires.
2、 Technical parameters
1. Working power supply: AC 220V 50HZ
2. Workstation: Two workstations
3. Working speed: 10 ± 2 revolutions per minute
4. Count range: 0-9999, default 150 times (15 minutes)
5. Rotating weights: two sets each of 0.3,04,0.7,0.9,1.4,2.0kg and 30,40,50,60N weights
6. Rotation diameter: 75mm
7. The hole diameters of the wire sleeves are 6.5, 9.5, 13, and 14.5mm, respectively
8. Height distance: 260, 280, 300, 320mm
9. Dimensions: 1000mm X400mm X1300mm
10. Table of optional parameters for wires, wire sleeves, height, and rotating weights
Wire cross-sectional area mm ² |
Diameter of casing hole mm |
Height mm |
Weight kg corresponding to the wire |
0.5 |
6.5 |
260 |
0.3 |
0.75 |
6.5 |
260 |
0.4 |
1.0 |
6.5 |
260 |
0.4 |
1.5 |
6.5 |
260 |
0.4 |
2.5 |
9.5 |
280 |
0.7 |
4.0 |
9.5 |
280 |
0.9 |
6.0 |
9.5 |
280 |
1.4 |
10.0 |
9.5 |
280 |
2.0 |
16.0 |
13.0 |
300 |
2.9 |
25.0 |
13.0 |
300 |
4.5 |
35 |
14.5 |
320 |
6.8 |
|
1. Tolerance for height H: ± 15mm. 2. If the diameter of the sleeve hole is too small to accommodate wires without tight ties, a larger sleeve hole can be used instead. | |||
11. Table of supporting parameters for wires and tension weights
The terminal can connect wires with a cross-sectional area of mm ² |
0.5~1 |
0.75~1.5 |
1.5~2.5 |
2.5~4 |
4~6 |
6~10 |
10~16 |
16~25 |
Tensile force N |
30 |
40 |
50 |
50 |
60 |
80 |
90 |
100 |