YCS-7000S/V3.0 Building Equipment Management System
Building equipment monitoring systemAir conditioning and ventilation system, water supply and drainage system, power supply and distribution system, lighting system, and elevator subsystemPerform equipment operation andMonitoring and Control of Building Energy ConsumptionThe system adopts intelligent equipment that integrates power distribution, control, energy conservation, safety alarm, and fieldbus communication. Air conditioning unit for buildings,Efficient monitoring and management of mechanical and electrical equipment such as ventilation, water supply and drainage, elevators, and public lighting.
The system fully meets the requirements of various building electrical energy-saving design, green building energy-saving design, and building intelligent design acceptance.
System Introduction
The building equipment monitoring system has an intuitive and easy to understand user interface. This system consists of a supervision workstation, on-site controllers, end sensors, and actuators, and belongs to a building intelligent system platform that combines centralized supervision and distributed control. The system includesIntelligent lighting control system, ventilation monitoring system, water supply and drainage monitoring system, elevator monitoring system, HVAC monitoring system, air quality monitoring systemEach subsystem supports independent operation and integrated control, meeting the requirements of includingShopping malls, office buildings, venuesThe demand for equipment monitoring in large public buildings.
Building equipment monitoringReal time monitoring of buildings by the systemCold and heat sources, air conditioning/fresh airVentilation, water supply and drainage, elevator systemIntelligent lightingSupport system level startup and shutdown. For end devices such as fresh air units and fan coil units, according toASHRAEEfficiently control the range of human comfort standards and provide energy-saving optimization strategies.
For third-party systems and devices, support system integration for comprehensive device management through standard communication protocols and interfaces.
Building equipment monitoring system(BAS)achievable:
(1)reduce energy consumptionexpenditure
Through the intelligent start stop function of the system, non essential equipment can be automatically shut down during non working hours, reducing energy waste, timely detecting equipment energy consumption waste, and reducing energy consumption
(2)Improve energy utilization efficiency
Building equipment monitoring system, combined with weather, personnel, indoor environment and other building conditions, optimizes the operation status of valves, water pumps, fans and other equipment, improves equipment operation efficiency, and increases energy-saving benefits.
(3)Reduce building operating costs and improve operational efficiency
By using the building equipment monitoring system to obtain the operation status of various mechanical and electrical equipment inside the building, the efficiency of personnel inspection is greatly improved, and labor costs are saved;Simultaneously enhance fault response capability and promptly eliminate potential hazards. By optimizing the balancing algorithm, it is possible to balance the wear and tear of parallel backup equipment and extend its service life.
For more product information or pricing, please call our company.
Manager 138→ 9183 → 4587 (VX Same Number)
138 ❤ 9183 ❤4587
We are dedicated to serving you wholeheartedlyProvide comprehensive and professional solutions and product quotation services!!!
System product configuration
YCS-7000S/V3.0Building Equipment Management System
Network EngineYCS-7002WG
Regional Controller
DDCcontroller
DDCcontrollerYCS-1664C
DDCcontrollerYCS-1244C
DDCcontrollerYCS-842C
Expansion module:
I/Oextension moduleYCS-1680IO
I/Oextension moduleYCS-1244IO
I/Oextension moduleYCS-840IO
DDCAutomatic control box
DDCcontrol boxCity 500 * 600 * 200
DDCcontrol boxCity 600*800*200
DDCcontrol boxPANLE-L 800*1000*200
DDCcontrol boxPANLE-XL 800*1200*200
terminal device
Indoor temperature and humidity sensor
level switch YZY03
Differential pressure switch YZDS1
water flow switchYZFS25
antifreeze switchYZCL3
Duct type temperature sensor YZTA11
Duct type temperature and humidity sensor YZTH2A100
Water tube temperature sensor YZTPT1
Water tube differential pressure sensor YZPA421
Outdoor temperature and humidityYZTH2A300
Switch air valve actuator Yza10003
Adjust the air valve actuator Yza10011
Duct CO2 Duct Type Carbon Dioxide Sensor YZCD010
Multi in one detector YZQ0B10 (CO2, PM2.5, formaldehyde,...) TVOC)
Type: Environmentally friendly electrochemical gas sensor;
Range: 0~2000ppm/0~500 μ g/m3/0~5ppm/0.001~2ug/m3;
Resolution ≤ 0.01ppm/0.001ug/m3;
LCD (Liquid Crystal Display)
精度0.01 ppm/0.001ug/m3/1ppm/1μg/m3;
RS485 communication
Power supply: 24VDC