1. Before use, the appropriate electrode constant should be selected based on the conductivity value of the tested water sample. Using beyond the measurement range of this electrode can result in significant errors or even render it ineffective.
2. Before use, the constant of the conductive electrode should be entered correctly into the secondary table.
3. After using the electrode for a period of time, it should be cleaned. The method is to soak the electrode in a 3% HCl (dilute hydrochloric acid) solution for two minutes, and then rinse with purified water.
4. If the electrode is installed in a submerged manner, be careful not to let water enter the top of the electrode and the wire. The general method used is to thread the electrode lead out of the protective sleeve, and then connect the thread on the top of the electrode to the thread on the protective sleeve with a tape.
Name Electrode constant Structure and Materials measurement range Applicable Temperature withstand pressure Online conductive electrode k-0.01 Cylindrical, titanium alloy, with temperature compensation 0~20us/cm 0~120℃ 1MPa Online conductive electrode k-0.1 Cylindrical, titanium alloy, with temperature compensation 0~200us/cm 0~120℃ 0.8MPa Online conductive electrode k-1.0 Platinum with temperature compensation 0~20.00ms/cm 0~100℃ 0.6MPa Online conductive electrode k-10.0 Platinum with temperature compensation 0~200.0ms/cm 0~100℃ 0.6MPa Online conductive electrode k-30.0 Platinum with temperature compensation 0~600.0ms/cm 0~100℃ 0.6MPa
According to different installation methods, conductive electrodes have different external structures, usually divided into flow type, pipeline type, submerged type, chuck type, and flange type conductive electrodes. The specific electrode external structure should be selected according to the customer's industrial site conditions; Select the electrode constant based on the estimated conductivity value of the water quality to be tested.Cannot measure low conductivity values with a wide range of constants
1. Before use, the appropriate electrode constant should be selected based on the conductivity value of the tested water sample. Using beyond the measurement range of this electrode can result in significant errors or even render it ineffective.
2. Before use, the constant of the conductive electrode should be entered correctly into the secondary table.
3. After using the electrode for a period of time, it should be cleaned. The method is to soak the electrode in a 3% HCl (dilute hydrochloric acid) solution for two minutes, and then rinse with purified water.
4. If the electrode is installed in a submerged manner, be careful not to let water enter the top of the electrode and the wire. The general method used is to thread the electrode lead out of the protective sleeve, and then connect the thread on the top of the electrode to the thread on the protective sleeve with a tape.