D334 online corrosion-resistant and high-temperature resistant pH electrode

NegotiableUpdate on 09/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Adopting the circular large section Teflon diaphragm imported from Germany, the electrode has stable liquid contact potential and low resistance characteristics, anti clogging, anti pollution, and high temperature resistance. Application field: Industrial wastewater, waste water, and reclaimed water treatment engineering for acid-base cleaning in industrial sites where high heat is generated during water treatment through acid-base neutralization reactions

Product Details

Our company uses advanced foreign technology to produce pH triple composite electrodes, which have superior performance and are particularly suitable for high-temperature applications. The electrode has the following significant characteristics:
1. The electrode is easy to use and does not require additional electrolyte.
2. The measurement range of the electrode is 0-14 pH and the temperature range is 0-120 ℃.
3. The electrode has fast response time, good stability, and strong anti-interference ability.
4. The electrode is not easily contaminated or blocked, and has a long service life.

The electrode is suitable for measuring pure water with a conductivity of ≥ 0.1us/cm.

Measurement range: High temperature strong alkali sensitive glass film imported from Germany is used,

PH range 3-14, temperature range 90-120 ℃, pressure range ≤ 0.6Mpa, zero potential PH=7.00

Dimensions: Electrode dimensions of Ø 12 × 120, 150, 225 or other sizes

1. The electrode should be stored in a dry environment at 10 ℃~30 ℃.
2. When the temperature is below -5 ℃, the electrode may break due to the freezing of the buffer and electrolyte.
3. Due to transportation reasons, when using electrodes, it is necessary to observe whether the sensitive membrane bubble is filled with solution. If there are bubbles in the membrane bubble, gently shake it downwards a few times (like shaking a thermometer) to fill the membrane bubble with solution.
4. If the pH electrode is stored under dry conditions, it must be soaked for 24 hours before use, otherwise it is difficult to calibrate.
5. When the electrode cap is not used, the electrode should be placed in KCL solution, such as 3.0N KCL solution or buffer solution, and not in distilled water.
6. Each electrode needs to be calibrated before it can be used in conjunction with a pH meter. Two point calibration is required for pH electrodes, and standard buffer solutions (pH 6.86, pH 4.00, or pH 9.18) should be used for calibration.
7. The frequency of accurate or checked measurement electrodes depends on different application conditions (such as the degree of dirt in the application, deposition of chemical substances, etc.).


Standard configuration: Comes with a 10 meter electrode cable (customized on site, do not easily cut or extend the cable)


Refer to the installation method of the corresponding product!