Phone
13161155909
-
Address
707, 7th Floor, Building 4, No. 34 Caogezhuang Road, Mentougou District, Beijing
Beijing Runhengao Instrument Equipment Co., Ltd
13161155909
707, 7th Floor, Building 4, No. 34 Caogezhuang Road, Mentougou District, Beijing
Overview:
The RHA-TST3830 dynamic and static strain testing and analysis system is designed specifically for high-speed strain measurement, with a maximum sampling frequency of 100Hz. This system is widely used in various testing sites such as bridge dynamic and static load tests, pseudo dynamic tests, fatigue tests, etc. It can collect various physical quantities such as stress-strain, voltage, displacement, temperature, etc., and is widely used by many universities and research and testing institutions in China.
Application scope:
1. According to the measurement plan, complete the measurement and analysis of dynamic and static strain stress in 1/4 bridge (three wire system, common compensation), half bridge, and full bridge states;
2. Equipped with various bridge sensors, it can measure and analyze various physical quantities such as pressure, force, load, displacement, etc;
3. Equipped with thermocouples, temperature measurement and analysis can be achieved;
4. Paired with TST126, it can achieve modal analysis of large-scale structural experiments.
3、 Software functions
A sampling control and analysis software developed using Vc++in the Chinese Windows 2000/XP/Vista/7 operating system, which has strong real-time performance, as well as good portability, scalability, and upgradability;
2. Enter the elastic modulus and Poisson's ratio of the tested material, and the software will complete the calculation of stress and the principal stress and direction of strain flowers such as two right angles/three 45 ° right angles, 60 ° equilateral triangles/umbrellas, sectors, etc;
3. Complete the unit of the measured physical quantity based on the output sensitivity of the sensor; Normalization of dimensions, directly displaying the measured physical quantity; The computer automatically completes the control of balance and trial sampling, and defines the measurement data of two optional measuring points as the X-axis and Y-axis, drawing curves while sampling, and completing the function of an X-Y recorder (hysteresis curve);
To prevent data loss, prioritize saving data based on the sampling time. The management of data includes functions such as opening files, backing up data, deleting files, and converting data formats (TXT, MAT, EXCEL), ensuring convenient and reliable data processing.

| Quantity points | 16 measurement points per sampling box | ||
| Each testing system can control up to 8 data acquisition boxes | |||
| Each computer can control up to 32 testing systems | |||
| Sampling rate (continuous sampling) | 1. 2, 5, 10, 20, 50, 100 (Hz)/channel | ||
| A/D resolution | 24 digits | ||
| 1/4 bridge resistance range | 120 Ω, 350 Ω programmable switching | ||
| Half bridge and full bridge resistance range | 50 Ω~10000 Ω can be set arbitrarily | ||
| Sensitivity coefficient of strain gauge | 1.0~3.0 automatic correction | ||
| Supply bridge voltage (DC) | Switching between 2V, 5V, and 10V in stages | ||
| Strain range | ± 50000 μ ε, ± 5000 μ ε; Minimum resolution of 0.5 μ ε | ||
| Voltage range | ±5000mV; ±500mV、±50mV; 最小分辨率5μV | ||
| System accuracy | Level 0.5 (not greater than 0.5% ± 3 μ ε) | ||
| zero drift | Not greater than 4 μ ε/4h | ||
| Anti mixing filtering | Cut off frequency 15Hz, stopband attenuation greater than -80dB/oct | ||
| Automatic balancing range | ± 20000 μ ε (± 2% of strain gauge resistance) | ||
| Range of resistance correction for long wires | 0.0 to 100Ω | ||
| contact method | The power supply/controller communicates with the computer via Ethernet The acquisition module and power/controller communicate via CAN bus |
||
| power supply | Power supply/controller power supply | AC power input | 220V±10% 50Hz±2% |
| DC power input | DC18~36V The power supply current is related to the number of connected acquisition modules |
||
| Power supply for data acquisition module | power supply method | Directly powered by power supply/controller or external DC power supply | |
| power supply range | DC18~36V | ||
| Usage environment | temperature | Storage conditions: -40 ℃ to 60 ℃; Extreme conditions: -10 ℃ to 50 ℃; Working range: 0 ℃~40 ℃; |
|
| humidity | Working range: 40 ℃ (20-90)% RH; Storage conditions: 50 ℃ 90% RH24h; |
||
| vibration (Non working state) |
Frequency cycle range: 5-55-5Hz; Drive amplitude (peak): 0.19mm; Sweep rate: less than or equal to 1 octave band/min; Holding time at the resonance point: 10 minutes; Vibration direction: x, y, z. |
||
| Overall dimensions | 220mm×153mm×47mm | ||
| Qianyu Wangpu | https://34674.qianyuwang.com/ |