Dynamic and Static Strain Testing and Analysis System

NegotiableUpdate on 03/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Overview: RHA-TST3830 Dynamic and Static Strain Testing and Analysis System, designed specifically for high-speed strain measurement, with a maximum sampling frequency of 100Hz
Product Details

Overview:
The RHA-TST3830 dynamic and static strain testing and analysis system is designed specifically for high-speed strain measurement, with a maximum sampling frequency of 100Hz. This system is widely used in various testing sites such as bridge dynamic and static load tests, pseudo dynamic tests, fatigue tests, etc. It can collect various physical quantities such as stress-strain, voltage, displacement, temperature, etc., and is widely used by many universities and research and testing institutions in China.
Application scope:
1. According to the measurement plan, complete the measurement and analysis of dynamic and static strain stress in 1/4 bridge (three wire system, common compensation), half bridge, and full bridge states;
2. Equipped with various bridge sensors, it can measure and analyze various physical quantities such as pressure, force, load, displacement, etc;
3. Equipped with thermocouples, temperature measurement and analysis can be achieved;
4. Paired with TST126, it can achieve modal analysis of large-scale structural experiments.
3、 Software functions
A sampling control and analysis software developed using Vc++in the Chinese Windows 2000/XP/Vista/7 operating system, which has strong real-time performance, as well as good portability, scalability, and upgradability;
2. Enter the elastic modulus and Poisson's ratio of the tested material, and the software will complete the calculation of stress and the principal stress and direction of strain flowers such as two right angles/three 45 ° right angles, 60 ° equilateral triangles/umbrellas, sectors, etc;
3. Complete the unit of the measured physical quantity based on the output sensitivity of the sensor; Normalization of dimensions, directly displaying the measured physical quantity; The computer automatically completes the control of balance and trial sampling, and defines the measurement data of two optional measuring points as the X-axis and Y-axis, drawing curves while sampling, and completing the function of an X-Y recorder (hysteresis curve);
To prevent data loss, prioritize saving data based on the sampling time. The management of data includes functions such as opening files, backing up data, deleting files, and converting data formats (TXT, MAT, EXCEL), ensuring convenient and reliable data processing.


Quantity points 16 measurement points per sampling box
Each testing system can control up to 8 data acquisition boxes
Each computer can control up to 32 testing systems
Sampling rate (continuous sampling) 1. 2, 5, 10, 20, 50, 100 (Hz)/channel
A/D resolution 24 digits
1/4 bridge resistance range 120 Ω, 350 Ω programmable switching
Half bridge and full bridge resistance range 50 Ω~10000 Ω can be set arbitrarily
Sensitivity coefficient of strain gauge 1.0~3.0 automatic correction
Supply bridge voltage (DC) Switching between 2V, 5V, and 10V in stages
Strain range ± 50000 μ ε, ± 5000 μ ε; Minimum resolution of 0.5 μ ε
Voltage range ±5000mV; ±500mV、±50mV; 最小分辨率5μV
System accuracy Level 0.5 (not greater than 0.5% ± 3 μ ε)
zero drift Not greater than 4 μ ε/4h
Anti mixing filtering Cut off frequency 15Hz, stopband attenuation greater than -80dB/oct
Automatic balancing range ± 20000 μ ε (± 2% of strain gauge resistance)
Range of resistance correction for long wires 0.0 to 100Ω
contact method The power supply/controller communicates with the computer via Ethernet
The acquisition module and power/controller communicate via CAN bus
power supply Power supply/controller power supply AC power input 220V±10% 50Hz±2%
DC power input DC18~36V
The power supply current is related to the number of connected acquisition modules
Power supply for data acquisition module power supply method Directly powered by power supply/controller or external DC power supply
power supply range DC18~36V
Usage environment temperature Storage conditions: -40 ℃ to 60 ℃;
Extreme conditions: -10 ℃ to 50 ℃;
Working range: 0 ℃~40 ℃;
humidity Working range: 40 ℃ (20-90)% RH;
Storage conditions: 50 ℃ 90% RH24h;
vibration
(Non working state)
Frequency cycle range: 5-55-5Hz;
Drive amplitude (peak): 0.19mm;
Sweep rate: less than or equal to 1 octave band/min;
Holding time at the resonance point: 10 minutes;
Vibration direction: x, y, z.
Overall dimensions 220mm×153mm×47mm