Eaton Rack/Tower Conversion | Eaton DX RT UPS 1-20Kva

NegotiableUpdate on 10/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Eaton DX RT UPS is a new generation of intelligent UPS power supply designed by Eaton Corporation to effectively meet the high-quality power requirements of modern IT equipment and network communication applications. It can be well matched with advanced modern IT equipment. Eaton DX RT Excellent Performance: Eaton UPS Power DX RT adopts an online dual conversion structure to provide continuous clean power, protecting critical electrical equipment from power outages, voltage instability, frequency drift, harmonic interference, and other impacts from the grid

Product Details

Eaton DX RT UPS is a new generation of intelligent UPS power supply designed by Eaton Corporation to effectively meet the high-quality power requirements of modern IT equipment and network communication applications. It can be well matched with advanced modern IT equipment.

Eaton DX RT Excellent Performance:

Eaton's UPS DX RT adopts an online dual conversion structure to provide continuous clean power, protecting critical electrical equipment from power outages, voltage instability, frequency drift, harmonic interference, and other impacts from the grid

Up to 0.9 output, high efficiency, high input power factor, fully matched with modern IT load equipment, energy-saving and environmentally friendly, and bringing additional benefits to customers

Built in parallel function (6KVA or above) provides higher levels of power protection for the most critical systems, ensuring system reliability greater than 99.99%

Humanized design, easy to navigate Chinese culture LCD graphic display and LED status display, easy to manage and operate

Flexible installation, RT type design, can be installed as a regular tower or rack type in standard IT cabinets; The compact internal structure design reduces equipment volume and saves valuable installation space

• Rich output power distribution and communication monitoring accessories to meet the different installation and management needs of IT administrators

Eaton's globally unified monitoring solution, integrated with Eaton's full range of UPS on the same monitoring platform, enables unified management and monitoring within the network

The application of multiple Eaton patents and leading technologies has improved the reliability and availability of the system


1. Dual conversion design provides reliable power protection

The Eaton DX RT series UPS power supply is a dual conversion pure online design, which allows Eaton's DX RT UPS to provide continuous and stable power supply to the critical IT load equipment it protects even in the event of the most serious power problems in the mains.

The Eaton UPS DX RT series has an extremely wide input voltage range. When there are large fluctuations in the mains voltage, there is no need to rely on the battery to eliminate these power fluctuations, avoiding frequent discharge of the battery due to fluctuations in the mains voltage, saving battery power, and adapting to very unstable power usage environments.

The zero interruption conversion feature of Eaton's UPS DX RT series ensures good power protection for massive data processing systems and high-speed network communication equipment in the event of unstable or completely interrupted mains power (i.e. power outage).

2. High performance, matching the protection requirements of the new generation of IT equipment

Eaton UPS Power DX

The output power factor of the RT series is as high as 0.9, providing stronger load capacity,

It is compatible with modern computer devices that commonly use input power factor correction circuits, and has low input harmonics, making it environmentally friendly. Advanced DSP

Fully digital control technology, more precise control, smaller overall size, compatible with tower and rack mounted (standard 19 inch cabinet) installation, suitable for a wide range of computer room application environments, saving investment costs.

The Eaton UPS DX RT series long delay UPS can provide ultra long backup delay time from ten minutes to eight hours by connecting external standard battery modules or third-party battery boxes.

3. Energy saving, green and environmentally friendly power protection

Eaton UPS Power DX

The high input and output power factor, high efficiency, and low input harmonics design of the RT series improve the conversion efficiency of the power supply, enhance the utilization of power grid resources, effectively reduce harmonic feedback pollution to the power grid, and greatly reduce its own heat generation and reduce the impact of system noise on the application environment. The green and environmentally friendly design concept that conforms to the new power supply also reduces operating costs for users.

4. High availability, humanized design

The powerful processor inside Eaton DX RT provides comprehensive real-time monitoring of voltage, temperature, and the operation of key internal components, battery operation, charging status, and remaining operating time. If UPS detects potential issues, it will issue an alarm through the Chinese LCD graphic display panel and UPS status indicator light to remind users to take necessary corrective measures

The wide input voltage range of 110VAC-300VAC, stable and reliable standard sine wave AC power output, and good overload capacity make the Eaton DX RT applicable to any power supply environment

User replaceable battery pack: allows battery pack replacement during normal operation of UPS 3

Parallel function: Implement 2+1 redundant parallel or capacity expansion parallel through parallel components (for models above 6KVA)

5. Intelligent management and monitoring

Eaton DX RT supports the Eaton Software Suit package, which includes SNMP compatible power management software, LanSafe, Netwatch, and multi language IPM/IP centralized monitoring software based on B/C architecture.

Using an intuitive graphical interface, the entire UPS system can be displayed and controlled. Users can automatically shut down multiple servers through TCP/IP networks, and monitor all networked port UPS systems with a single node to obtain real-time information on the operation of port UPS,

And remote maintenance and management of UPS can be carried out if allowed (with connectivity options: for Eaton DX RT in various environments)

UPS monitoring provides connection interfaces and communication protocols. The Eaton DX RT standard device is equipped with a monitoring device. RS-232 serial communication interface and expansion communication slot. By expanding the slot, communication card options can also be added: Integrate UPS into SNMP based network management system using Web/SNMP card, and manage UPS through standard web browser. Modbus/Jbus card for building intelligent monitoring An eight AS/400 relay interface card that sends relay contact alarm notification signals to remote security systems Eaton UPS Power DX RT Series Product Technical Parameters model
DX RT 1KV
DX RT 2KVA
DX RT 3KVA
DX RT 6KVA
DX RT 10KVA
DX RT
10KVA
(3:1)
DX RT 15KVA (3:1) DX RT 20KVA (3:1) power 1000VA 2000VA
3000VA 6000VA 10KVA 10KVA 15KVA
20KVA 0.98 input voltage range
110VAC ~300VAC 121VAC-275VAC
208-474VAC power factor >0.99
>0.99 Harmonic distortion (THDI)
<5% 0.9
output voltage
220VAC±2%
frequency
50Hz ± 0.2 Hz (battery mode)
power factor
overload capacity
100%~108%: Alarm and continuous operation;
When<150%:>30 seconds;
>At 150%,>300 milliseconds
110%~125%: 60 seconds; 125% to 150%: 30 seconds; >150%: 0.5 seconds
105%~125%: 60 seconds; 125% to 135%: 30 seconds; >135%: 0.2 seconds battery type Valve controlled maintenance free lead-acid type battery voltage
36VDC 72VDC 96VDC 240VDC
240VDC 384VDC Full load backup time (standard machine) >4 min. >3min - complete machine
efficiency >0.89 >0.90 >0.90 19 20 32
>0.92 >0.92/0.97(ECO Mode) Weight (standard machine/long machine) kg 15/8.2
10.5/9.6 10.9/10 Host height 2U 19 21 32 38
3U 3U weight 15.1/8.1
9.1/10.1 9.6/10.7 size 450*438*88
443*676*130 442*856*130
Parallel machine No
Yes Yes

















Static bypass
built-in

interface Graphic LCD+LED indicator light communication Standard RS 232; Intelligent expansion communication slot (3) Battery configuration Battery pack configuration: model battery voltage Standard 1EBM +1EBM
+2EBM +3EBM 4 21 36 60 80 100 122 150
+4EBM +5EBM 4 10 18 28 39 50 62 75
+6EBM +7EBM 4 9 16 26 28 42 54 65
1K 36VDC 5 11 20 30 41 54 66 79
2K 72VDC 3 8 15 22 30 39 50 64
3K 96VDC 6K 7 20 29 42 54 68 83
240VDC 10K 240VDC 4 11 20 29 40 52 61
10K(3:1) 384VDC - 3 7 12 20 30 39 51


15K(3:1)

384VDC - 20K(3:1) 384VDC
- External battery configuration:
model battery voltage External battery 3 41
Power supply time (min) 58
battery capacity 100
Number of batteries 171
1K 36VDC 24Ah 6 50
38Ah 80
65Ah 136
100Ah 190
2K 72VDC 24Ah 8 40
38Ah 50
65Ah 100
100Ah 140
3K 96VDC 24Ah 20 41
38Ah 65
65Ah 112
100Ah 171
6K 240VDC 24Ah 20 25
38Ah 40
65Ah 67
100Ah 102
10K 240VDC 24Ah 32 39
38Ah 63
65Ah 106
100Ah 163
10K(3:1) 384VDC 24Ah 32 26
38Ah 42
65Ah 71
100Ah 108
15K(3:1) 384VDC 24Ah 32 20
38Ah 32
65Ah 54
100Ah 82