Eaton DX RT UPS is a new generation of intelligent UPS power supply designed by Eaton Corporation to effectively meet the high-quality power requirements of modern IT equipment and network communication applications. It can be well matched with advanced modern IT equipment.
Eaton DX RT Excellent Performance:
Eaton's UPS DX RT adopts an online dual conversion structure to provide continuous clean power, protecting critical electrical equipment from power outages, voltage instability, frequency drift, harmonic interference, and other impacts from the grid
Up to 0.9 output, high efficiency, high input power factor, fully matched with modern IT load equipment, energy-saving and environmentally friendly, and bringing additional benefits to customers
Built in parallel function (6KVA or above) provides higher levels of power protection for the most critical systems, ensuring system reliability greater than 99.99%
Humanized design, easy to navigate Chinese culture LCD graphic display and LED status display, easy to manage and operate
Flexible installation, RT type design, can be installed as a regular tower or rack type in standard IT cabinets; The compact internal structure design reduces equipment volume and saves valuable installation space
• Rich output power distribution and communication monitoring accessories to meet the different installation and management needs of IT administrators
Eaton's globally unified monitoring solution, integrated with Eaton's full range of UPS on the same monitoring platform, enables unified management and monitoring within the network
The application of multiple Eaton patents and leading technologies has improved the reliability and availability of the system
1. Dual conversion design provides reliable power protection
The Eaton DX RT series UPS power supply is a dual conversion pure online design, which allows Eaton's DX RT UPS to provide continuous and stable power supply to the critical IT load equipment it protects even in the event of the most serious power problems in the mains.
The Eaton UPS DX RT series has an extremely wide input voltage range. When there are large fluctuations in the mains voltage, there is no need to rely on the battery to eliminate these power fluctuations, avoiding frequent discharge of the battery due to fluctuations in the mains voltage, saving battery power, and adapting to very unstable power usage environments.
The zero interruption conversion feature of Eaton's UPS DX RT series ensures good power protection for massive data processing systems and high-speed network communication equipment in the event of unstable or completely interrupted mains power (i.e. power outage).
2. High performance, matching the protection requirements of the new generation of IT equipment
Eaton UPS Power DX
The output power factor of the RT series is as high as 0.9, providing stronger load capacity,
It is compatible with modern computer devices that commonly use input power factor correction circuits, and has low input harmonics, making it environmentally friendly. Advanced DSP
Fully digital control technology, more precise control, smaller overall size, compatible with tower and rack mounted (standard 19 inch cabinet) installation, suitable for a wide range of computer room application environments, saving investment costs.
The Eaton UPS DX RT series long delay UPS can provide ultra long backup delay time from ten minutes to eight hours by connecting external standard battery modules or third-party battery boxes.
3. Energy saving, green and environmentally friendly power protection
Eaton UPS Power DX
The high input and output power factor, high efficiency, and low input harmonics design of the RT series improve the conversion efficiency of the power supply, enhance the utilization of power grid resources, effectively reduce harmonic feedback pollution to the power grid, and greatly reduce its own heat generation and reduce the impact of system noise on the application environment. The green and environmentally friendly design concept that conforms to the new power supply also reduces operating costs for users.
4. High availability, humanized design
The powerful processor inside Eaton DX RT provides comprehensive real-time monitoring of voltage, temperature, and the operation of key internal components, battery operation, charging status, and remaining operating time. If UPS detects potential issues, it will issue an alarm through the Chinese LCD graphic display panel and UPS status indicator light to remind users to take necessary corrective measures
The wide input voltage range of 110VAC-300VAC, stable and reliable standard sine wave AC power output, and good overload capacity make the Eaton DX RT applicable to any power supply environment
User replaceable battery pack: allows battery pack replacement during normal operation of UPS 3
Parallel function: Implement 2+1 redundant parallel or capacity expansion parallel through parallel components (for models above 6KVA)
5. Intelligent management and monitoring
Eaton DX RT supports the Eaton Software Suit package, which includes SNMP compatible power management software, LanSafe, Netwatch, and multi language IPM/IP centralized monitoring software based on B/C architecture.
Using an intuitive graphical interface, the entire UPS system can be displayed and controlled. Users can automatically shut down multiple servers through TCP/IP networks, and monitor all networked port UPS systems with a single node to obtain real-time information on the operation of port UPS,
And remote maintenance and management of UPS can be carried out if allowed (with connectivity options: for Eaton DX RT in various environments)
| UPS monitoring provides connection interfaces and communication protocols. | The Eaton DX RT standard device is equipped with a monitoring device. RS-232 serial communication interface and expansion communication slot. By expanding the slot, communication card options can also be added: | Integrate UPS into SNMP based network management system using Web/SNMP card, and manage UPS through standard web browser. | Modbus/Jbus card for building intelligent monitoring | An eight AS/400 relay interface card that sends relay contact alarm notification signals to remote security systems | Eaton UPS Power DX RT Series Product Technical Parameters | model DX RT 1KV DX RT 2KVA |
DX RT 3KVA DX RT 6KVA DX RT 10KVA |
DX RT 10KVA (3:1) |
|||||||
| DX RT | 15KVA | (3:1) | DX RT | 20KVA | (3:1) | power | 1000VA | 2000VA | |||||||
| 3000VA | 6000VA | 10KVA | 10KVA | 15KVA | |||||||||||
| 20KVA | 0.98 | input | voltage range | ||||||||||||
| 110VAC ~300VAC | 121VAC-275VAC | ||||||||||||||
| 208-474VAC | power factor | >0.99 | |||||||||||||
| >0.99 | Harmonic distortion (THDI) | ||||||||||||||
| <5% | 0.9 | ||||||||||||||
| output | voltage 220VAC±2% frequency |
50Hz ± 0.2 Hz (battery mode) power factor overload capacity |
100%~108%: Alarm and continuous operation; When<150%:>30 seconds; >At 150%,>300 milliseconds |
||||||||||||
| 110%~125%: 60 seconds; | 125% to 150%: 30 seconds; | >150%: 0.5 seconds | |||||||||||||
| 105%~125%: 60 seconds; | 125% to 135%: 30 seconds; | >135%: 0.2 seconds | battery | type | Valve controlled maintenance free lead-acid type | battery voltage | |||||||||
| 36VDC | 72VDC | 96VDC | 240VDC | ||||||||||||
| 240VDC | 384VDC | Full load backup time (standard machine) | >4 min. | >3min | - | complete machine | |||||||||
| efficiency | >0.89 | >0.90 | >0.90 | 19 | 20 | 32 | |||||||||
| >0.92 | >0.92/0.97(ECO Mode) | Weight (standard machine/long machine) kg | 15/8.2 | ||||||||||||
| 10.5/9.6 | 10.9/10 | Host height | 2U | 19 | 21 | 32 | 38 | ||||||||
| 3U | 3U | weight | 15.1/8.1 | ||||||||||||
| 9.1/10.1 | 9.6/10.7 | size | 450*438*88 | ||||||||||||
| 443*676*130 | 442*856*130 | ||||||||||||||
| Parallel machine | No | ||||||||||||||
| Yes | Yes | ||||||||||||||
Static bypass
built-in
| interface | Graphic LCD+LED indicator light | communication | Standard RS 232; Intelligent expansion communication slot | (3) Battery configuration | Battery pack configuration: | model | battery voltage | Standard 1EBM | +1EBM |
| +2EBM | +3EBM | 4 | 21 | 36 | 60 | 80 | 100 | 122 | 150 |
| +4EBM | +5EBM | 4 | 10 | 18 | 28 | 39 | 50 | 62 | 75 |
| +6EBM | +7EBM | 4 | 9 | 16 | 26 | 28 | 42 | 54 | 65 |
| 1K | 36VDC | 5 | 11 | 20 | 30 | 41 | 54 | 66 | 79 |
| 2K | 72VDC | 3 | 8 | 15 | 22 | 30 | 39 | 50 | 64 |
| 3K | 96VDC | 6K | 7 | 20 | 29 | 42 | 54 | 68 | 83 |
| 240VDC | 10K | 240VDC | 4 | 11 | 20 | 29 | 40 | 52 | 61 |
| 10K(3:1) | 384VDC | - | 3 | 7 | 12 | 20 | 30 | 39 | 51 |
15K(3:1)
| 384VDC | - | 20K(3:1) | 384VDC | |
| - | External battery configuration: | |||
| model | battery voltage | External battery | 3 | 41 |
| Power supply time (min) | 58 | |||
| battery capacity | 100 | |||
| Number of batteries | 171 | |||
| 1K | 36VDC | 24Ah | 6 | 50 |
| 38Ah | 80 | |||
| 65Ah | 136 | |||
| 100Ah | 190 | |||
| 2K | 72VDC | 24Ah | 8 | 40 |
| 38Ah | 50 | |||
| 65Ah | 100 | |||
| 100Ah | 140 | |||
| 3K | 96VDC | 24Ah | 20 | 41 |
| 38Ah | 65 | |||
| 65Ah | 112 | |||
| 100Ah | 171 | |||
| 6K | 240VDC | 24Ah | 20 | 25 |
| 38Ah | 40 | |||
| 65Ah | 67 | |||
| 100Ah | 102 | |||
| 10K | 240VDC | 24Ah | 32 | 39 |
| 38Ah | 63 | |||
| 65Ah | 106 | |||
| 100Ah | 163 | |||
| 10K(3:1) | 384VDC | 24Ah | 32 | 26 |
| 38Ah | 42 | |||
| 65Ah | 71 | |||
| 100Ah | 108 | |||
| 15K(3:1) | 384VDC | 24Ah | 32 | 20 |
| 38Ah | 32 | |||
| 65Ah | 54 | |||
| 100Ah | 82 | |||