Brief description: The LX-5000 explosion-proof industrial process chromatograph inherits the excellent design of Langmuir instruments in industrial chromatographic analysis, adopting both a new industrial design and validated high reliability components. In addition, the built-in automatic detection function reduces the overall cost of ownership for users, making it an industrial chromatograph that can meet the requirements for analysis reliability and accuracy.
Product Details
Details
brand Self operated brand Instrument type on line
Origin category domestic Price range discuss personally
Applications general use application area Medical and health care, environmental protection, chemical industry, petroleum, energy

The LX-5000 explosion-proof industrial process chromatograph has powerful contemporary electronic and software technology and industrial chromatographic analysis performance. The instrument adopts highly integrated industrial grade chips, bus technology, Ethernet technology, microflow gas control technology, and data processing software, optimizing temperature control accuracy and gas flow and pressure control accuracy, improving the reliability and stability of the instrument, and making LX-5000 a truly modern industrial chromatograph in China.

The LX-5000 chromatograph provides hardware and electronic technologies that have been validated in terms of reliability and operability, while taking the application of industrial gas chromatography to a higher level. The reliability of analysis hardware such as valves and detectors has also been verified for many years in LX-3000. In addition to having many common spare parts between the two models, the LX-5000 also uses the same Ethernet network. The new version of the chromatography workstation software can be used for two types of chromatographs on the same network.

The LX-5000 chromatograph has a built-in 10.4-inch industrial color touch screen display, which simplifies the maintenance process. Technicians can view all analysis parameters and measurement results on a simple color screen. From the overview screen of the analyzer's operation to the processing screen of data analysis, users can easily obtain information or know the tasks that need to be completed. All operating parameters of the gas chromatograph, such as opening and closing time and valve time, are displayed on the screen simultaneously. While simplifying the maintenance process of gas chromatography, technicians who have not used LX-5000 can quickly master it without excessive training. Comparing the current spectrum with stored or calibrated spectra can easily confirm the analysis effect.

Technical parameters

LX-5000 Explosion proof Industrial Process Chromatography Instrument

control mode

Built in 10.4-inch industrial color touch screen industrial computer

Detection channel

Single channel, dual channel

detector

PDHID、TCD、FID

column oven

Room temperature: 4 ℃~135 ℃, increment: 1 ℃, accuracy: ± 0.1 ℃

LRV

nL/L、μL/L、%

Drift/repeatability

±1%~±5%

Sample gas flow rate

30~100mL/min

Sample gas pressure

0.05~0.3MPa

Carrier gas type

He(or N2、Ar、H2)

carrier gas flow

30~150mL/min

Carrier gas pressure

0.4 MPa

Instrument air

Pressure: 350-900kPa Flow rate: 150-210L/min

power supply

220VAC,50~60Hz

energy consumption

1.5kW~2kW

weight

100kg

size

Wall mounted cabinet

600mm(W)×950mm(H)×400mm(D)

flow control

EPC、 Flow meter and electronic monitoring are optional

Flow path control

Less than or equal to 60 channels (including calibrated flow channels)

Analysis cycle

Less than or equal to 21600.0 seconds (6 hours)

work environment

-30-60 ℃, below 95% RH (no condensation)

workstation

The digital communication technology used directly displays the analysis results and uploads them to the upper computer (DCS or LX-5000 integrated data software, etc.). The instrument automatically alarms for faults and uploads them to the upper computer. After the FID extinguishes the fire, it automatically ignites, and if it fails to ignite five times, it automatically cuts off the hydrogen gas. The instrument is equipped with a built-in hydrogen alarm device, which monitors the hydrogen content in real time. If the content exceeds the standard, the power will be automatically cut off, and if the pressure drops, the power will be automatically cut off. Multiple measures are taken to ensure the safe operation of the instrument. Debugging parameters require authorization codes and one click calibration to ensure the safety and reliability of analysis data. Make monitoring data more effective and secure

Explosion proof sign

Ex d e px IIC T4 Gb

signal output

4-20mA (12 channels) RS232/RS485、 Ethernet