Mechanical characteristics of FCF series four column precision gas-liquid booster press: 1. It is driven by a hydraulic booster cylinder and can work under pressure at any position of the stroke

Product Details

FCF series four column precision gas-liquid booster press

Mechanical characteristics:

1. Driven by a hydraulic booster cylinder, it can work under pressure at any position of the stroke.
2. The body adopts a four column gantry frame structure, welded with steel plates, which has good rigidity and high strength.
3. After eliminating internal stress in the welded body, the reference surface is machined in one go on large equipment.
4. The upper mold fixing plate adopts a double guide column structure, which not only prevents rotation, but also has excellent guiding accuracy.
5. The workbench and upper mold fixing plate adopt double T-shaped slots to install and fix the mold, which is convenient, stable and reliable.
6. The working process is vibration free, impact free, and noise free, greatly improving the quality of workpiece processing and mold life.
7. The output pressure is directly proportional to the gas source pressure, making it convenient and fast to adjust the output pressure and operating speed.
8. Only 10% -20% of the energy consumption of ordinary mechanical presses or hydraulic presses, greatly saving costs.
9. The electronic control system can set the working cycle and holding time, and record the number of working times.

The FCF series precision gas-liquid booster press adopts a four column structure for the body. In order to facilitate the up and down of the workpiece, the four columns of the body are close to the middle. This structure ensures uniform and consistent force on the machine body during operation, ensuring that the centerline of the cylinder is perpendicular to the worktable and facilitating the operator's up and down picking of the workpiece.

Product Usage:Suitable for use in various industries such as hardware, electronics, electrical appliances, automobiles, machinery, watches, instruments, etc. in processes such as assembly, cutting, forming, flanging, pressing, riveting, punching, calibration, and embossing.
It is an ideal equipment to replace hydraulic presses, large bore pneumatic presses, and mechanical punching machines.

Order code:

For example, ordering a four column gas-liquid booster press with a nominal pressure of 80KN (0.7MPa), a total stroke of 100, a force stroke of 10, a B-type upper mold installation method, using two hand button operation, and a precision gas-liquid booster press with safety light curtain protection.
Order code: FCF-08-B-100-10-MG

Optional components:

气液增力压力机 气液增力压力机 气液增力压力机 气液增力压力机
Cylinder magnetic ring ordering code-S Order code - J with pressure measuring interface Adjustable order code for force travel - A Induction switch (travel switch) ordering code-K
气液增力压力机 气液增力压力机 气液增力压力机 气液增力压力机
Installation method of upper mold Type A Order code-A Installation method of upper mold B-type ordering code-B Organic glass cover order code-H Seismic pressure gauge ordering code-m
气液增力压力机 气液增力压力机 气液增力压力机 气液增力压力机
Pressure transmitter ordering code-P Order code for safety light curtain - G Operation method (hand press/foot press) Order code-M/F Peak meter ordering code-V
气液增力压力机 气液增力压力机 气液增力压力机 气液增力压力机
Machine worktable (table) ordering code-Z Displacement Sensor Ordering Code-W Order code for waveform comparison monitoring system - X Load sensor ordering code-Y

Performance parameters:

FCF series precision gas-liquid booster press output force, stroke and main parameters

Output force/0.7MPa U V B*T D Main performance parameters
Order model: Working Force Fast forward force Return force Total travel Power stroke table size Closing height work cycle Downward speed hold time operating mode supply voltage Gas consumption External dimensions net weight
[KN] [KN] [KN] [mm] [mm] [mm] [mm] [S] [CM/S] [S] [M/F] [V] [L/time] [CM] [KG]
FCF-02-A-U-V-M/F 20 1.6 1.1 50~200 5~45 310*240 250 1.0 10~60 Any setting Hands/pedals AC220 1.0 69*34*95 100
FCF-02-B-U-V-M/F 270 110
FCF-03-A-U-V-M/F 30 1.6 1.1 50~200 5~45 350*270 280 1.0 10~60 Any setting Hands/pedals AC220 1.4 73*37*97 123
FCF-03-B-U-V-M/F 300 135
FCF-05-A-U-V-M/F 50 1.6 1.1 50~200 5~45 390*300 310 1.1 10~60 Any setting Hands/pedals AC220 2.0 77*40*100 152
FCF-05-B-U-V-M/F 330 170
FCF-08-A-U-V-M/F 80 3.5 2.3 75~200 5~40 420*320 325 1.4 8~48 Any setting Hands/pedals AC220 3.6 82*42*110 200
FCF-08-B-U-V-M/F 350 220
FCF-10-A-U-V-M/F 100 5.4 4.0 75~200 5~30 440*340 340 1.7 5~38 Any setting Hands/pedals AC220 4.8 85*44*120 225
FCF-10-B-U-V-M/F 370 250
FCF-16-A-U-V-M/F 160 5.4 4.0 75~200 5~30 460*360 360 2.4 5~38 Any setting Hands/pedals AC220 7.1 90*46*130 260
FCF-16-B-U-V-M/F 370 290
FCF-25-A-U-V-M/F 250 8.5 6.6 75~200 5~35 480*380 370 3.2 3~30 Any setting Hands/pedals AC220 11.0 93*48*140 325
FCF-25-B-U-V-M/F 380 360

Note: A and B are the installation methods for the upper mold, U is the total stroke (optional 50-75-100-150-200), and V is the force stroke (optional 5-10-15-20-25-30).

Structural dimensions:

Dimensions of the worktable and base structure of the FCF series precision gas-liquid booster press

B T H E α Ts A S M N F G J L P Q
Order model: Dimensions related to the workbench Dimensions related to the base structure
[mm] [mm] [mm] [mm] [°] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
FCF-02-A-U-V-M/F 310 240 120 60 60 12 420 10 200 200 12 30 110 344 300 100
FCF-02-B-U-V-M/F
FCF-03-A-U-V-M/F 350 270 120 70 60 12 460 10 200 230 12 30 130 384 400 100
FCF-03-B-U-V-M/F
FCF-05-A-U-V-M/F 390 300 120 80 60 12 500 10 200 260 12 30 150 424 400 100
FCF-05-B-U-V-M/F
FCF-08-A-U-V-M/F 420 320 120 80 60 12 560 10 200 280 12 40 158 464 400 100
FCF-08-B-U-V-M/F
FCF-10-A-U-V-M/F 440 340 120 80 60 12 580 10 240 280 12 40 160 484 400 100
FCF-10-B-U-V-M/F
FCF-16-A-U-V-M/F 460 360 120 90 60 12 620 10 240 300 12 50 170 514 400 100
FCF-16-B-U-V-M/F
FCF-25-A-U-V-M/F 480 380 120 100 60 12 660 10 240 320 12 60 180 544 400 100
FCF-25-B-U-V-M/F

Note: Other dimensions of T-shaped groove shall be in accordance with GB/T158-1996

type a
type B

FCF series precision gas-liquid booster press - upper mold installation method, A-type, B-type structural dimensions

P1 Q1 B1 T1 H1 M1 N1 G1 F1 R1 E1 K1 W1 S1 B2 T2 H2 E2 α2
Order model: Installation method of A-type small platform screw holes Installation method of A-type mold handle hole B-type upper template size
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [°]
FCF-02-A-U-V-M/F 260 100 100 80 50 80 60 12 9 41.5 25 M10 18 12
FCF-02-B-U-V-M/F 310 220 30 60 60
FCF-03-A-U-V-M/F 260 100 100 80 50 80 60 12 9 41.5 25 M10 18 12
FCF-03-B-U-V-M/F 350 250 30 70 60
FCF-05-A-U-V-M/F 260 100 100 80 50 80 60 12 9 41.5 25 M10 18 12
FCF-05-B-U-V-M/F 390 280 30 80 60
FCF-08-A-U-V-M/F 300 110 120 100 55 100 80 13 11 54 28 M12 20 15
FCF-08-B-U-V-M/F 420 300 30 80 60
FCF-10-A-U-V-M/F 340 120 140 120 60 116 96 14 13 63 32 M16 26 20
FCF-10-B-U-V-M/F 440 320 30 80 60
FCF-16-A-U-V-M/F 340 120 140 120 60 116 96 14 13 63 32 M16 26 20
FCF-16-B-U-V-M/F 460 340 30 90 60
FCF-25-A-U-V-M/F 380 130 164 128 70 134 98 15 17 68 40 M20 32 22
FCF-25-B-U-V-M/F 480 360 30 100 60

Note: Other dimensions of T-shaped groove shall be in accordance with GB/T158-1996