1. Name: Computer Cable① Flame retardant polyvinyl chloride insulation and sheath: fixed installation -40 ℃; Non fixed installation -15 ℃; ② Fluoroplastic insulation and sheath: fixed installation -60 ℃, non fixed installation -20 ℃.
2Flame retardant shielded intrinsic safety control cable, computer cable型号: DJYPV、DJYVP、DJYPVP、DJVVP、JVV、JVVP、DJYPRV
3. This product is suitable for data transmission and anti-interference requirements of electronic computer systems (DCS) with rated voltage of 450/750V and below, as well as weak signal connection transmission of other self-control systems.
4Flame retardant shielded intrinsic safety control cable, computer cableProduct model and name
DJYPV: Polyethylene insulated copper wire braided shielded polyvinyl chloride sheathed flame-retardant electronic computer cable
DJYVP: Polyethylene insulated copper wire braided total shielding PVC sheathed flame-retardant electronic computer cable
DJYPVP: Polyethylene insulated copper wire braided shielded and total shielded PVC sheathed flame-retardant electronic computer cable
DJYPVR: Polyethylene insulated copper wire braided shielded polyvinyl chloride sheathed flame-retardant soft structure electronic computer cable.
DJYVPR: Polyethylene insulated copper wire braided total shielding PVC sheathed flame-retardant soft structure electronic computer cable
DJYPVPR: Polyethylene insulated copper wire braided shielded and total shielded PVC sheathed flame-retardant soft structure electronic computer cable
DJYP2V: Polyethylene insulated copper tape shielded polyvinyl chloride sheathed flame-retardant electronic computer cable
DJYVP2: Polyethylene insulated copper tape total shielding PVC sheathed flame-retardant electronic computer cable
DJYP2VP2: Polyethylene insulated copper tape shielded and total shielded PVC sheathed flame-retardant electronic computer cable
DJYP3V: Polyethylene insulated aluminum-plastic composite tape shielded polyvinyl chloride sheathed flame-retardant electronic computer cable.
DJYVP3: Polyethylene insulated aluminum-plastic composite tape, total shielding, polyvinyl chloride sheath, flame-retardant electronic computer cable
DJYP3VP3: Polyethylene insulated aluminum-plastic composite tape with partial shielding and total shielding, PVC sheathed flame-retardant electronic computer cable
ZR-DJYVP, ZR-DJYVP22: Flame retardant computer cable
Type of intrinsically safe explosion-proof computer cable
Polyethylene insulated PVC sheathed intrinsically safe circuit computer shielded cable (including intrinsically safe DCS cable)
IA-DJYPVP
Polyethylene insulated copper wire braided split screen total screen PVC sheathed intrinsically safe computer shielded cable
IA-DJYP2VP2
Polyethylene insulated copper plastic composite tape wrapped, divided screen copper tape, total screen PVC sheathed, intrinsically safe computer shielded cable
IA-DJYP3VP3
Polyethylene insulated aluminum-plastic composite tape wrapped split screen total screen PVC sheathed computer shielded cable.
Add ZR before the model number for flame-retardant computer cables, add 22 after the armored cable model number, and tin plated copper wire can be used for shielding. The basic model number is slightly larger
Cross linked polyethylene insulated polyvinyl chloride sheathed shielded cables for computers (including DCS cables)
IA-DJYJPVP
Cross linked polyethylene insulated copper wire braided split screen total screen polyvinyl chloride sheathed intrinsically safe computer shielded cable
IA-DJYJP2VP2
Cross linked polyethylene insulated copper tape wrapped split screen total screen polyvinyl chloride sheathed intrinsically safe computer shielded cable
IA-DJYJP3VP3
Cross linked polyethylene insulated aluminum-plastic composite tape wrapped split screen total screen PVC sheathed intrinsically safe computer shielded cable.
Add ZR before the model number for flame-retardant computer cables, add 22 after the armored cable model number, and tin plated copper wire can be used for shielding. The basic model number is slightly larger
Control cable model, name, and scope of use:
KVV PVC insulated and PVC sheathed control cable
KVVP PVC insulated, PVC sheathed copper wire braided shielded control cable
KVVR PVC insulated and PVC sheathed soft control cables are laid in indoor environments where flexibility is required for movement.
KVVRP PVC insulated, PVC sheathed copper wire braided shielding soft control cable has the same anti-interference ability as above.
KVVP2 PVC insulated, PVC sheathed copper tape wrapped shielded control cable as above.
KVV22 PVC insulated, PVC sheathed steel tape armored control wire
KVV32 PVC insulated, fine steel wire armored PVC sheathed control cable
Brief description: Shielded cables for electronic computers are insulated with high-voltage polyethylene with a low dielectric constant. Adopting structural forms such as twisted pair, screen pair, and total screen (or three wire combination, group shielding, group screen total screen), it has the characteristics of low dielectric loss, strong signal transmission ability, and good anti-interference performance. It can reliably transmit weak analog signals and can be widely used in computer systems or automation devices for detection and control in power generation, metallurgy, petroleum, chemical, textile and other departments, as well as general industrial computers.
flame retardantMeaning: Under specified test conditions, the specimen is burned, and after removing the ignition source, the flame spreads only within a limited range on the specimen and extinguishes on its own, which means it has the ability to prevent or delay the occurrence or spread of flames.
Fire resistant control cable shielded cable
NH-KYJV copper core cross-linked polyvinyl chloride insulated flame-retardant polyvinyl chloride sheathed fire-resistant control cable
NH-KYJVR copper core fluoroplastic insulated flame-retardant and polyvinyl chloride sheathed fire-resistant flexible control cable
NH-KYJVP copper core fluoroplastic insulated flame-retardant and polyvinyl chloride sheathed braided shielding fire-resistant control cable
NH-KYJVRP copper core fluoroplastic insulated flame-retardant and polyvinyl chloride sheathed braided shielding fire-resistant soft control cable
NH-KYJVP2 copper core fluoroplastic insulated flame-retardant and polyvinyl chloride sheathed copper tape wrapped fire-resistant control cable
NH-KYJVRP2 copper core fluoroplastic insulated flame-retardant and polyvinyl chloride sheathed copper tape wrapped fire-resistant soft control cable
NH-KYJV22 copper core fluoroplastic insulated flame-retardant and PVC sheathed steel tape armored fire-resistant control cable
The combustion of wires, cables, and cables is caused by the generation of flammable gases through external heating. To achieve flame retardancy, it is necessary to suppress the three elements that cause combustion, namely flammable gases, heat, and oxygen. Therefore,Flame retardant wires and cablesThe commonly used method is to add halides and metal oxides containing halogens to the sheath material. From the perspective of flame retardancy, this is the * method. However, due to the presence of halides in these materials, a large amount of smoke and hydrogen halide gas are released during combustion, resulting in low visibility during a fire and greatly hindering the safe evacuation and firefighting of personnel. People are more likely to suffocate and die from toxic gases.
In addition, once hydrogen halide gas reacts with water in the air, it generates“Hydrogen halide acid”Severe corrosion of instruments, equipment, and buildings“Secondary disasters”.
At present, with the continuous improvement of technology, the problem of flame retardancy has further developed from halogen flame retardancy in the past to low halogen and halogen-free flame retardancy.