Fuji FLR ultrasonic flowmeter from Japan
Fuji, Japan
Product Introduction of Fuji FLR Ultrasonic Flow Meter in Japan:
Product Model: FLR
Product brand: Fuji, Japan
Product Category: Flow Meter
Product note: Ultrasonic flowmeter
Product Introduction of Fuji FLR Ultrasonic Flow Meter in Japan:
Fuji FLR ultrasonic flowmeter has superior bubble resistance and is suitable for small converters used in mechanical devices. It can measure the liquid flow rate from the pipe diameter of φ 25 to φ 1200mm.


Features of Fuji FLR Ultrasonic Flow Meter from Japan:
The standard accuracy is 1.5% of rate (optional 1% of rate)
Fast response in just 0.2 seconds
No need to open the converter casing, operation settings can be made from the front
Comes with RS-485 communication function (optional)
PC loader software is standard equipment




Application of Fuji FLR Ultrasonic Flow Meter in Japan:


Technical parameters of Fuji FLR ultrasonic flowmeter in Japan:
| model | Transformer FSV detector FSS |
| Applicable pipeline diameter | Inner diameter 25-225mm (detector: FSSA) |
| Inner diameter 50-1200mm (detector: FSSC) | |
| Piping material | Plastic (PVC, PVDF, PP, etc.), metal |
| measuring range | 0~±0.3 ±10m/s |
| accuracy | ± 1.5% of rate or ± 1.0% of rate (when the flow rate is above 2m/s) |
| response speed | 0.2s (in high-speed response mode) |
| Fluid temperature | -20~+100 ℃ (detector FSSA) |
| -40~+120 ℃ (detector FSSC) | |
| ambient temperature | -20~+50 ℃ (converter), -20~+60 80 ℃ (depending on the detector) |
| analog output | DC4~20mA、 1 point (with a load resistance of 600 Ω) |
| Contact output | Open collector output: 2-point, cumulative, alarm, etc |
| 1P/day~100P/s (open collector) | |
| Serial Transmission | RS-485/MODBUS (option) |
| display | LCD (2-line, 16 bit) with backlight |
| keyboard | 4 keys (Esc, Up, Shift, Enter) |
| supply voltage | AC100~240V, 50/60Hz or DC20~30V |
| Transformer shell model | Aluminum alloy IP65 |
| Transformer installation method | Wall installation or pipeline installation |
| Transformer external dimensions | H140×W137×D68mm(IP65) |