Fully automatic insulation boot glove withstand voltage leakage current testerDL408 "Electricity Safety Work Regulations" specifies the testing methods and cycles for commonly used safety tools such as insulated boots and gloves, which are safety protection equipment for power system operation and maintenance. The voltage withstand test for insulated boots and gloves shall be conducted every six months, during which no breakdown is allowed, and the leakage current of the insulated boots shall not exceed the limit value.
Main functions:
1.1Fully automatic insulation boot glove withstand voltage leakage current testerSimultaneously conduct a test on 8 insulated boots or gloves and measure the leakage current separately.
1.2 It adopts a large screen LCD display with full Chinese characters, which displays a large amount of information. One screen simultaneously displays parameters such as 8 high-voltage leakage currents, test voltage, current, timing time, etc.
1.3 It can measure parameters such as test voltage and primary current of the test transformer.
1.4 Use infrared communication technology to isolate the control panel from the high-voltage system, ensuring the safety of the testing personnel.
1.5 Fully automatic voltage withstand test. After the experiment begins, the instrument automatically closes and boosts the voltage at the required speed according to the national standard. It starts timing and maintaining the test voltage when it reaches the predetermined voltage. When the time is up, it automatically drops to zero and cuts off the power. At the same time, it displays the leakage current of each test sample and automatically saves the test results.
1.6 Equipped with a grounded container for easy operation.
1.7 Each test sample is equipped with a high-voltage breaking mechanism. When any one of the circuits breaks down, the test sample will automatically detach from the high voltage without affecting the progress of the test.
1.8 has overvoltage and overcurrent protection functions.
1.9 Equipped with high-voltage hazard warning light display.
1.10 can save 60 sets of experimental data and results for easy access at any time.
1.11 Real time calendar clock function.
Product parameters:
Rated output voltage: 50kV
Rated capacity: 5kVA
Output voltage range: 50.0 kV (250V)
Voltage measurement error: < ± (0.2% U+0.02% Umax),
Where U is the indication value and Umax is the upper limit value of the measurement range
Input current range: 25.0A
Current measurement error: < ± (0.2% I+0.02% Imax),
Where I is the displayed value and Imax is the upper limit of the measurement range
Leakage current range: 25.00mA
Leakage current measurement error: ± (0.5% I+2 words),
Where I is the indication value
Leakage current resolution: 0.01 mA
Digital timer: 10~990 seconds
Maintenance and upkeep:
After using the device, the water in the sink should be drained completely.
If not used for a long time, the inside and outside of the sink should be kept dry, and the electrode rod and insulation rod should be free of moisture.
Before use, the insulation resistance of the insulation rod should be measured, and if necessary, the withstand voltage value should not be lower than 20KV when tested with high voltage.