E-mail
2663596212@qq.com
-
Phone
13621915063,13681929324
-
Address
No. 14, Lane 466, Jiangyang South Road, Zhabei District
Shanghai Shengxu Electric Co., Ltd
2663596212@qq.com
13621915063,13681929324
No. 14, Lane 466, Jiangyang South Road, Zhabei District
UATX-HI Insulated Boots (Gloves) Voltage Test Device (Automatic)It is a device for conducting AC withstand voltage tests on insulated boots and gloves. It can simultaneously test three pairs of insulated boots (gloves) and read the leakage current of each one.
Main features:
1. The voltage withstand test device for insulated boots and gloves has a fast testing speed, which improves work efficiency
2. Direct reading of withstand voltage and high voltage leakage current, and automatic identification of non-conforming samples, with a high degree of intelligence
3. Can simultaneously test 3 pairs of insulated boots and gloves, and can read the leakage current of each one to accurately determine the unqualified insulated boots and gloves
4UATX-HI Insulated Boots (Gloves) Voltage Test Device (Automatic)The bottom of the structure is equipped with casters, which can be moved freely
Technical parameters:
| model | UATX-HI | |
| name | Insulated boots (gloves) voltage withstand test device (automatic) | |
| INPUT VOLTAGE | AC220V 50Hz | |
| Output voltage | 0~30kV | |
| capacity | 3kVA | |
| Number of tests | 6 pieces each time | |
| Measurements | Can display and print the voltage value of each test sample; Leakage current value | |
| function | Overcurrent protection, overvoltage protection, custom time, voltage, leakage current value | |
| LCD display, fully Chinese menu operation, with printing | ||
| Measurement accuracy | Voltage ± 2% (± 3 words) | Current ± 2% (± 3 words) |
| weight | Insulated boots (gloves) operating box 12kg power frequency withstand voltage test bench 60kg | |
| External dimensions (control box) | 400*280*350mm3 | |
| Weight (control box) | 25kg | |
| External dimensions | 1150*750*700mm3 | |
| weight | 40kg | |
Maintenance and upkeep:
After using the device, the water in the sink should be drained completely.
If not used for a long time, the inside and outside of the sink should be kept dry, and the electrode rod and insulation rod should be free of moisture.
Before use, the insulation resistance of the insulation rod should be measured, and if necessary, the withstand voltage value should not be lower than 20KV when tested with high voltage.
Equipment completeness:
1. One copy of the user manual
2. One certificate of conformity
3. One sink device
4. One base
5. One test transformer withstand voltage table