Welcome Customer !

Membership

Help

Chengdu Hengshengyuan Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Chengdu Hengshengyuan Technology Co., Ltd

  • E-mail

    cdysyb@163.com,@qq.com

  • Phone

    18908016281,13980818230

  • Address

    No. 1001, Zone A, No. 1299 Tianfu Avenue South, High tech Zone, Chengdu City

Contact Now

HT200AX anti-corrosion static pressure level gauge

NegotiableUpdate on 09/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

HT200AX anti-corrosion static pressure level gauge is mainly a new generation static pressure level gauge designed for strong acid and alkali environments. The anti-corrosion liquid level gauge is suitable for large-diameter ceramic capacitive pressure sensors, which is beneficial for preventing the condensation of corrosive liquids All sensor cables are made of high-quality corrosion-resistant materials, with a fully enclosed structure and no mechanical sealing. Application areas: Liquid levels of various conductive media such as reservoirs, sewage, bathhouses, acid-base solutions, and low-pressure boilers

Product Details

• Fully digital intelligent instrument.
• With 4 limit switch node outputs, the control domain can be set arbitrarily, and each limit can be
Set arbitrarily within the measurement range.
• The base point value can be set arbitrarily (i.e. the value or variation to be displayed on the instrument when the transmitter is at zero position)
The altitude at which the transmitter is installed.
• Standard serial RS232/RS485 digital interface; Completely isolated current and voltage output.
Pull out design, the instrument movement can be extracted from the housing for easy maintenance and replacement of the instrument
For standard transmitter signal input, the instrument can be passively calibrated on site for easy transmission
Exchange of equipment and on-site debugging


Range: 0-50 meters

Accuracy: ± 0.25% FS

Long term stability: ± 0.15% FS/year

Temperature coefficient: ± 0.1% F.S

Protection level: junction box and header: IP67

Probe: IP68

Temperature: -40~150 ℃

Relative humidity: 0~100%

Analog output: two-wire system 4-20mA

Power supply: 24VDC ± 10%

Number of control points: 4NO (normally open)+4NC (normally closed) dry contacts

Indicator lights: upper limit, upper limit, lower limit, lower limit

Transmitter size: 232 × 183 × 155mm

Connection method: M20 × 1.5 external thread

Accessory diagram Model and parameters Remarks

HT200AX-TM static pressure sensor with output display box (junction box)

Can be used independently, outputting 4-20mA corresponding to the liquid level

Probe: PTFE+stainless steel material

HT200M on-site liquid level control display ABS shell design

Installation requirements
When installing the transmitter, the height of the storage container should be determined first, and the installation position of the transmitter and the length of the air guide cable should be determined according to the actual situation on site. Then, the transmitter should be vertically suspended at an appropriate height or installed in a bracket style, so that the transmitter is at a certain height away from the bottom to prevent sediment and dirt from blocking the pressure sensing part. The transmitter should be kept as far away as possible from the heating pipe or mixing source.

When installed in still water, such as deep wells or pools, the measuring part is usually directly immersed in the water for measurement. If conditions permit, the method of inserting steel pipes or PVC pipes can be used. The inner diameter of the pipe is about Φ 45mm, and several small holes are drilled at different heights of the pipe to allow water to enter the pipe smoothly.

As shown in the following figure: