HX2010 Insulation Resistance Tester

NegotiableUpdate on 10/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HX2010 insulation resistance tester adopts an embedded industrial microcontroller real-time operating system, and the ultra-thin wire head is perfectly combined with a graphic dot matrix LCD display. This series of meters has multiple voltage output levels (500V, 1000V, 2500V, 5000V), large capacity, and strong anti-interference ability

Product Details

Product Introduction
The HX2010 insulation resistance tester adopts an embedded industrial microcontroller real-time operating system, and the ultra-thin wire head is perfectly combined with a graphic dot matrix LCD display. This series of meters has multiple voltage output levels (500V, 1000V, 2500V, 5000V), large capacity, strong anti-interference, finger and digital synchronous display, AC/DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), and various measurement results with anti power loss function. It is an ideal testing instrument for measuring insulation resistance of large capacity transformers, mutual inductors, generators, high-voltage motors, power capacitors, power cables, lightning arresters, and other devices.

Product features
Ø There are multiple voltage output options (500V, 1000V, 2500V, 5000V), and the measurement resistance range can reach 0-200G Ω. The resistance range can be automatically converted and there are corresponding indications.
Two ways to synchronously display insulation resistance. The mechanical pointer adopts an ultra-thin wire structure with strong seismic resistance. The use of mechanical pointers can easily observe the range of changes in insulation resistance, while the use of dot matrix LCD screens can guide users in operating the instrument and accurately obtain measurement results.
The mechanical meter head and LCD screen are combined into one. Dual scale display, automatic range conversion. The colored scale is easy to read and has LED display for corresponding colors.
Adopting embedded industrial microcontrollers and real-time operating software systems. High degree of automation and strong anti-interference ability, the instrument can automatically calculate absorption ratio and polarization index without manual intervention.
The user interface is user-friendly, and various measurement results have anti power failure function, which can store measurement results continuously for 20 times.
When the instrument generates high pressure, there is a prompt sound output.
Built in residual high voltage discharge circuit, which can automatically discharge the residual high voltage on the tested equipment after testing.
Dual use AC/DC, equipped with rechargeable battery and AC adapter.
The instrument adopts a portable design for easy field operation.
Ø High voltage short-circuit current ≥ 3mA is an ideal testing instrument for measuring insulation resistance of large transformers, transformers, generators, high-voltage motors, power capacitors, power cables, lightning arresters, etc.

Main technical indicators
model HX2010
output voltage 500V DC 1000V DC 2500V DC 5000V DC
essence
degree
temperature 23℃±5℃
insulation resistance 1MΩ~20GΩ
±5%
2MΩ~40GΩ
±5%
5MΩ~100GΩ
±5%
10MΩ~200GΩ
±5%
output voltage 4MΩ~20GΩ
0~+10%
8MΩ~40GΩ
0~+10%
20MΩ~100GΩ
0~+10%
40MΩ~200GΩ
0~+10%
High voltage short-circuit current ≥3mA
working power supply 8 AA rechargeable batteries, external charging adapter
Working temperature and humidity -10 ℃~40 ℃, maximum relative humidity 85%
Storage temperature and humidity -20 ℃~60 ℃, maximum relative humidity 90%
insulation performance When the voltage between the circuit and the casing is 1000V DC, the maximum is 2000M Ω
pressure resistance When the voltage between the circuit and the casing is 2500V AC, withstand for 1 minute
size 230mm×190mm×90mm (L×W×H)
weight 2KG
Attachment One set of testing cables, instruction manual, certificate of conformity, charging adapter power cord
model HX2010
output voltage 500V DC 1000V DC 2500V DC 5000V DC
essence
degree
temperature 23℃±5℃
insulation resistance 1MΩ~20GΩ
±5%
2MΩ~40GΩ
±5%
5MΩ~100GΩ
±5%
10MΩ~200GΩ
±5%
output voltage 4MΩ~20GΩ
0~+10%
8MΩ~40GΩ
0~+10%
20MΩ~100GΩ
0~+10%
40MΩ~200GΩ
0~+10%
High voltage short-circuit current ≥3mA
working power supply 8 AA rechargeable batteries, external charging adapter
Working temperature and humidity -10 ℃~40 ℃, maximum relative humidity 85%
Storage temperature and humidity -20 ℃~60 ℃, maximum relative humidity 90%
insulation performance When the voltage between the circuit and the casing is 1000V DC, the maximum is 2000M Ω
pressure resistance When the voltage between the circuit and the casing is 2500V AC, withstand for 1 minute
size 230mm×190mm×90mm (L×W×H)
weight 2KG
Attachment One set of testing cables, instruction manual, certificate of conformity, charging adapter power cord