Dielectric loss measurement is a fundamental method in insulation testing, which can effectively detect the overall moisture degradation and deterioration of electrical equipment insulation, as well as local defects. Widely used in electrical manufacturing, electrical equipment installation, handover, and preventive testing. The measurement of dielectric loss of transformers, mutual inductors, reactors, capacitors, bushings, lightning arresters, etc. is the most basic method to measure their insulation performance.
Product Details
Product Introduction
Dielectric loss measurement is a fundamental method in insulation testing, which can effectively detect the overall moisture degradation and deterioration of electrical equipment insulation, as well as local defects. Widely used in electrical manufacturing, electrical equipment installation, handover, and preventive testing. The measurement of dielectric loss of transformers, mutual inductors, reactors, capacitors, bushings, lightning arresters, etc. is the most basic method to measure their insulation performance. The HXJS-V anti-interference dielectric loss tester breaks through the traditional bridge measurement method, adopts variable frequency power supply technology, and uses microcontrollers and modern electronic technology for automatic frequency conversion, analog-to-digital conversion, and data operation; Achieve strong anti-interference ability, fast testing speed, high accuracy, fully automatic digitization, and easy operation; The power supply adopts a high-power switching power supply, which outputs pure sine waves at 45Hz and 55Hz, automatically applies voltage, and can provide a maximum voltage of 10 kV; Automatically filter out 50Hz interference, suitable for on-site testing in substations and other areas with high electromagnetic interference. Widely applicable for dielectric loss measurement of transformers, mutual inductors, bushings, capacitors, lightning arresters and other equipment in the power industry.
Product features
The instrument adopts the complex current method to measure capacitance, dielectric loss, and other parameters. The test results have high accuracy, making it easy to achieve automated measurement.
The instrument adopts frequency conversion technology to eliminate on-site 50Hz power frequency interference, and can measure reliable data even in strong electromagnetic interference environments.
The instrument adopts a large screen LCD display, and the testing process is both intuitive and easy to operate through Chinese character menu prompts.
The instrument is easy to operate, and the measurement process is controlled by a microprocessor. As long as the appropriate measurement method is selected, the data measurement can be automatically completed under the control of the microprocessor.
Ø Integrated model, equipped with standard capacitors and high-voltage power supply for easy on-site testing and reducing on-site wiring.
Ø The instrument has high measurement accuracy and can meet the requirements of oil dielectric loss measurement. Therefore, only a standard oil cup and a dedicated testing line are needed to achieve oil dielectric loss measurement.
Equipped with CVT testing function, it can achieve self-excited testing of CVT without the need for external accessories. Only one measurement is required to measure the capacitance and dielectric loss of C1 and C2. Can achieve CVT ratio testing.
The reverse wiring test adopts IVDDV technology, eliminating the previous phenomenon of unstable reverse wiring data.
Ø Equipped with reverse wiring low-voltage shielding function, C11 can perform 10kV reverse wiring dielectric loss measurement without disconnecting the wire when the 220kV CVT bus is grounded
Ø It has the function of measuring high voltage dielectric loss and can use high-voltage transformers or series resonance to conduct dielectric loss tests exceeding 10kV voltage.
Ø Grounding protection function: When the instrument is not grounded or poorly grounded, it will not enter the normal program and will not output high voltage. The overcurrent protection function ensures that the instrument is not damaged in the event of a short circuit or breakdown of the test sample.
Ø Electric shock protection function: When the instrument operator accidentally gets an electric shock, the instrument will immediately cut off the high voltage to ensure the safety of the test personnel.
Main technical indicators
Ø Accuracy: Cx: ± (reading x 1%+1pF) tg δ: ± (reading x 1%+0.00040)
Ø Anti interference index: Frequency conversion anti-interference, can still achieve the above accuracy under 200% interference
Ø Capacity range:
Internal high voltage: 3pF~60000pF/10kV 60pF~1 μ F/0.5kV
External high voltage: 3pF~1.5 μ F/10kV, 60pF~30 μ F/0.5kV
Ø Resolution: up to 0.001pF, 4 significant digits
Ø tg δ range: unlimited, resolution 0.001%, automatic identification of three types of samples: capacitance, inductance, and resistance.
Ø Test current range: 10 μ A~5A
Ø Internal high voltage: Set voltage range: 0.5-10kV Voltage resolution: 1V Accuracy: 2%
Ø Maximum output current: 200mA
Ø Voltage rise and fall method: continuous smooth adjustment
Ø Test frequency:
45, 50, 55, 60, 65Hz single frequency
45/55Hz, 55/65Hz, 47.5/52.5Hz automatic dual frequency conversion
Ø Frequency accuracy: ± 0.01Hz
External high pressure:
The maximum test current during positive wiring is 5A, with a frequency range of 40-70Hz for power frequency or variable frequency
The maximum test current during reverse wiring is 10kV/5A, with a frequency range of 40-70Hz for power frequency or variable frequency
CVT self-excited low voltage output: output voltage 3-50V, output current 3-30A
Ø CVT ratio measurement:
Variable ratio measurement accuracy: ± reading × 1% Variable ratio measurement range: 10~99999
Phase measurement accuracy: ± 0.1 ° Phase measurement range: 0-359.99 °
Ø Measurement time: about 36 seconds, depending on the measurement method
Input power supply: 180V~270VAC, 50Hz ± 1%, powered by mains or generator
Ø Computer interface: Standard RS232 interface
Ø Printer: Brilliance A7 Thermal Micro Printer
Environmental temperature: -10 ℃ to 50 ℃
Relative humidity:<90%
Ø Dimensions: 460 × 360 × 350mm
Instrument weight: 28kg
Ø Accuracy: Cx: ± (reading x 1%+1pF) tg δ: ± (reading x 1%+0.00040)
Ø Anti interference index: Frequency conversion anti-interference, can still achieve the above accuracy under 200% interference
Ø Capacity range:
Internal high voltage: 3pF~60000pF/10kV 60pF~1 μ F/0.5kV
External high voltage: 3pF~1.5 μ F/10kV, 60pF~30 μ F/0.5kV
Ø Resolution: up to 0.001pF, 4 significant digits
Ø tg δ range: unlimited, resolution 0.001%, automatic identification of three types of samples: capacitance, inductance, and resistance.
Ø Test current range: 10 μ A~5A
Ø Internal high voltage: Set voltage range: 0.5-10kV Voltage resolution: 1V Accuracy: 2%
Ø Maximum output current: 200mA
Ø Voltage rise and fall method: continuous smooth adjustment
Ø Test frequency:
45, 50, 55, 60, 65Hz single frequency
45/55Hz, 55/65Hz, 47.5/52.5Hz automatic dual frequency conversion
Ø Frequency accuracy: ± 0.01Hz
External high pressure:
The maximum test current during positive wiring is 5A, with a frequency range of 40-70Hz for power frequency or variable frequency
The maximum test current during reverse wiring is 10kV/5A, with a frequency range of 40-70Hz for power frequency or variable frequency
CVT self-excited low voltage output: output voltage 3-50V, output current 3-30A
Ø CVT ratio measurement:
Variable ratio measurement accuracy: ± reading × 1% Variable ratio measurement range: 10~99999
Phase measurement accuracy: ± 0.1 ° Phase measurement range: 0-359.99 °
Ø Measurement time: about 36 seconds, depending on the measurement method
Input power supply: 180V~270VAC, 50Hz ± 1%, powered by mains or generator
Ø Computer interface: Standard RS232 interface
Ø Printer: Brilliance A7 Thermal Micro Printer
Environmental temperature: -10 ℃ to 50 ℃
Relative humidity:<90%
Ø Dimensions: 460 × 360 × 350mm
Instrument weight: 28kg