Intelligent vortex flowmeter

NegotiableUpdate on 01/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Specially designed for measuring saturated steam, it can automatically compensate for the density of saturated steam. Integrate flow and temperature compensation sensors into one. The sensing head is a field detachable body that can be replaced without affecting the fluid flow inside the pipeline.
Product Details


1、 Product Overview of Temperature Compensated Vortex Flow Meter
Specially designed for measuring saturated steam, it can automatically compensate for the density of saturated steam. Integrate flow and temperature compensation sensors into one. The sensing head is a field detachable body that can be replaced without affecting the fluid flow inside the pipeline.
2、 Main characteristics of temperature compensated vortex flowmeter
Through integrationTemperature pressure compensation vortex flowmeterIt can display the instantaneous mass flow rate, cumulative flow rate, temperature, pressure, etc. of saturated steam. The steam temperature can also be manually set, and the temperature and vortex sensor head can be replaced without stopping the fluid inside the tube.
IIITechnical parameters of temperature compensated vortex flowmeter
● Measurement medium
Saturated steam, water
● Nominal caliber
DN25 — DN500
● Medium temperature
- 40℃—+150℃ ; -40℃—+280℃ ; -40℃—+350℃ ;
-40 ℃ -+420 ℃ (requires optional sensor head with continuous flow disassembly type)
● Accuracy level
1.5 level, 1.0 level (optional), 0.5 level, 0.2 level (supply by agreement required)
● Measurable flow range of vortex street
液体: 0.4 m/s —10 m/s
Gas and steam: 4m/s -70 m/s
● Amplifier selection
Temperature compensation integrated intelligent digital display amplifier (working condition pulse or RS485 signal output)
Explosion proof rating
Intrinsic safety explosion-proof Exia Ⅱ CT4
Explosion proof Exd Ⅱ CT6
● Protection level
IP54、IP65
● Body material
1Cr18Ni9Ti (supplied under other material agreements)
4、 Model and Function Selection of Temperature Compensated Vortex Flow Meter
JK-KF83 Full Tube Vortex Flow Sensor
JK-KF83 Full Tube Vortex Street Body Connection Form
1. Flange connection type (temperature and pressure compensation type vortex street must be selected)
2-flange card mounting type (optional)
B-Measurable medium
1 Gas, liquid, steam universal (limited to digital filtering intelligent display vortex street)
2. Measuring liquids
3 Measurement of gas
Measure saturated steam and superheated steam
C-vortex caliber
D-output signal
0 voltage pulse (low level ≤ 1V, high level ≥ 6V, pulse width ≥ 10uS)
1. Two wire 4-20mA output (temperature and voltage compensation type is a three wire system)
2 No signal output on-site display
E - Measurable high medium temperature
0 -40℃…+150℃
1-40 ℃...+280 ℃ (LUCB type plug-in vortex street 250 ℃)
2-40 ℃...+350 ℃ (LUCB type plug-in vortex street not optional)
3-40 ℃...+420 ℃ (only applicable to sensor head with continuous flow disassembly type)
F - Explosion proof grade
No explosion-proof certification, protection level is IP54, IP65
1 security explosive type, explosion-proof level Exia Ⅱ CT4
2 explosion-proof type, explosion-proof grade Exd Ⅱ CT6
G-Vortex Amplifier Display Form
0 No on-site display type
On site display type (LCD display, can display instantaneous flow rate, cumulative flow rate, compensation type can also display temperature, pressure, standard flow rate, etc.)
H-Instrument accuracy level
0 1.0 level (LUGB type is optional, LUCB type requires agreement supply)
1 0.5 level (limited to LUGB type vortex street)
2 0.2 level (limited to LUGB type vortex street, supply by agreement required)
Level 3 2.5 (LUCB type plug-in vortex street optional)
4 1.5 level (LUCB type plug-in vortex street requires agreement supply)
5 low velocity vortex street (directly reduced diameter inside the body, accuracy ≥ 1.5 level)
Installation form of I-amplifier
0 body and amplifier not separated type
1. Body and amplifier separation type (separation distance ≤ 10 meters. Temperature and temperature pressure compensation type body is not optional)
2 Submersible Vortex Streets
J-Vortex amplifier working power supply
0 12VDC power supply
1 24VDC power supply
2 3.6V (or 3V) lithium battery power supply (limited to vortex street with LCD display and no signal output)
3 3.6V (or 3V) lithium battery, 24VDC power supply simultaneously (limited to vortex street with LCD display and signal output)
Note: 3V lithium battery is only suitable for temperature and pressure compensation integrated vortex street
K-vortex detection function and amplifier display form
0 uncompensated (without temperature or pressure compensation function)
On site display of gas temperature and pressure compensation integrated intelligent (LUGB type flange connected gas meter body * *). It can display instantaneous flow rate, cumulative flow rate, temperature, pressure or frequency, time, etc. under standard conditions. Three wire 4-20mA output and voltage pulse output can be selected simultaneously before or after compensation, with pulse low level ≤ 1V, high level ≥ 6V, and pulse duty cycle of 50%
On site display of superheated steam temperature and pressure compensation integrated intelligent (LUGB type flange connected superheated steam, saturated steam meter body * *). Density compensation calculation can be performed. It can display instantaneous mass flow rate, cumulative mass flow rate, temperature, pressure or operating volume, frequency, etc. Three wire 4-20mA output and voltage pulse output can be selected simultaneously before or after compensation, with pulse low level ≤ 1V, high level ≥ 6V, and pulse duty cycle of 50%
On site display temperature compensation intelligent type (LUGB saturated steam table body * *, capable of density compensation calculation). It can display instantaneous mass flow rate, cumulative mass flow rate, temperature, pressure, etc. Optional compensation * * wire based voltage pulse output, pulse low level ≤ 1V, high level ≥ 6V, pulse duty cycle 50%)
JK-KKF83Installation form of full tube vortex street sensing head
0 Sensor Head Cut off Disassembly Type
1 Sensor head continuous flow detachable type (≥ 350 ℃ vortex street required type)
M-Communication Method
0 No communication
R485 communication (only applicable to intelligent amplifiers)
2 R232 communication (only applicable to intelligent amplifiers)
N-HART protocol
0 No HART protocol
1. Equipped with HART protocol (protocol supply required)
Q-filtering method
0 Normal Method
1. Intelligent digital filtering method (protocol supply required)