Welcome Customer !

Membership

Help

Suzhou Neway Analytical Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Suzhou Neway Analytical Instrument Co., Ltd

  • E-mail

    yang.yi@niumag.com

  • Phone

    18516712219

  • Address

    No. 97 Qinglian Road, Huguan Industrial Zone, Suzhou City

Contact Now

Nuclear Magnetic Resonance Core Analyzer - Suzhou

NegotiableUpdate on 12/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The nuclear magnetic resonance core analysis technology has the characteristics of non-destructive, fast, and accurate, which can effectively characterize the development characteristics and distribution status of core pores and microcracks, obtain rock physical parameters such as porosity and permeability, as well as the occurrence status and pore structure information of fluids inside the rock matrix. The MacroMR series also innovatively supports pseudo triaxial testing function, achieving a perfect integration of nuclear magnetic technology and traditional mechanical experiments, enabling researchers to conduct triaxial damage experiments and stress-strain experiments, and characterize the micro pore development process through nuclear magnetic technology.
Product Details

Accurate and rapid analysis of core samples is crucial in the field of energy exploration and development. Suzhou Neway Analytical Instrument Co., Ltd., as a leading enterprise in low field nuclear magnetic resonance technology in China, is providing strong technical support and solutions for geological research, oil and gas exploration, and other fields with its independently developed series of nuclear magnetic resonance core analyzers.

Suzhou Neway Analytical Instrument Co., Ltd. has been dedicated to the development and application promotion of "nuclear magnetic resonance" technology since its establishment in 2003. We have successively developed multiple series of professional low field nuclear magnetic resonance equipment with independent intellectual property rights.The nuclear magnetic resonance core analysis technology has the characteristics of non-destructive, fast, and accurate, which can effectively characterize the development characteristics and distribution status of core pores and microcracks, obtain rock physical parameters such as porosity and permeability, as well as the occurrence status and pore structure information of fluids inside the rock matrix.

Based on profound industry insights and diversified needs for scientific research and field applications, Neway has built a complete product system for nuclear magnetic resonance core analyzers. Its core advantages are reflected in a highly customized software ecosystem and leading hardware performance.

The company has customized professional software packages for different application scenarios, including powerful data analysis software and dedicated core analysis platforms, greatly improving research accuracy and on-site efficiency. The instrument is equipped with rich one-dimensional, two-dimensional, and imaging pulse sequences, and is open to users, providing great methodological freedom for cutting-edge scientific exploration.

MacroMR Series Large Aperture Magnetic Resonance Imaging Analyzer

The overall design is in a cabinet style, with a simple and elegant appearance. It adopts a C-type large cavity magnet with a wide range of applications, equipped with a push-pull injection design, and integrates nuclear magnetic resonance relaxation analysis and imaging functions. The unique large-diameter advantage of this series of products allows it to accommodate 1-6 inch full-size probes, perfectly adapting to the testing needs of different specifications of samples. The configured long core gripper can support a maximum sample length of 250mm, greatly expanding the range of measurable samples. The equipment comes standard with a temperature and pressure environment of 100 ℃ and 40Mpa, and can be customized and upgraded to extreme conditions of 150 ℃ and 70Mpa, and even up to 200 ℃ and 100Mpa. It can accurately simulate various actual reservoir environments. Its low-temperature support capability can be as low as -30 ℃, providing significant advantages for freeze-thaw experiments and special scenario simulations.

The MacroMR series also innovatively supports pseudo triaxial testing function, achieving a perfect integration of nuclear magnetic technology and traditional mechanical experiments, enabling researchers to conduct triaxial damage experiments and stress-strain experiments, and characterize the micro pore development process through nuclear magnetic technology. The application of constant gradient layer selection technology makes it possible to select different gradients, which is suitable for diverse structures and sample types. It enables accurate testing of sample layering and determination of pore structures at different levels, providing a new technological path for micro dynamic detection.

核磁共振岩心分析仪-苏州


Basic Parameters

Product models: MacroMR12-150H-I, MacroMR12-150H-HTHP (40Mpa-PMMR), MacroMR12-110H-I

Magnetic field strength: 0.3T ± 0.03T

Magnet uniformity: ≤ 50ppm

Magnet shape: C-shaped open type

Injection direction: horizontal/vertical

Product features


T1/T2 relaxation spectrum determination, T1/T2/proton density weighted image
Application of temperature, pressure, and fluid field (requires attachment support)

Product Application

1. Reservoir physical property analysis

Porosity/pore size distribution

Oil/water saturation

Saturation of movable/confined fluid

permeability

Wettability evaluation/Layered moisture content

2. Evaluation of oil and gas reservoir development

Quantitative testing and analysis of crack development during hydraulic fracturing process

Online analysis of pore development during acidification process

Online testing and analysis of polymer flooding and chemical flooding

Analysis and Evaluation of High Temperature and High Pressure Visual Displacement Experiment of Oil Water Two Phase

Analysis of micro pore permeability parameters under load (confining pressure/water pressure) conditions

Analysis of three-axis compression damage

Analysis of Infiltration and Absorption Process and Characteristics

3. Unconventional energy sources

Isothermal adsorption desorption of shale gas/coalbed methane

CO2 Competitive Adsorption Experiment

Formation/decomposition of natural gas hydrates

Analysis of Gas Water Two Phase Dynamic Displacement

Supercritical CO2 fracturing/gas displacement

MesoMR series medium-sized magnetic resonance imaging analyzer

This series comes standard with 1-4 inch precision probes, ensuring sample adaptability while achieving more accurate magnetic field uniformity and signal sensitivity. Standard configuration includes a stable working environment of 100 ℃ and 40Mpa, and can be upgraded to a high specification configuration of 150 ℃ and 70Mpa. With professional mechanical coupling analysis capabilities and high-precision detection technology, it provides an excellent technical platform for fine core analysis.

核磁共振岩心分析仪-苏州


Basic Parameters

Product models: MesoMR12-060H-I, MesoMR23-060H-I

Magnetic field strength: 0.3 ± 0.03T/0.5 ± 0.03T

Magnet uniformity: ≤ 30ppm

Maximum sample detection range: Ø 60mm * H100mm cylindrical body

Injection direction: Horizontal

Magnet shape: mouth shaped closed type

Product features

T1/T2 relaxation spectrum determination, T1/T2/proton density weighted image

Application of temperature, pressure, and fluid field (requires attachment support)

Product Application

1. Reservoir physical property analysis

Porosity/pore size distribution

Oil/water saturation

Saturation of movable/confined fluid

permeability

Wettability evaluation

2. Evaluation of oil and gas reservoir development

Quantitative testing and analysis of crack development during hydraulic fracturing process

Online testing and analysis of polymer flooding and chemical flooding

Analysis and Evaluation of High Temperature and High Pressure Visual Displacement Experiment of Oil Water Two Phase

Analysis of micro pore permeability parameters under load (confining pressure/water pressure) conditions

Online analysis of pore development during acidification process

Analysis of three-axis compression damage

3. Unconventional energy sources

Isothermal adsorption desorption of shale gas/coalbed methane

CO2 Competitive Adsorption Experiment

Formation/decomposition of natural gas hydrates

Analysis of Gas Water Two Phase Dynamic Displacement

Supercritical CO2 fracturing/gas displacement

MicroMR series nuclear magnetic resonance core analyzer

The MicroMR series nuclear magnetic resonance core analyzer adopts a breakthrough portable design, which ensures the detection performance of Zhuoyue while achieving on-site testing, freeing it from dependence on fixed laboratories. The uniformity of the magnet in this instrument reaches ≤ 30ppm, with small measurement errors and high accuracy, providing a reliable data foundation for high-quality scientific research. Its shortest echo time (TE) can reach 60 μ s, effectively capturing short relaxation signals and significantly improving weak signal detection capabilities, providing a new technological path for fine analysis of complex core samples. The advanced dual adjustable probe technology adopted effectively suppresses the interference of different samples on the test results, combining high signal-to-noise ratio and high accuracy, further ensuring the reliability of the data.

核磁共振岩心分析仪-苏州


Basic Parameters

Product models: MicroMR12-025V, MicroMR12-040V, MicroMR02-025V, MicroMR02-040V

Magnetic field strength: 0.28T ± 0.03T/0.05T ± 0.005T

Magnet uniformity: ≤ 30ppm

Maximum sample detection range: 1.5 inches

Product Features

1. Fast, non-destructive, compact and portable

2. Multiple field strengths to choose from, two specialized probes to choose from, one machine with multiple parameters

3. Suitable for various types of rock cores and debris

4. The instrument has high precision, good repeatability, and stable performance

Product Application

Fluid identification in complex reservoir pore media

Physical properties of core reservoirs, porosity/pore size distribution

Oil/water saturation

Saturation of movable/confined fluid

Penetration rate prediction

Wettability evaluation

Pore moisture and distribution characteristics

Pre sales service: in-depth experience, precise selection

Neway has a professional customer experience center, welcoming customers to visit the site, have zero distance contact and operate the equipment, and intuitively feel its performance and usability. Through on-site experience and professional explanations from senior consultants, we help customers accurately evaluate whether the equipment meets their application needs.

After sales support: fast response, professional guarantee

Quick response mechanism: We promise to respond within 4 hours and provide a solution within 8 hours. If remote solutions are not possible, engineers will arrive within 24 hours in provincial capitals and 72 hours in remote areas, including holidays. Ensure that users receive timely and effective handling when encountering problems, minimizing the impact of equipment downtime.

Professional team configuration: We have a highly educated service team of nearly 20 people, with master's degrees accounting for over 60%. We have a strong technical foundation and customized service capabilities to ensure that complex problems are solved professionally and efficiently.

Multiple communication channels: support telephone QQ、 WeChat and other various methods provide convenient and flexible communication, and can respond to customer needs at any time.

User training empowerment: Neway has established a normalized training system. In addition to holding regular application training courses, it also provides flexible online and offline daily training. Users can obtain software and hardware training videos anytime and anywhere through "Newmart Analysis", "Newmart Service" WeChat official account and "Nuclear Magnetic Research Energy Station" applet, so as to continuously improve operating skills and application level and maximize the value of equipment.

Proactive service culture: Adhering to the concept of "achieving customer success and taking responsibility", engineers actively follow up, proactively solve problems, help customers reduce unnecessary repair processes, and save time and energy. And continuously optimize service processes based on customer feedback, growing together with customers.

Device QR code identification: Each device is equipped with a QR code identification, and customers can quickly obtain online support entry by scanning the code, greatly improving service response efficiency and convenience.

Full dimensional service centers cover the whole country: Neway has 7 full dimensional service centers located in Shanghai, Suzhou, Chengdu, Guangzhou, Zhengzhou, Beijing, and Taiyuan, covering all regions of China, ensuring that service resources can quickly reach customers across the country.


Similar Product Recommend