Nernst 6000Online zirconia oxygen analyzer with blowdownFeatures:
Input function: One instrument can be equipped with a zirconia probe to display the measured oxygen content in real time.
Output control: The instrument is equipped with a 4-20mA current output signal.
Measurement range: Oxygen measurement range from 0 to 100% oxygen content.
● Alarm settings: The instrument has adjustable high and low oxygen alarm outputs.
● Automatic calibration: The instrument comes with an automatic calibration function, and users can customize the calibration time and frequency according to their needs.
● Automatic dust cleaning: The instrument has an automatic dust cleaning function for the probe, and users can perform dust cleaning on the probe at regular intervals according to their needs, eliminating the need for manual on-site dust cleaning.
Intelligent control: The instrument can have human-machine dialogue and complete various functions according to predetermined settings.
Display function: It can display the date, current oxygen content, probe temperature, current oxygen millivolt value, as well as 14 primary status displays and 11 secondary status displays required parameters.
● Safety function: When the furnace is stopped, the user can control the heater of the probe to be turned off to ensure safety during use.
● Easy installation: The instrument can be mounted on the wall with feet, and the connection between the instrument and the probe is made by a dedicated cable.
Nernst 6000Online zirconia oxygen analyzer with blowdownTechnical Specifications:
power supply |
Instrument power |
Probe heating method |
Probe heating temperature |
AC 85V~264V |
25W+600W (probe) |
PID control type |
720℃±5℃ |
display mode |
Oxygen measurement range |
Accuracy, repeatability |
reaction speed |
128X64 dot LCD display |
10 to the negative 38th power% (± 3 characters)~65% |
The instrument has a measurement accuracy of ± 1%. Repetitive accuracy ± 0.5% |
Non direct heating measurement takes about 3 seconds. Heat directly for 30 seconds. The core detection reaction speed is 0.0001 seconds. |
Correction and dust cleaning |
Input and output |
alarm function |
Reference gas |
|
The instrument has one automatic calibration function and one automatic dust cleaning function, Automatic control of solenoid valve switch |
Input: Zirconia sensor signal input Output: Linear 4-20mA DC |
High and low oxygen alarms can be set arbitrarily |
The instrument comes with a miniature brushless motor vibration pump for reference gas supply |
working environment |
Instrument size, weight |
interface operation |
Installation method |
|
Environmental temperature: -20~60 ℃ Not suitable for places with strong direct sunlight. |
(Width) 235mm × (Height) 230mm × (Thickness) 95mm Weight: 3.0 kilograms |
4 touch buttons |
Wall-mounted installation |