E-mail
627320610@qq.com
-
Phone
18610516470
-
Address
Room 303, Building F, Yida Technology Park, No. 11 Jinpu Road, Suzhou Industrial Park
Suzhou Frog Vision Sensing Technology Co., Ltd
627320610@qq.com
18610516470
Room 303, Building F, Yida Technology Park, No. 11 Jinpu Road, Suzhou Industrial Park

Optical ppb dissolved oxygen sensor
The new generation of ppb dissolved oxygen sensor from Frog Vision is based on the principle of fluorescence quenching. Blue light is irradiated onto the fluorescent oxygen molecule probe to excite red light. As the oxygen molecule is the quenching agent of the fluorescent probe, it can take away energy. Therefore, the time and intensity of the excited red light are inversely proportional to the concentration of the oxygen molecule. The dissolved oxygen sensor calculates the concentration of oxygen molecules by measuring the phase difference between the excited red light and the reference light, and combining it with a temperature compensated 3D calibration data model.
Advantages:
Smart sensor, all calibration parameters are stored inside the sensor, plug and play.
Optical technology eliminates the need for frequent replacement of membranes or replenishment of electrolyte solutions.
No preheating required, fast response speed, with a maximum response time of 30 seconds (T90).
The measurement process does not consume oxygen.
PTFE support material, resistant to certain solvents, with small drift and easy storage.
Our self-developed membrane, oxygen probe, and key components are all controllable.
RS485 digital output, supporting Modbus protocol.
• SS316,PVC, All titanium alloy shell, with multiple options available.
Optical ppb dissolved oxygen sensorTechnical Specifications
Measurement method: Fluorescence quenching method
Measurement range: 0-2000ppb (dissolved oxygen)
Resolution: 0.1ppb
Accuracy: ± 1 ppb or 3% reading, whichever is greater
Repeatability: ± 0.5ppb or 1.5% reading, whichever is greater, for 24 hours
Sample temperature range: 0~45 ℃
Detection limit: 0.8ppb
Calibration: 1-point calibration (zero point), in 99.999% nitrogen gas
Using water depth/pressure: 1-20bar (absolute pressure)
Power supply: 5-12V 25mA (normal)
Output: RS485, Modbus RTU protocol
Material: Titanium alloy (optional), SS316 (default), PVC
Size: 141.9mm in length (excluding cable connectors), 27mm in outer diameter
CIP cleaning: supported
Response time: 30 seconds T90 (in gas), 150 seconds T90 (in liquid), oxygen free to aerobic
Service life *: Sensor 2 years or more, sensing membrane 2 years or more
Maintenance and calibration frequency *: 6 months for sensors
Note: * The lifespan, maintenance, and calibration frequency are for reference only and depend on the actual usage environment.