Welcome Customer !

Membership

Help

Jiangsu Borui Measurement and Control Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Jiangsu Borui Measurement and Control Technology Co., Ltd

  • E-mail

    wxbrck@ 163.com

  • Phone

    13812024099

  • Address

    No. 35 Xigang East Road, Xishan District, Wuxi City

Contact Now

Platinum Ray Gas Turbine Flow Meter - Wuxi Platinum Ray Measurement

NegotiableUpdate on 11/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

1、 Overview: LWQ gas turbine flowmeter is a new intelligent instrument developed using advanced ultra-low power single-chip microcomputer technology, which integrates turbine flow sensor and display integration. It adopts dual row LCD on-site display, with compact structure, intuitive and clear reading, and can be used ..

Product Details

1、 Overview
The LWQ gas turbine flowmeter is a new intelligent instrument developed using advanced ultra-low power single-chip microcomputer technology, which integrates turbine flow sensors and display integration. It adopts dual row LCD on-site display and has obvious advantages such as compact structure, intuitive and clear readings, high reliability, no external power interference, lightning resistance, and low cost. The instrument has three-point correction of instrument coefficient, intelligent compensation of instrument coefficient nonlinearity, and can be corrected on site. The high-definition LCD display simultaneously displays instantaneous flow rate (4 significant digits) and cumulative flow rate (8 significant digits, with reset function). Keep all valid data intact for 10 years after power failure. This type of turbine flowmeter is an explosion-proof product with an explosion-proof rating of ExdIIBT6.
2、 Product features:
1. High precision, generally up to ± 1% R, ± 0.5% R, and high-precision models up to ± 0.2% R;
2. Good repeatability, short-term repeatability can reach 0.05%~0.2%. It is precisely because of its good repeatability that frequent calibration or online calibration can achieve extremely high accuracy, and it is the preferred flowmeter for settlement;
3. Equipped with three-point correction of instrument coefficients, intelligent compensation for instrument coefficient nonlinearity, and on-site correction capability
4. Keep all valid data intact for 10 years after power failure;
5. Wide range, with a medium to large caliber of up to 1:20 and a small caliber of 1:10;
6. Compact and lightweight structure, easy installation and maintenance, and high circulation capacity;
7. Suitable for high voltage measurement, there is no need to open holes on the instrument body, making it easy to make high voltage instruments;
8. Can be made into an insertion type, suitable for measuring large diameters, with low pressure loss, low price, can be removed without interruption, and easy installation and maintenance
9. There are various types of specialized sensors that can be designed according to the specific needs of users, such as low-temperature, bidirectional, downhole, sand mixing, etc;

3、 Technical parameters

execution standard

Gas turbine flowmeter (GB/T8940-2003)

Instrument caliber and connection method

20. 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300 are connected by flanges
25, 40, and 50 can be connected using threaded connections

accuracy class

± 1.5% R (± 1% R needs to be customized)*

turndown ratio

1:10 ; 1:20 ; 1:30

Instrument material

Table body: 304 stainless steel or cast aluminum
Impeller: anti-corrosion ABS or high-quality aluminum alloy
Converter: Cast aluminum

Terms of Use

Medium temperature: -20 ℃ to+80 ℃
Environmental temperature: -30 ℃ to+60 ℃
Relative humidity: 5% to 90%
Atmospheric pressure: 86Kpa to 106Kpa

working power supply

A. External power supply:+24VDC ± 15%, ripple ≤ ± 5%, suitable for 4-20mA output, pulse output, RS485, etc
B. Internal power supply: 1 set of 3.0V10AH lithium batteries, which can work normally when the battery voltage is between 2.0V and 3.0V.
Under voltage indication occurs when the voltage is below 2.0

Whole machine energy consumption

External power supply:<1W
Internal power supply: average power consumption ≤ 1W, can be used continuously for more than three years.

Signal output function

Pulse signal, 4-20mA current signal, control signal

Communication output function

RS485 communication

Real time recording function

Start stop record, diary record, and fixed time interval record

Signal wiring port

Internal thread M20 × 1.5 or other

Explosion-proof rating

Exd Ⅱ BT6 or Exia Ⅱ CT4

Protection level

IP65


4、 Measurement range and work pressure

Nominal Diameter
(mm)

model

Standard range
(m³/h)

Expand range
(m³/h)

Conventional voltage withstand level
(Mpa)

Specially designed high voltage level
(Mpa)

Installation method

DN20

LWQ-20

A

2.2-25

B

4-40

1.6

2.5,4.0

flange

DN25

LWQ-25

A

2.2-25

B

4-40

1.6

2.5,4.0

Flange (thread)

DN32

LWQ-32

A

5-50

B

6-60

1.6

2.5,4.0

flange

DN40

LWQ-40

A

5-50

B

6-60

1.6

2.5,4.0

Flange (thread)

DN50

LWQ-50

A1

6-65

B1

5-70

1.6

2.5,4.0

flange

LWQ-50

A2

10-100

B2

8-100

DN65

LWQ-65

A

15-200

B

10-200

1.6

2.5,4.0

flange

DN80

LWQ-80

A1

13-250

B

10-160

1.6

2.5,4.0

flange

LWQ-80

A2

20-400

flange

DN100

LWQ-100

A1

20-400

B

13-250

1.6

2.5

flange

LWQ-100

A2

32-650

flange

DN125

LWQ-125

1

25-700

B

20-800

1.6

2.5

flange

DN150

LWQ-150

A1

32-650

B

80-1600

1.6

2.5

flange

LWQ-150

A2

50-1000

flange

DN200

LWQ-200

A1

80-1600

B

50-1000

1.6

______

flange

LWQ-200

A2

130-2500

flange

DN250

LWQ-250

A1

130-2500

B

80-1600

1.6

______

flange

LWQ-250

A2

200-4000

flange

DN300

LWQ-300

1

200-4000

B1

130-2500

1.6

______

flange


5、 Product selection

product image

脉冲气体涡轮流量计

锂电池气体涡轮流量计

4-20MA气体涡轮流量计

Instrument model

LWQ-N

LWQ-A

LWQ-B

LWQ-C

LWQ-D

signal output

pulse

4-20mA

none

4-20mA

Optional 4-20mA/pulse

power supply

+24VDC±15%

+24VDC±15%

lithium battery

24VDC±15%

24VDC ± 15%+lithium battery

accuracy class

Level 2.5-1.5

Level 1.5-1.0

Level 1.5-1.0

measurement range

Standard range

Standard range or extended range

Standard range or extended range

monitor

none

have

have

temperature and pressure compensation

none

none

have

communication interface

none

none

RS485

Real-time recording

none

none

have

Instrument material

Aluminum alloy or stainless steel

Aluminum alloy or stainless steel

Aluminum alloy or stainless steel

Explosion-proof rating

ExdIIBT6 or ExiaICIT4

ExdIIBT6 or ExiaICIT4

ExdIIBT6 or ExiaICIT4

Protection level

IP65

IP65

IP65

Total power consumption

< 1W

< 1W

< 1W

Instrument communication

DN25~DN300

DN25~DN300

DN25~DN300

Installation method

Flange installation

Flange installation

Flange installation

medium temperature

-20℃~80℃

-20℃~80℃

-20℃~80℃

ambient temperature

-30℃~60℃

-30℃~60℃

-30℃~60℃


6、 Product selection

model

Instructions

LWQ

—□

/□

/□

/□

instrument
type

N

Sensor type:+12V or 24V power supply, output three wire pulse signal

A

Transmitter type:+24V power supply, output two-wire 4-20mA

B

Intelligent type: Powered by lithium batteries, no signal output displayed on site

C

Intelligent type:+24V power supply, on-site display and output of two-wire 4-20mA

D

Fully intelligent: temperature and pressure compensation integrated, on-site display and remote signal transmission

Nominal diameter and
measurement range

25

DN 25mm

40

DN 40 mm

50

DN 50 mm

65

DN 65 mm

80

DN 80 mm

100

DN 100 mm

125

DN 125 mm

150

DN 150 mm

200

DN 200 mm

250

DN 250 mm

300

DN 300 mm

measurement range

W(x)

To expand the range, please refer to Table 2 on page Px for selection

S(x)

Standard range, please refer to Table 2 on page Px for selection

Body material

S

stainless steel

L

aluminum alloy

Material of the movement

S

Anti corrosion ABS

L

aluminum alloy

N

No special structure

A

Oxygen specific

B

Dedicated for compressed air

Selection guide: When selecting, manufacturers should reasonably choose the model and specifications of flow meters based on the nominal pressure of the pipeline, medium, maximum pressure, medium temperature, medium composition (such as natural gas, various gases), flow range, and signal output requirements. To make the use of the flowmeter more accurate, the flow range of the flowmeter should be within the Qmax range of (20% to 80%), which is more appropriate.