E-mail
wxbrck@ 163.com
-
Phone
13812024099
-
Address
No. 35 Xigang East Road, Xishan District, Wuxi City
Jiangsu Borui Measurement and Control Technology Co., Ltd
wxbrck@ 163.com
13812024099
No. 35 Xigang East Road, Xishan District, Wuxi City

Table 1: Liquids and Gases (Unit: m)3/h)
|
path (DN) |
Liquid flow range (m3/h) |
Output frequency range (Hz) |
Gas flow range (m3/h) |
Output frequency range (Hz) |
|
15 |
1.2~6.2 |
90~900 |
5~25 |
265~2640 |
|
20 |
1.5~10 |
40~396 |
8~50 |
218~1982 |
|
25 |
1.6~16 |
32~325 |
10~70 |
172~1420 |
|
32 |
2~20 |
20~250 |
15~150 |
130~1350 |
|
40 |
2.5~25 |
13~130 |
22~220 |
115~1147 |
|
50 |
3.5~35 |
9~93 |
36~320 |
96~854 |
|
65 |
6~60 |
8~82 |
50~480 |
61~583 |
|
80 |
10~100 |
6~65 |
70~640 |
45~417 |
|
100 |
15~150 |
5~50 |
130~1100 |
43~367 |
|
125 |
25~250 |
5~47 |
200~1700 |
33~290 |
|
150 |
40~400 |
4~40 |
280~2240 |
27~221 |
|
200 |
80~800 |
3~33 |
580~4960 |
24~207 |
|
250 |
140~1400 |
3~26 |
970~8000 |
20~171 |
|
300 |
200~2000 |
2~22 |
1380~11000 |
17~136 |
|
path (DN) |
L (mm) |
H (mm) |
|
|||||||||
|
10 |
66 |
360 |
||||||||||
|
15 |
66 |
360 |
||||||||||
|
20 |
66 |
360 |
||||||||||
|
25 |
66 |
360 |
||||||||||
|
32 |
66 |
365 |
||||||||||
|
40 |
80 |
370 |
||||||||||
|
50 |
80 |
375 |
||||||||||
|
65 |
93 |
383 |
||||||||||
|
80 |
100 |
390 |
||||||||||
|
100 |
125 |
400 |
||||||||||
|
125 |
145 |
470 |
||||||||||
|
150 |
165 |
500 |
||||||||||
|
200 |
196 |
580 |
||||||||||
|
250 |
235 |
650 |
||||||||||
|
300 |
255 |
700 |
||||||||||
|
5、 Installation diagram |
||||||||||||
|
Precautions |
Legend |
|||||||||||
|
1. Installation of expansion pipe For small diameters and large flow rates, it is necessary to expand the pipe installation and ensure that the front straight pipe section of the flowmeter is ≥ 15D and the rear straight pipe section is ≥ 5D |
|
|||||||||||
|
2. Installation of shrink tubing For large caliber and small flow, it is necessary to install a reduction pipe, while ensuring that the front straight pipe section of the flowmeter is ≥ 15D and the rear straight pipe section is ≥ 5D |
|
|||||||||||
|
3. Installation of bent pipes If the front end of the flowmeter has a 90 ° elbow or T-shaped joint, it is necessary to ensure that the front straight pipe section of the flowmeter is ≥ 15D and the rear straight pipe section is ≥ 5D |
|
|||||||||||
|
4. Installation of two bent pipes on the same plane If there are two 90 ° elbows at the front end of the flowmeter, it is necessary to ensure that the front straight pipe section of the flowmeter is ≥ 20D and the rear straight pipe section is ≥ 5D |
|
|||||||||||
|
5. Installation of two curved pipes in different planes If there are two 90 ° elbows at the front end of the flowmeter, it is necessary to ensure that the front straight pipe section of the flowmeter is ≥ 25D and the rear straight pipe section is ≥ 5D |
|
|||||||||||
|
6. Installation of regulating valve If regulating valves need to be installed before and after the flowmeter, it is necessary to ensure that the front straight pipe section of the flowmeter is ≥ 25D and the rear straight pipe section is ≥ 5D |
|
|||||||||||
|
VI. Product Selection Table |
||||||||||||
|
LUGB |
Flange type vortex flowmeter |
|||||||||||
|
caliber (mm) |
10 |
DN10~DN50 (flange type, clamp type, threaded type, clamp type) |
||||||||||
|
50 |
DN50~DN150 (clamp type, flange type) |
|||||||||||
|
100 |
DN100~DN300 (flange type, clamp type) |
|||||||||||
|
300 |
DN300 and above are plug-in type |
|||||||||||
|
Installation method |
B |
clamp-on |
||||||||||
|
L |
Flange connection type |
|||||||||||
|
C |
plug-in |
|||||||||||
|
compensation method |
none |
No compensation |
||||||||||
|
BC |
Temperature and pressure compensation |
|||||||||||
|
W |
Single temperature compensation |
|||||||||||
|
Y |
Single pressure compensation |
|||||||||||
|
measuring medium |
Y |
liquid |
||||||||||
|
Q |
gas |
|||||||||||
|
Z |
steam |
|||||||||||
|
temperature range |
T1 |
Room temperature type (below 120 ℃) |
||||||||||
|
T2 |
High temperature type (below 250 ℃) |
|||||||||||
|
pressure rating |
P1 |
Normal pressure~1.6MPa |
||||||||||
|
P2 |
2.5MPa |
|||||||||||
|
P3 |
4.0MPa |
|||||||||||
|
body material |
A |
carbon steel |
||||||||||
|
B |
304 stainless steel |
|||||||||||
|
C |
316 stainless steel |
|||||||||||
|
power supply method |
D |
Two wire system DC24V 4-20mA |
||||||||||
|
H |
Two wire DC24V 4-20mA+HART protocol |
|||||||||||
|
C |
battery-powered |
|||||||||||
|
Additional options |
R |
RS485 MODBUS communication protocol |
||||||||||
|
M |
pulse output |
|||||||||||
|
B |
Explosion proof (ExII CT6) |
|||||||||||