E-mail
wxbrck@ 163.com
-
Phone
13812024099
-
Address
No. 35 Xigang East Road, Xishan District, Wuxi City
Jiangsu Borui Measurement and Control Technology Co., Ltd
wxbrck@ 163.com
13812024099
No. 35 Xigang East Road, Xishan District, Wuxi City

| Lining material | Main performance | Maximum medium temperature | Scope of Application | |
| Integrated type | Separated type | |||
| Polytetrafluoroethylene(F4) | It is a chemically stable plastic that can withstand boiling hydrochloric acid, sulfuric acid, nitric acid, and aqua regia, as well as concentrated alkali and various organic solvents. Not resistant to corrosion from chlorine trifluoride, high-temperature chlorine trifluoride, high flow rate liquid fluorine, liquid oxygen, and auto oxygen. | 70℃ |
100℃ 250℃ (Special order required) |
1. Strong corrosive media such as concentrated acid and alkali. 2. Sanitary media. |
| Perfluoroethylene propylene(F46) | 同F4, Wear resistance and negative pressure resistance are higher than F4. | Ditto. | ||
| Polyfluoroethylene(Fs) | The upper limit of applicable temperature is lower than that of polytetrafluoroethylene, but the cost is also lower. | 80℃ | ||
| Polychloroprene rubber |
1. Has excellent elasticity, high tensile strength, and good wear resistance. 2. Resistant to corrosion in general low concentration acid, alkali, and salt media, but not resistant to corrosion in oxidizing media. |
80℃ 120℃ (Special order required) |
Water, sewage, and weakly abrasive slurry. | |
| polyurethane rubber | 1Extremely strong wear resistance. | 80℃ | Neutral strong abrasion slurry, coal slurry, mud | |
| 2Poor corrosion resistance. | ||||
| electrode material | Corrosion resistance and wear resistance |
| stainless steel0Crl8Nil2M02Ti | Used for weakly corrosive media such as industrial water, domestic water, sewage, etc., suitable for industrial sectors such as petroleum, chemical, steel, as well as municipal and environmental protection fields. |
| HastelloyB | It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as to non chlorinated acids, bases, and non oxidizing salt solutions such as sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids. |
| HastelloyC | Can withstand corrosion from non oxidizing acids such as nitric acid, mixed acids, or mixed media of chromic acid and sulfuric acid, as well as oxidative salts such as:Corrosion under Fc+, Cu+or with other oxidants, such as corrosion in hypochlorite solutions above room temperature or seawater |
| Titanium | Capable of withstanding seawater, various chlorides and hypochlorites, and oxidizing acidsCorrosion caused by (including fuming sulfuric acid), organic acids, and alkalis. Not resistant to the corrosion of relatively pure reducing acids (such as sulfuric acid, hydrochloric acid), but if the acid contains oxidants (such as nitric acid, Fc+, Cu+), the corrosion is greatly reduced. |
| Tantalum | It has excellent corrosion resistance and is very similar to glass. Except for hydrofluoric acid, fuming sulfuric acid, and alkali, it can almost withstandCorrosion of a chemical medium (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 50 ℃). Dig in alkali; Corrosion resistance. |
| Platinum/titanium alloy | Can withstand almost all chemical media, but not suitable for aqua regia and ammonium salts. |
| Stainless steel coated with tungsten carbide | Used for non corrosive and highly abrasive media. |
| Note: Due to the wide variety of media and the complex factors such as temperature, concentration, and flow rate that affect their corrosiveness, this table is for reference only. Users should make their own choices based on the actual situation, and if necessary, conduct corrosion resistance tests on the selected materials, such as hanging plate tests. | |
| calibermm | Flow range m ³/h | calibermm | Flow range m ³/h |
| DN10 | 0.16~2.5 | DN400 | 250~4000 |
| DN15 | 0.4~6 | DN500 | 400~6000 |
| DN20 | 0.6~12 | DN600 | 600~10000 |
| DN25 | 1.0~16 | DN700 | 800~12000 |
| DN32 | 1.6~25 | DN800 | 1000~16000 |
| DN40 | 2.5~40 | DN900 | 1200~20000 |
| DN50 | 4.0~60 | DN1000 | 1600~25000 |
| DN65 | 6.0~120 | DN1200 | 2500~30000 |
| DN80 | 10~160 | DN1400 | 3000~50000 |
| DN100 | 16~250 | DN1600 | 3000~60000 |
| DN125 | 25~400 | DN1800 | 5000~60000 |
| DN150 | 40~600 | DN2000 | 6000~100000 |
| DN200 | 60~1000 | DN2200 | 1367.78~136778.4 |
| DN250 | 100~1600 | DN2400 | 1627.78~162777.6 |
| DN300 | 160~2500 | DN2600 | 1910.38~191037.6 |
| DN350 | 200~3000 | DN2800 | 2306.56 ~ 236062.8 |