NegotiableUpdate on 11/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

1、 Pulse turbine flowmeter product overview Pulse turbine flowmeter is a new type of intelligent instrument developed using advanced ultra-low power single-chip microcomputer technology, which integrates turbine flow sensor and display integration. It has a compact mechanism, intuitive and clear readings, high reliability ..

Product Details

1、 Overview of Pulse Turbine Flow Meter Products
Pulse turbine flowmeter is a new intelligent instrument developed using advanced ultra-low power single-chip microcomputer technology, which integrates turbine flow sensor and display integration. It has obvious advantages such as compact structure, intuitive and clear readings, high reliability, no external power interference, lightning resistance, and low cost.
2、 Product performance of pulse turbine flowmeter
1. High precision, generally up to ± 1% R, ± 0.5% R, and high-precision models up to ± 0.2% R;
2. Output pulse frequency signal, suitable for total measurement and computer connection, no zero drift, strong anti-interference ability;
3. Can obtain high frequency signals (3-4kHz) with strong signal resolution;
4. Wide range, with a medium to large caliber of up to 1:20 and a small caliber of 1:10;
5. Compact and lightweight structure, easy installation and maintenance, and high circulation capacity;
6. Suitable for high voltage measurement, there is no need to open holes on the instrument body, making it easy to make high voltage instruments;
7. Can be made into an insertion type, suitable for measuring large diameters, with low pressure loss, low price, can be removed without interruption, and easy installation and maintenance.
8. Good repeatability: Short term repeatability can reach 0.05%~0.2%. It is precisely because of its good repeatability that high accuracy can be achieved through regular calibration or online calibration. It is the preferred flowmeter for various manufacturers, as shown in Figure 1.


Figure 1

3、 Technical performance of pulse turbine flowmeter: Table 1

Instrument caliber and connection method 4. 6, 10, 15, 20, 25, 32, 40 are connected by threads
(15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 are connected by flanges
accuracy class ±0.5%R
turndown ratio 1:10; 1:15; 1:20
Instrument material 304 stainless steel, 316 (L) stainless steel, etc
Temperature of the tested medium (℃) -20~+120℃
environmental conditions Temperature -10~+55 ℃, relative humidity 5%~90%, atmospheric pressure 86~106Kpa
output signal 4-20mADC current signal (LWGY - □ C type)
power supply LWGY - □ B type: Comes with lithium battery power supply (can be used continuously for 3 years); LWGY - □ C type:+24VDC
Signal transmission line 2 × 0.3 (two-wire system)
transmission distance ≤1000m
Signal line interface Internal thread M20 × 1.5 (LWGY - □ C type)
Explosion-proof rating ExdIIBT6
Protection level IP65


4、 Measurement range and working pressure of pulse turbine flowmeter: Table 2

Instrument diameter (mm) Normal flow range (m3/h) Expand flow range (m3/h) Conventional withstand pressure (MPa) Specially designed pressure resistance level (MPa) (flange connection method)
DN 4 0.04~0.25 0.04~0.4 6.3 12. 16, 25
DN 6 0.1~0.6 0.06~0.6 6.3 12. 16, 25
DN 10 0.2~1.2 0.15~1.5 6.3 12. 16, 25
DN 15 0.6~6 0.4~8 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 20 0.8~8 0.45~9 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 25 1~10 0.5~10 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 32 1.5~15 0.8~15 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 40 2~20 1~20 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 50 4~40 2~40 2.5 4.0, 6.3, 12, 16, 25
DN 65 7~70 4~70 2.5 4.0, 6.3, 12, 16, 25
DN 80 10~100 5~100 2.5 4.0, 6.3, 12, 16, 25
DN 100 20~200 10~200 2.5 4.0, 6.3, 12, 16, 25
DN 125 25~250 13~250 1.6 2.5, 4.0
DN 150 30~300 15~300 1.6 2.5, 4.0
DN 200 80~800 40~800 1.6 2.5, 4.0

5、 Pulse turbine flowmeter nominal diameter: Table 3
model Nominal diameter (mm) L(mm) H(mm) G Lˊ(mm) D(mm) d(mm) number of holes
LWGY-4 4 275 145 G1/2 215
LWGY-6 6 275 145 G1/2 215
LWGY-10 10 455 165 G1/2 350
LWGY-15 15 75 173 G1 F65 F14 4
LWGY-25 LWGY-32 25 32 100 140 180 G5/4 G2 F85 F100 F14 4
LWGY-40 40 140 178 G2 F14 4
LWGY-50 50 150 252 F125 F18 4
LWGY-80 80 200 287 F160 F18 8
LWGY-100 100 220 322 F180 F18 8
LWGY-150 150 300 367 F250 F25 8
LWGY-200 200 360 415 F295 F23 12

6、 Product selection table for pulse turbine flowmeter: Table 4

Model number Explanation
LWGY /□ /□ /□ /□ /□ /□
Nominal diameter 4 4mm, The standard range is 0.04-0.25m3/h, and the wide range is 0.04-0.4m3/h
6 6mm, The standard range is 0.1-0.6m3/h, and the width measuring wheel is 0.06-0.6m3/h
10 10mm, The standard range is 0.2-1.2m3/h, and the wide range is 0.15-1.5m3/h
15 15mm, The standard range is 0.6-6m3/h, and the wide range is 0.4-8m3/h
20 20mm, The standard range is 0.8-8m3/h, and the wide range is 0.4-8m3/h
25 25mm, The standard range is 1-10m3/h, and the wide range is 0.5-10m3/h
32 32mm, The standard range is 1.5-15m3/h, and the wide range is 0.8-15m3/h
40 40mm, The standard range is 2-20m3/h, and the wide range is 1-20m3/h
50 50mm, The standard range is 4-40m3/h, and the wide range is 2-40m3/h
65 65mm, The standard range is 7-70m3/h, and the wide range is 4-70m3/h
80 80mm, The standard range is 10-100m3/h, and the wide range is 5-100m3/h
100 100mm, The standard range is 20-200m3/h, and the wide range is 10-200m3/h
125 125mm, The standard range is 25-250m3/h, and the wide range is 13-250m3/h
150 150mm, The standard range is 30-300m3/h, and the wide range is 15-300m3/h
200 200mm, The standard range is 80-800m3/h, and the wide range is 40-800m3/h
type B Battery powered on-site display type
C On site display: 4-20mA two-wire current output
C1 On site display/RS485 communication protocol
C2 On site display/ART communication protocol
accuracy class 05 Accuracy level 0.5
10 Accuracy class 1.0
Turbine type W Wide range turbine
S Standard turbine
material S 304 stainless steel
L 316 (L) stainless steel
explosion-proof E Explosion proof type (explosion-proof grade: Exd Ⅱ BT6)
pressure rating N Conventional (refer to Table 2)
H(x) High voltage (refer to Table 2)

7、 Technical parameters of pulse turbine flowmeter: Table 5
model Pulse 4-20mA turbine flowmeter
Instrument model LWGY-N LWGY-A LWGY-N LWGY - A LWGY-B LWGY-C
signal output pulse 4-20mA pulse Or 4-20mA none 4-20mA/pulse
power supply +24VDC±15% +24VDC±15% 24VDC±15% 24VDC±15% lithium battery 24VDC±15%
accuracy class 1.0~0.5 level 1.0~0.5 level 1.0~0.5 level
measurement range Standard range Standard range Standard range or extended range
communication interface none none Optional RS485
Instrument material Stainless steel, 316 Stainless steel, 316 Stainless steel, 316
Explosion-proof rating none ExdIIBT6 or ExiaICIT4 ExdIIBT6 or ExiaICIT4
Protection level IP60 IP65 IP65
Total power consumption <1W <1W <1W
Instrument diameter DN4~DN250 DN4~DN250 DN4~DN250
medium temperature -20℃~180℃ -20℃~180℃ -20℃~180℃
ambient temperature -30℃~60℃ -30℃~60℃ -30℃~60℃

8、 Installation techniques for pulse turbine flowmeter
1. When installing a turbine flowmeter, attention should be paid to staying away from external electric and magnetic fields, and effective shielding measures should be taken if necessary to avoid external interference. Turbine flow meters can be installed horizontally or vertically, and the fluid direction must be upward when installed vertically. The liquid should fill the pipeline without any bubbles. During installation, the direction of liquid flow should be consistent with the direction indicated by the arrow on the sensor housing. During installation, the pipeline must be filled with fluid to ensure accurate measurement.
2. The upstream end of the flowmeter should have a straight pipe section at least 10 times the nominal diameter length, and the downstream end should have a straight pipe section at least 5 times the nominal diameter. The inner wall should be smooth and clean, without defects such as dents, scale, and peeling.
9、 Price of pulse turbine flowmeter products
The price of pulse turbine flowmeter is related to the medium, pressure, installation method, and diameter. The final price should be based on the on-site working conditions. Platinum Rui will provide you with the most favorable price and quality service!