Platinum Measurement and Control specializes in producing clamp type electromagnetic flow meters. Welcome to consult with clamp type electromagnetic flow meter manufacturers. 1、 Overview of clamp type electromagnetic flowmeter products Platinum Rui clamp type sanitary electromagnetic flowmeter measures flow according to Faraday's law of electromagnetic induction. ...

Product Details

Platinum Measurement and Control specializes in producing clamp type electromagnetic flow meters. Welcome to consult with clamp type electromagnetic flow meter manufacturers.

1Clamp type electromagnetic flowmeterProduct Overview
Platinum Rui clamp type sanitary electromagnetic flowmeter is used for flow measurement based on Faraday's law of electromagnetic induction. The advantages of electromagnetic flowmeter are minimal pressure loss and a wide range of measurable flow rates. The ratio of maximum flow rate to minimum flow rate is generally above 20:1, suitable for a wide range of industrial pipe diameters. The output signal is linear with the measured flow rate, with high accuracy, and can measure liquids with conductivity ≥ 5 μ s/cm.Clamp type electromagnetic flowmeter has the advantages of easy installation and cleaning, and is commonly used in food production, pharmaceutical industry pharmaceutical measurement, and water purification monitoringAs shown in Figure 1.


Figure 1

2、 Characteristics of clamp type electromagnetic flowmeter products
1. Extremely strong corrosion resistance, capable of testing almost any conductive liquid
2. Strong anti-interference ability, almost unaffected by external interference
3. Measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity
4. Measure the unobstructed flow components inside the tube without pressure loss, and have low requirements for straight pipe sections.
5. There are no movable parts or flow blocking components in the pipeline, and there is almost no negative pressure loss measured
6. Equipped with self checking and self diagnostic functions
7. On site, the range can be modified online according to the actual needs of the user
3、 Selection Table for Lining of Clamp Electromagnetic Flow Meter
Lining material Main performance Maximum medium temperature Scope of Application
Integrated type Separated type
Polytetrafluoroethylene(F4) It is a chemically stable plastic that can withstand boiling hydrochloric acid, sulfuric acid, nitric acid, and aqua regia, as well as concentrated alkali and various organic solvents. Not resistant to corrosion from chlorine trifluoride, high-temperature chlorine trifluoride, high flow rate liquid fluorine, liquid oxygen, and auto oxygen. 70℃ 100℃ 250℃
(Special order required)
1. Strong corrosive media such as concentrated acid and alkali.
2. Sanitary media.
Perfluoroethylene propylene(F46) F4, Wear resistance and negative pressure resistance are higher than F4. Ditto.
Polyfluoroethylene(Fs) The upper limit of applicable temperature is lower than that of polytetrafluoroethylene, but the cost is also lower. 80℃
Polychloroprene rubber 1. Has excellent elasticity, high tensile strength, and good wear resistance.
2. Resistant to corrosion in general low concentration acid, alkali, and salt media, but not resistant to corrosion in oxidizing media.
80℃ 120℃
(Special order required)
Water, sewage, and weakly abrasive slurry.
polyurethane rubber 1Extremely strong wear resistance. 80℃ Neutral strong abrasion slurry, coal slurry, mud
2Poor corrosion resistance.

4、 Electrode selection table for clamp type electromagnetic flowmeter
electrode material Corrosion resistance and wear resistance
stainless steel0Crl8Nil2M02Ti Used for weakly corrosive media such as industrial water, domestic water, sewage, etc., suitable for industrial sectors such as petroleum, chemical, steel, as well as municipal and environmental protection fields.
HastelloyB It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as to non chlorinated acids, bases, and non oxidizing salt solutions such as sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids.
HastelloyC Can withstand corrosion from non oxidizing acids such as nitric acid, mixed acids, or mixed media of chromic acid and sulfuric acid, as well as oxidative salts such as:Corrosion under Fc+, Cu+or with other oxidants, such as corrosion in hypochlorite solutions above room temperature or seawater
Titanium Capable of withstanding seawater, various chlorides and hypochlorites, and oxidizing acidsCorrosion caused by (including fuming sulfuric acid), organic acids, and alkalis. Not resistant to the corrosion of relatively pure reducing acids (such as sulfuric acid, hydrochloric acid), but if the acid contains oxidants (such as nitric acid, Fc+, Cu+), the corrosion is greatly reduced.
Tantalum It has excellent corrosion resistance and is very similar to glass. Except for hydrofluoric acid, fuming sulfuric acid, and alkali, it can almost withstandCorrosion of a chemical medium (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 50 ℃). Dig in alkali; Corrosion resistance.
Platinum/titanium alloy Can withstand almost all chemical media, but not suitable for aqua regia and ammonium salts.
Stainless steel coated with tungsten carbide Used for non corrosive and highly abrasive media.
Note: Due to the wide variety of media and the complex factors such as temperature, concentration, and flow rate that affect their corrosiveness, this table is for reference only. Users should make their own choices based on the actual situation, and if necessary, conduct corrosion resistance tests on the selected materials, such as hanging plate tests.

5、 Comparison Table of Flow Diameter of Clamp Electromagnetic Flow Meter
calibermm Flow range m ³/h calibermm Flow range m ³/h
DN10 0.16~2.5 DN400 250~4000
DN15 0.4~6 DN500 400~6000
DN20 0.6~12 DN600 600~10000
DN25 1.0~16 DN700 800~12000
DN32 1.6~25 DN800 1000~16000
DN40 2.5~40 DN900 1200~20000
DN50 4.0~60 DN1000 1600~25000
DN65 6.0~120 DN1200 2500~30000
DN80 10~160 DN1400 3000~50000
DN100 16~250 DN1600 3000~60000
DN125 25~400 DN1800 5000~60000
DN150 40~600 DN2000 6000~100000
DN200 60~1000 DN2200 1367.78~136778.4
DN250 100~1600 DN2400 1627.78~162777.6
DN300 160~2500 DN2600 1910.38~191037.6
DN350 200~3000 DN2800 2306.56 ~ 236062.8

6、 Comparison Table for Selection of Clamp Electromagnetic Flowmeters
model caliber
LDE 10~2600
code name Installation type
Y integrated
F split-type
code name transformer model
ZA rotundity
ZB Square (only applicable to split type)
code name Power supply form
AC (AC) 220V AC 50Hz (90~245V AC 50Hz)
DC (DC) 24V DC (20-36V DC)
LD Lithium battery power supply (without signal output)
code name
I
f
Rs
H
C
medium temperature
≤65℃
≤120℃
≤ 180 ℃ (only applicable to split type)
code name Lining material
NE Chloroprene rubber (≤ 65 ℃)
PVC Polyvinyl chloride (≤ 70 ℃)
PU Polyurethane wear-resistant (≤ 80 ℃)
PTFE Polytetrafluoroethylene (≤ 180 ℃)
code name electrode material
316L stainless steel
HC Hastelloy C
Ti Titanium
Ta Tantalum
Pt platinum
Reminder: Essential for flowmeter selection, medium, caliber (flow range), electrode material, lining material, installation method
7、 Price
The price of clamp type electromagnetic flowmeter manufacturers is related to other parameters, such as caliber, pressure, and installation method. The larger the caliber, the higher the pressure, and the more expensive the price. The final price should be based on the actual parameters, and Platinum Rui will provide you with the most favorable price and quality service!