E-mail
wxbrck@ 163.com
-
Phone
13812024099
-
Address
No. 35 Xigang East Road, Xishan District, Wuxi City
Jiangsu Borui Measurement and Control Technology Co., Ltd
wxbrck@ 163.com
13812024099
No. 35 Xigang East Road, Xishan District, Wuxi City
XMD-16AMain performance characteristics
· The accuracy is ± 0.5% FS ± ldig.
· Made with dedicated chips, it has a high degree of intelligence.
· 16 channels can be freely selected, and manual/automatic inspection can be switched.
· Each channel can have its upper and lower limits set arbitrarily, and there are 4 reminder contact outputs.
· Product features: small size, reliable installation structure.
● Input format
thermocouple
B:0~1800℃ S:0~1600℃
K:0~1300℃E:0~800℃
T:0~400℃J:0~1000℃
EA::0~800℃N:0~1300℃
thermal resistor
Ptl00:-199.9~6000C
Cul00:-50~150℃
Cu50:-50~150℃
BA1:-199.9~600℃
BA2:-199.9~600℃
DC voltage
0~20mV,0~100mV,0~5V,1~5V
Self flowing current
0~20mV, 0~100mV,0~5V,1~5V
Others:
Remote transmission pressure gauge 0-400 Ω, frequency 0.01-10000Hz
Note: The measurement range of DC current, DC voltage, and remote pressure gauge can be programmed freely.
● output format
call the police
This instrument has four sets of contact outputs that can work in the following three modes
· Unified reminder: At 16:00, the upper and lower limit reminder points are uniformly set with two relay outputs.
· 1The 16 reminder points (upper and lower limits) can be set with different values, and as long as one of them exceeds the limit (upper or lower limit) and the two relays have corresponding outputs.
· 4Road inspection reminder and L2 inspection display: The first four channels can each use a separate set of relays for reminder or control, while the remaining 12 channels are used for patrol inspection.
Note: One or two modes can add two real-time reminders, which users can use as needed.
The relay contact capacity is 3A, 200V AC.
● Power supply
220V±10%AC 50Hz±5%
□ Model representation
X M D – 1 6□ / □ □ □
|
X |
M |
D |
Specifications |
content |
||||||
|
- |
||||||||||
|
16 |
Number of inspection routes (1-16 routes) |
|||||||||
|
A |
16080mm horizontal |
|||||||||
|
H |
80160mm vertical type |
|||||||||
|
F |
96×96mm |
|||||||||
|
Overall dimensions |
/ |
|||||||||
|
0 |
none |
|||||||||
|
1 |
Unified alarm for upper and lower limits, output of upper and lower limit relays J1 and 2 |
|||||||||
|
2 |
Independent upper and lower limit alarms, upper and lower limit relays J1 and 2 output |
|||||||||
|
3 |
*4Road inspection alarm J1-J4 relay output, 12 road inspection display |
|||||||||
|
alarm method |
1 |
thermocouple |
||||||||
|
2 |
thermal resistor |
|||||||||
|
3 |
other |
|||||||||
|
5 |
current signal |
|||||||||
|
7 |
voltages |
|||||||||
|
input format |
DesIgn Serial Number |
|||||||||
|
X |
M |
D |
- |
16 |
□ |
/ |
□ |
□ |
□ |
|
Note: Strike*Number onlyA、HDimensions of the shape.