E-mail
wxbrck@ 163.com
-
Phone
13812024099
-
Address
No. 35 Xigang East Road, Xishan District, Wuxi City
Jiangsu Borui Measurement and Control Technology Co., Ltd
wxbrck@ 163.com
13812024099
No. 35 Xigang East Road, Xishan District, Wuxi City
Main performance characteristics
· Adopting advanced SMT surface mount technology
· Adopting advanced switching power supply to make the instrument appear more lightweight
· Having full input function not only enables the instrument to have multiple uses, but also increases its flexibility.
· It has power failure protection function.
· It has power failure protection function.
· The accuracy is 5% FS ± 1ding
· Two sets of circuit breakers can be flexibly used for output, which can be used for alarm and adjustment.
· The range can be freely shifted during linear input.
· Has a very high cost performance ratio.
· Clear and intuitive presentation
· Reliable and practical instrument installation structure.
· The resolution is 14 bits
· Equipped with sensor error correction function.
● Input format
thermocouple
B:0~1800℃ S:0~1600℃
K:0~1300℃ E:0~800℃
T:0~300℃ J:0~800℃
Wu-Re3-25 0~2000℃
Thermal resistance:
Pt100:-100~200℃
-200~600℃
Cu50:0~150℃
linear input
mVInput: 0-100mV.DC; 0~50mV.DC; 0~100mV.DC;
Voltage input: 0-5V. DC; 1~5V.DC;
Current input: 0-100mA.DC; 4~20mA.DC;
Resistance remote transmission pressure signal: 0~400 Ω
Radiation temperature sensor:
WFT-202(F1Quartz glass) 400-1200 ℃
WFT-202(F2, K9Glass) 700-2000 ℃
● Output format
The output of the two sets of relay contacts can be arbitrarily composed in the following ways:
1. Upper limit alarm
2Lower limit alarm (two position control)
3Upper and lower limit alarms (three position control)
4Upper and upper limit alarms
5Lower and lower limit alarms
The insensitive area of each contact is adjustable from 0 to 9999
The capacity of each contact is 3A, 220V AC, with no inductive load.
●power supply
Transformer power supply:220V±10% 50Hz~60 Hz
Switching power supply:86V~264VAC 50Hz~60 Hz
Power supply for transmitter:24V、 30mA.DC
□ Model representation
X□ M - □ □ - D
|
X |
Specifications |
content |
||||||||
|
Z |
Single Display |
|||||||||
|
T |
With adjustment |
|||||||||
|
Instrument form |
M |
|||||||||
|
A |
16080 (mm) vertical type A (H) |
|||||||||
|
D |
96×96(mm) |
|||||||||
|
E |
72×72(mm) |
|||||||||
|
F |
4896 (mm) vertical is F (H) |
|||||||||
|
Overall dimensions |
- |
|||||||||
|
1 |
||||||||||
|
0 |
Upper and upper limit alarms |
|||||||||
|
1 |
Upper and lower limit alarms |
|||||||||
|
2 |
Lower and upper limit alarms |
|||||||||
|
3 |
Lower and lower limit alarms |
|||||||||
|
Adjustment mode/alarm mode |
0 |
Full input |
||||||||
|
1 |
thermocouple |
|||||||||
|
2 |
thermal resistor |
|||||||||
|
4 |
Remote pressure gauge |
|||||||||
|
5 |
linear input |
|||||||||
|
6 |
total radiation pyrometer |
|||||||||
|
- |
||||||||||
|
Additional features |
Equipped with 24V transmitter power supply |
|||||||||
|
X |
□ |
M |
□ |
- |
1 |
□ |
□ |
- |
D |
|
Note: Users should specify the specific model when placing an order, and set it according to that model when leaving the factory. If the specific model and specifications are not specified, set it according to the factory values in the manual.