Welcome Customer !

Membership

Help

Jiangsu Borui Measurement and Control Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Jiangsu Borui Measurement and Control Technology Co., Ltd

  • E-mail

    wxbrck@ 163.com

  • Phone

    13812024099

  • Address

    No. 35 Xigang East Road, Xishan District, Wuxi City

Contact Now

Platinum Rui Turbine Flow Meter - Wuxi Platinum Rui Measurement and Control

NegotiableUpdate on 11/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Turbine flowmeter can measure gases and liquids, with advantages such as high sensitivity and precise measurement. 1、 Product Overview: The LWGY turbine flowmeter is an optimized design that incorporates advanced flow meter technologies from both domestic and international sources. It features a simple structure, lightweight design, high precision, and good reproducibility ..

Product Details

Turbine flowmeter can measure gases and liquids, with advantages such as high sensitivity and precise measurement.

1、 Product Overview
The LWGY turbine flowmeter has been optimized and designed by drawing on advanced flow meter technologies from both domestic and international sources,The new generation turbine flowmeter with the characteristics of simple structure, lightweight, high accuracy, good reproducibility, sensitive response, and easy installation, maintenance, and use is shown in Figure 1Widely used for measuring liquids in closed pipelines that do not corrode stainless steel 1Cr18Ni9Ti, 2Cr13, corundum AI2O3, and hard alloys, and have no impurities such as fibers or particles. The liquid has a kinematic viscosity of less than 5 × 10-6m2/s at working temperature. For liquids with a kinematic viscosity greater than 5 × 10-6m2/s, the flowmeter can be calibrated for real liquid before use If paired with display instruments with special functions, it can also perform quantitative control, over limit alarm, etc., making it an ideal instrument for flow measurement and energy conservation

Figure 1
2、 Performance characteristics
1. High precision, generally up to ± 1% R, ± 0.5% R, and high-precision models up to ± 0.2% R;
2. Output pulse frequency signal, suitable for total measurement and computer connection, no zero drift, strong anti-interference ability;
3. Can obtain high frequency signals (3-4kHz) with strong signal resolution;
4. Wide range, with a medium to large caliber of up to 1:20 and a small caliber of 1:10;
5. Compact and lightweight structure, easy installation and maintenance, and high circulation capacity;
6. Suitable for high voltage measurement, there is no need to open holes on the instrument body, making it easy to make high voltage instruments;
7. Can be made into an insertion type, suitable for measuring large diameters, with low pressure loss, low price, can be removed without interruption, and easy installation and maintenance.
8. Good repeatability, short-term repeatability can reach 0.05%~0.2%. It is precisely because of its good repeatability that frequent calibration or online calibration can achieve extremely high accuracy, making it a preferred flowmeter for various manufacturers

3、 Technical performance: Table 1

Instrument caliber and connection method 4. 6, 10, 15, 20, 25, 32, 40 are connected by threads
(15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 are connected by flanges
accuracy class ±0.5%R
turndown ratio 1:10; 1:15; 1:20
Instrument material 304 stainless steel, 316 (L) stainless steel, etc
Temperature of the tested medium (℃) -20~+120℃
environmental conditions Temperature -10~+55 ℃, relative humidity 5%~90%, atmospheric pressure 86~106Kpa
output signal 4-20mADC current signal (LWGY - □ C type)
power supply LWGY - □ B type: Comes with lithium battery power supply (can be used continuously for 3 years); LWGY - □ C type:+24VDC
Signal transmission line 2 × 0.3 (two-wire system)
transmission distance ≤1000m
Signal line interface Internal thread M20 × 1.5 (LWGY - □ C type)
Explosion-proof rating ExdIIBT6
Protection level IP65


4、 Measurement range and working pressure: Table 2

Instrument diameter (mm) Normal flow range (m3/h) Expand flow range (m3/h) Conventional withstand pressure (MPa) Specially designed pressure resistance level (MPa) (flange connection method)
DN 4 0.04~0.25 0.04~0.4 6.3 12. 16, 25
DN 6 0.1~0.6 0.06~0.6 6.3 12. 16, 25
DN 10 0.2~1.2 0.15~1.5 6.3 12. 16, 25
DN 15 0.6~6 0.4~8 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 20 0.8~8 0.45~9 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 25 1~10 0.5~10 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 32 1.5~15 0.8~15 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 40 2~20 1~20 6.3, 2.5 (flange) 4.0, 6.3, 12, 16, 25
DN 50 4~40 2~40 2.5 4.0, 6.3, 12, 16, 25
DN 65 7~70 4~70 2.5 4.0, 6.3, 12, 16, 25
DN 80 10~100 5~100 2.5 4.0, 6.3, 12, 16, 25
DN 100 20~200 10~200 2.5 4.0, 6.3, 12, 16, 25
DN 125 25~250 13~250 1.6 2.5, 4.0
DN 150 30~300 15~300 1.6 2.5, 4.0
DN 200 80~800 40~800 1.6 2.5, 4.0

5、 Nominal diameter: Table 3
model Nominal diameter (mm) L(mm) H(mm) G Lˊ(mm) D(mm) d(mm) number of holes
LWGY-4 4 275 145 G1/2 215
LWGY-6 6 275 145 G1/2 215
LWGY-10 10 455 165 G1/2 350
LWGY-15 15 75 173 G1 F65 F14 4
LWGY-25 LWGY-32 25 32 100 140 180 G5/4 G2 F85 F100 F14 4
LWGY-40 40 140 178 G2 F14 4
LWGY-50 50 150 252 F125 F18 4
LWGY-80 80 200 287 F160 F18 8
LWGY-100 100 220 322 F180 F18 8
LWGY-150 150 300 367 F250 F25 8
LWGY-200 200 360 415 F295 F23 12

6、 Product selection table: Table 4

Model number Explanation
LWGY /□ /□ /□ /□ /□ /□
Nominal diameter 4 4mm, The standard range is 0.04-0.25m3/h, and the wide range is 0.04-0.4m3/h
6 6mm, The standard range is 0.1-0.6m3/h, and the width measuring wheel is 0.06-0.6m3/h
10 10mm, The standard range is 0.2-1.2m3/h, and the wide range is 0.15-1.5m3/h
15 15mm, The standard range is 0.6-6m3/h, and the wide range is 0.4-8m3/h
20 20mm, The standard range is 0.8-8m3/h, and the wide range is 0.4-8m3/h
25 25mm, The standard range is 1-10m3/h, and the wide range is 0.5-10m3/h
32 32mm, The standard range is 1.5-15m3/h, and the wide range is 0.8-15m3/h
40 40mm, The standard range is 2-20m3/h, and the wide range is 1-20m3/h
50 50mm, The standard range is 4-40m3/h, and the wide range is 2-40m3/h
65 65mm, The standard range is 7-70m3/h, and the wide range is 4-70m3/h
80 80mm, The standard range is 10-100m3/h, and the wide range is 5-100m3/h
100 100mm, The standard range is 20-200m3/h, and the wide range is 10-200m3/h
125 125mm, The standard range is 25-250m3/h, and the wide range is 13-250m3/h
150 150mm, The standard range is 30-300m3/h, and the wide range is 15-300m3/h
200 200mm, The standard range is 80-800m3/h, and the wide range is 40-800m3/h
type B Battery powered on-site display type
C On site display: 4-20mA two-wire current output
C1 On site display/RS485 communication protocol
C2 On site display/ART communication protocol
accuracy class 0.5 Accuracy level 0.5
1.0 Accuracy class 1.0
Turbine type W Wide range turbine
S Standard turbine
material S 304 stainless steel
L 316 (L) stainless steel
explosion-proof E Explosion proof type (explosion-proof grade: Exd Ⅱ BT6)
pressure rating N Conventional (refer to Table 2)
H(x) High voltage (refer to Table 2)

7、 Technical parameters: Table 5
Instrument model RL-LWGY-N RL-LWGY-A RL-LWGY-N RL-LWGY- A R-LWGY-B RL-LWGY- C
signal output pulse 4-20mA pulse Or 4-20mA none 4-20mA/pulse
power supply +24VDC±15% +24VDC±15% 24VDC±15% 24VDC±15% lithium battery 24VDC±15%
accuracy class 1.0~0.5 level 1.0~0.5 level 1.0~0.5 level
measurement range Standard range Standard range Standard range or extended range
monitor none none have
communication interface none none Optional RS485
Instrument material stainless steel stainless steel stainless steel
Explosion-proof rating none ExdIIBT6 or ExiaICIT4 ExdIIBT6 or ExiaICIT4
Protection level IP60 IP65 IP65
Total power consumption <1W <1W <1W
Instrument communication DN4~DN250 DN4~DN250 DN4~DN250
medium temperature -20℃~120℃ -20℃~120℃ -20℃~120℃
ambient temperature -30℃~60℃ -30℃~60℃ -30℃~60℃

8、 Installation skills
1. When installing a turbine flowmeter, attention should be paid to staying away from external electric and magnetic fields, and effective shielding measures should be taken if necessary to avoid external interference. Turbine flow meters can be installed horizontally or vertically, and the fluid direction must be upward when installed vertically. The liquid should fill the pipeline without any bubbles. During installation, the direction of liquid flow should be consistent with the direction indicated by the arrow on the sensor housing. During installation, the pipeline must be filled with fluid to ensure accurate measurement.
2. The upstream end of the flowmeter should have a straight pipe section at least 10 times the nominal diameter length, and the downstream end should have a straight pipe section at least 5 times the nominal diameter. The inner wall should be smooth and clean, without defects such as dents, scale, and peeling.

9、 Product price
The price of turbine flowmeter is related to the medium, pressure, installation method, and diameterThe final price should be based on the on-site working conditions, and Platinum Rui will provide you with the most favorable price and quality service!