The LX-3100C portable SF6 new gas purity helium ion detector adopts the principle of helium ionization gas chromatography and is equipped with a high-sensitivity pulse discharge helium ionization detector. It detects the purity of SF6 new gas according to the recommended method of GB/T12022-2014 "Industrial Sulfur Hexafluoride", and analyzes Air, CF4, C2F6, C3F8, H2O, etc. in SF6 new gas with an accuracy of ppb level. The enhanced version can be equipped with a semiconductor tunable laser (TDLAS) module to detect trace amounts of HF.
Technical features:
1. Equipped with high-performance humidity analysis module
In addition to analyzing chromatographic impurities in SF6 new gas, LX-3100C can also perform humidity detection.
2. Highly integrated and modular structural design
The instrument adopts a highly integrated and modular structure design, with carrier gas, standard gas, computer, physical keyboard, touch screen, etc. all concentrated in one chassis, and a built-in 12 inch touch screen for easy operation. The outer box adopts a storm box with a drop resistance height of 1.2 meters, and the modular structure design is simple and easy to maintain.
3. New IC control system design
The brand new IC controlled temperature control system has high temperature control accuracy, superior reliability and anti-interference performance; Equipped with eight completely independent temperature control outputs, it can achieve 20 order programmed heating, improve near room temperature control ability, and have faster heating/cooling speed; The amplification circuit uses logarithmic amplifiers, which have a wider linear range and lower detection limit compared to traditional high impedance amplifiers.
4. SF6 dedicated workstation
The workstation adopts Ethernet communication method, supports simultaneous processing of data from multiple channels of multiple detectors, and supports access to 500 detectors; Can simultaneously read all detection data from the SF6 new gas purity detector; Data encryption measures to ensure data security
5. Multi column box separation system
In response to the complexity of separation, LX-3100C uses a multidimensional system consisting of multiple different chromatographic columns to separate all impurities in the sample.
6. Automatic gas cut-off protection function
When the carrier gas pressure is below the safety threshold, the system will automatically cut off the detector voltage to protect the detector from damage and ensure the safe operation of the instrument.
Technical parameters:
precision |
±0.1℃ |
Instrument dimensions |
625×500×297mm |
|||||
environment |
temperature |
-20~+50℃ |
Working power supply |
AC220V±10% 50Hz |
||||
humidity |
≤ 95% without condensation |
Optional built-in battery |
||||||
Testing components |
Air |
CF4 |
C2F6 |
C3F8 |
H2O |
|||
Detection limit (μ L/L) |
0.05 |
0.05 |
0.05 |
0.05 |
0.1 |
|||