E-mail
lansis@lansis17.com
-
Phone
13636564696
-
Address
Building 6, No. 1699 Huaqing Road, Zhangjiang High tech Park, Qingpu District, Shanghai
Langxi Instrument (Shanghai) Co., Ltd
lansis@lansis17.com
13636564696
Building 6, No. 1699 Huaqing Road, Zhangjiang High tech Park, Qingpu District, Shanghai
| brand | Self operated brand | Instrument type | Portable |
|---|---|---|---|
| Origin category | domestic | Price range | discuss personally |
| Applications | general use | application area | Medical and health care, environmental protection |
LX-3100EAPortable fully automatic transformer oil spectrophotometerUsing headspace degassing technology and the classic three detector process, the content of seven gas components dissolved in insulating oil, including H2, CO, CO2, CH4, C2H4, C2H6, C2H2, etc., is directly analyzed automatically by oil injection. This instrument integrates chromatography system, degassing system, workstation system, nitrogen hydrogen air source and other modules, achieving true portability.
Technical features:
1. Headspace degassing system
LX-3100EAPortable fully automatic transformer oil spectrophotometerAdopting fast headspace degassing technology, the oil is directly fed into the fully automatic and rapid analysis system, eliminating the need for cumbersome operation steps such as oscillation degassing, and avoiding analysis errors caused by human factors.
2. Automatic protection against hydrogen leakage
The hydrogen flame ionization detector has the function of automatic re ignition after extinguishing the flame. If the ignition fails 5 times, the hydrogen flow path will be automatically cut off to ensure safe use.
3. Automatic gas cut-off protection function
Automatic gas cut-off protection function: When the carrier gas pressure is below the safety threshold, the system will automatically cut off the detector voltage to protect the TCD detector from damage and ensure the safe operation of the instrument.
4. Quick shutdown function:
The conversion furnace adopts rapid cooling technology to achieve rapid shutdown.
5. Logarithmic amplification technique:
Adopting advanced digital logarithmic amplification signal acquisition mode, the amplification factor is increased when the content is low, and reduced when the content is high. After signal amplification, the inverse number operation is performed to restore linearity.
6. Highly integrated and modular structural design
The instrument adopts a highly integrated modular structure design, integrating chromatography system, degassing system, workstation system, nitrogen hydrogen air source and other modules. It has a built-in 12 inch touch screen for easy operation, and the outer box adopts a storm box with a drop resistance height of 1.2 meters.
Technical parameters:
precision |
±0.1℃ |
Instrument dimensions |
625×500×366mm |
|||||||
environment |
temperature |
-20~+50℃ |
Working power supply |
AC220V±10% 50Hz |
||||||
humidity |
≤ 95% without condensation |
Optional built-in battery |
||||||||
Testing components |
CH4 |
C2H4 |
C2H6 |
C2H2 |
H2 |
CO |
CO2 |
|||
Detection limit (μ L/L) |
0.05 |
0.05 |
0.05 |
0.05 |
2 |
2 |
5 |
|||