Price of sulfuric acid level gaugeThe prominent feature of concentrated sulfuric acid level gauges is the isolation between the liquid medium and the indicator, making them very safe, reliable, and durable in any situation. Various models of level gauges are equipped with level alarms and control switches, which can achieve upper and lower limit alarm, control, or interlocking of the liquid level or boundary. When equipped with static pressure level transmitters or dry spring resistance level transmitters, the liquid level and boundary signals can be converted into two-wire 4-20mADC standard signals, enabling remote indication, detection, recording, and control. Suitable for liquid level measurement in corrosive media and high operating temperatures, with reliable structure and long service life. It is a good choice for measuring the liquid level of highly corrosive media such as sulfuric acid. Tailored for customers with low temperature and pressure requirements, our PP material level gauge can be used.Price of sulfuric acid level gauge
Users can use remote transmitters according to engineering needs, which can achieve local digital display and output standard remote transmission electrical signals of 4-20mA to meet the needs of recording instruments or industrial process control. It can also be used in conjunction with magnetic control switches or proximity switches to monitor liquid level alarms or control inlet and outlet equipment.
1、 Difference in lining selection for concentrated sulfuric acid level gauge:
The stainless steel lined anti-corrosion magnetic flap level gauge adopts a stainless steel body lined with polypropylene (PP) and polytetrafluoroethylene (PTFE) technology, which has high structural strength and corrosion resistance, and can be applied to acidic liquids such as hydrochloric acid, alkaline liquids, and organic solvents. But it is not suitable for measuring concentrated nitric acid, chlorine containing solvents, aromatic agents, aliphatic and other medium liquids. There are two types of side mounted anti-corrosion magnetic flap level gauges, with stainless steel main body lined with polytetrafluoroethylene (PTFE) and stainless steel lined with polypropylene (PP), suitable for measuring corrosive media.
The side mounted lined magnetic flap level gauge (PTFE) is suitable for measuring liquid levels in corrosive media and high operating temperatures. It adopts a new process of stainless steel lined PTFE stretching and flanging, with reliable structure and long service life. It is a good choice for measuring the liquid level of highly corrosive media such as sulfuric acid.
The side mounted lined magnetic flap level gauge (PP) is suitable for measuring inorganic corrosive liquids such as hydrochloric acid and dilute sulfuric acid. Due to the use of imported high-strength materials that can be close to metals, especially the insulation properties of PPR *, this product is suitable for outdoor water tank level measurement and will not freeze inside in winter But it is not as good in temperature and pressure resistance as PTFE lining, and this product has a higher cost-effectiveness when the temperature and pressure are lower.
2、 Characteristics of concentrated sulfuric acid level gauge:
1. Using a float as the measuring element and a magnetic steel driven flip column display, no energy is required.
2. Equipped with upper and lower limit switch outputs, it can achieve remote alarm and limit control.
3. Equipped with a transmitter, remote liquid level indication, detection, and control can be achieved.
3、 Installation and maintenance of concentrated sulfuric acid level gauge
1. The installation of the liquid level gauge must be vertical to ensure that the float component can move freely up and down inside the main pipe.
2. Magnetic conductors are not allowed to approach the main body of the liquid level gauge, otherwise it will directly affect the correct operation of the liquid level gauge.
3. After the installation of the liquid level gauge is completed, it needs to be calibrated with magnetic steel to guide the flip column once, so that the display below the zero position is red and the display above the zero position is white.
4. When the liquid level gauge is put into operation, the valve of the lower drainage pipe should be opened first to allow the liquid medium to smoothly enter the main pipe, avoiding the liquid medium from rapidly rising with the floating ball component, which may cause failure and disorderly flipping of the column. If this phenomenon occurs, it can be recalibrated with magnetic steel after the liquid level stabilizes.
4、 Basic technical parameters of concentrated sulfuric acid level gauge:
1. Range: above 300mm;
2. Medium density: ≥ 0.4g/cm3;
3. Medium viscosity: ≤ 0.02Pa.S;
4. Working temperature: PP-40~80 ℃, PTFE -40~150 ℃;
5. Pressure rating: ≤ 32MPa;
6. Measurement accuracy: L=500~1000mm ≤ 1.5% FS, L>1000mm ≤ 1.0% FS;
7. Installation methods: side mounted, top mounted;
8. Protection level: IP65;
9. Explosion proof level: ib Ⅱ CT4 (intrinsic safety type), d Ⅱ BT4 (explosion-proof type);
10. Transmission mode: 4-20mA or switch quantity;
11. Wetting material: PP, PTFE;
12. Float material: 316L, PVC/UPVC/CPVC/PTFE/titanium, etc.
5、 Application and scope of concentrated sulfuric acid level gauge:
type |
model |
Scope and Application |
普通型 |
SURE-UHZ -P |
Ordinary float level gauge is a type of on-site display instrument widely used in petroleum, chemical, power, light industry, environmental protection and other departments to continuously display the liquid level in open or pressure vessels. |
corrosion-resistant type |
SURE-UHZ- F |
Especially suitable for liquid level measurement indicators with corrosiveness and toxicity (working pressure ≤ 1.6MPa); Measurement range ≤ 2m). |
Heat tracing type |
SURE-UHZ- R |
Suitable for measuring liquid media with high viscosity, high or low temperature (this instrument requires the use of a heat tracing device). |
high-temperature type |
SURE-UHZ- T |
Suitable for continuous liquid level measurement of liquid media with container pressure less than 10Mpa and temperature between 200 ℃ and 450 ℃. |
High voltage type |
SURE-UHZ- Y |
Suitable for measuring the liquid level of liquid media in closed containers with temperatures below 200 ℃ and process pressures above 10Mpa (below 20Mpa). |
High temperature and high pressure type |
SURE-UHZ- H |
Suitable for measuring the liquid level of liquid media in closed containers with temperatures above 200 ℃ and process pressures above 10Mpa (below 20Mpa). |
Explosion-proof type |
SURE-UHZ -B |
This instrument is suitable for situations where remote transmission of electrical signals is required in flammable and explosive environments. It comes with electronic devices such as 4mA to 20mA current signals or liquid level transmitters with upper and lower limit alarm settings. |
Top mounted type |
SURE-UHZ -D |
Suitable for various underground fluid storage tanks, it can display liquid level on the ground. Not suitable for working environments with strong vibrations and strong magnetism (working pressure ≤ 1.6MPa); Measurement range ≤ 2m).
|
6、 Thick Sulfuric acid level gauge model and description:
|
SURE-UHZ |
Manufacturer Code |
|||||||||||||
|
code name |
meaning |
T |
high-temperature type |
basic type |
|||||||||
|
P |
普通型 |
Y |
High voltage type |
||||||||||
|
D |
Top mounted type |
H |
High temperature and high pressure type |
||||||||||
|
F |
corrosion-resistant type |
B |
Explosion proof type (Bd is explosion-proof type, Bi is intrinsic safety type) |
||||||||||
|
R |
Heat tracing type |
|
|
||||||||||
|
code name |
meaning |
4 |
4.0 |
process pressure (MPa) |
|||||||||
|
0 |
atmospheric pressure |
5 |
6.3 |
||||||||||
|
1 |
1.0 |
6 |
10.0 |
||||||||||
|
2 |
1.6 |
7 |
15.0 |
||||||||||
|
3 |
2.5 |
8 |
other |
||||||||||
|
code name |
meaning |
4 |
0.75-0.9 |
medium density (g∕cm3) |
|||||||||
|
1 |
0.45-0.51 |
5 |
0.9-1.0 |
||||||||||
|
2 |
0.51-0.65 |
6 |
1.0-1.8 |
||||||||||
|
3 |
0.65-0.75 |
|
|
||||||||||
|
code name |
meaning |
2 |
PVC/ UPVC |
Main material |
|||||||||
|
0 |
304 |
3 |
Lining F4 (or PE) |
||||||||||
|
1 |
316/ 316L |
4 |
other |
||||||||||
|
0 |
Column flipping on-site display type |
display mode |
|||||||||||
|
1 |
Transmission output type |
||||||||||||
|
2 |
Flip column with transmission output type |
||||||||||||
|
3 |
other types |
||||||||||||
|
0 |
No alarm point |
Alarm code |
|||||||||||
|
1 |
There is an alarm point |
||||||||||||
|
2 |
There are two alarm points |
||||||||||||
|
3 |
other |
||||||||||||
|
X |
Other content such as range (L) |
Other options |
|||||||||||
A brief introduction to sulfuric acid level gauge:
*Liquid level gauges can be used for medium level detection in various equipment such as towers, tanks, tanks, spherical vessels, and boilers. This series of liquid level gauges can achieve high sealing, leak prevention, and are suitable for high temperature, high pressure, and corrosion-resistant applications. It compensates for the defects of poor clarity and easy breakage of glass plate (tube) level gauges, and the entire measurement process has no blind spots, clear display, and a large measurement range. The components of the magnetic flap level gauge are made of materials such as 1Cr18Ni9Ti, 316L, 0Cr18Ni9Ti, 1Cr18Ni9Ti lined with PTFE (polytetrafluoroethylene), PVC, PP, and imported components, which have high reliability and corrosion resistance.
Overview of sulfuric acid level gauge:
The sulfuric acid level gauge is an internal float level gauge developed by our company based on the production of plate and tube level gauges using new foreign technologies. Due to the use of stainless steel materials for its pressure bearing parts, the sealing interface is reduced in structure, thus improving the safety and reliability of the instrument. The liquid level display is clear and eye-catching.
Principle of sulfuric acid level gauge:
The sulfuric acid level gauge consists of a body (composed of upper and lower conduits), a flip box (composed of red and white dual color magnetic flip plates), a float (composed of a magnet, a top rod, and a float), etc. The working principle is that the float in the container (developed according to different media and pressures) floats up and down in the lower conduit with the change of liquid level height, and the magnet moves up and down in the upper conduit through the top rod, causing the outer flip plate to flip and indicating the liquid level height with red and white colors.
Parameters of sulfuric acid level gauge:
1. Measurement range (center to center distance between upper and lower flanges): L=500-6000mm, special orders can be placed for sizes exceeding 6000mm;
2. Indication error: ± 10mm
3. Work pressure: Normal type: ≤ 6.3MPA, High pressure type: 6.3-16MPA;
4. Medium temperature: ordinary type: ≤ 150 degrees, high temperature type: 150-450 degrees;
5. Medium density: ≥ 0.45g/m ³;
6. Density difference: ≥ 0.15g/m ³ (measurement interface);
7. Wetting material: Standard 1Cr18Ni9Ti. Different grades of stainless steel such as 304, 316, 316L, 316Ti, 317, 317L, S2205, Ti, etc. can be selected according to the chemical properties of the tested medium to achieve anti-corrosion purposes;
8. Connection flange specifications: DN20, DN25, special specifications require customization.
Characteristics of sulfuric acid level gauge:
1. When the side opening of the container is not suitable and there is little space around the container, this type of liquid level gauge can be installed on the upper or lower part of the container
2. Suitable for liquid media with high viscosity
3. The viewing direction of the monitor can be changed arbitrarily
4. Install liquid level switch transmitter and control switch, which can be installed and adjusted at any time without stopping the machine.
5. If the power supply is interrupted, switch it on site. It is also unaffected and has high accuracy.
6. Add different colored liquids every 10 minutes to make the liquids easily recognizable.
Sulfuric acid level gauge model:
model |
code |
Instructions |
||||||
WK -UHZ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
|
Installation method |
C |
|
|
|
|
|
|
When installing on the side |
Main material |
|
1 |
|
|
|
|
|
ABS (only applicable when nominal pressure is 0.6MPa) |
Nominal Pressure |
|
|
1 |
|
|
|
|
0.6MPa |
type |
|
|
|
1 |
|
|
|
Basic type |
Installation spacing |
|
|
|
|
L |
|
|
Measurement range conversion |
Installation depth |
|
|
|
|
|
L1 |
|
Top mounted, optional from 0 to 3000mm |
medium density |
|
|
|
|
|
|
ρ |
g/cm3 |
Note:
1. When the side mounted type is made of stainless steel material, the measurement range is equal to the installation spacing. When using ABS material, the measurement range is equal to the installation spacing of L-150mm.
2. Installation spacing (measurement range) size series: 500, 800, 1100, 1400, 1700, 2000, 2500, 3000, 3500, 4000, 4500, 5000