E-mail
lyboiler@163.com
-
Phone
1580901009
-
Address
Linyi City, Shandong Province
Shandong Tiancheng Boiler Installation Co., Ltd
lyboiler@163.com
1580901009
Linyi City, Shandong Province
Product Code: FR0001
Product Name: Q Series Waste Heat Boiler for Industrial Applications such as Chemical, Sulfuric Acid, and Building Materials
Specification: Q QCF
Q serieswaste heat boilerSeries product features
Utilizing the waste heat generated during the production process to produce steam can save energy, reduce consumption, and improve efficiency for enterprises
The waste heat boiler has a compact structure, good sealing performance, no environmental pollution, low system resistance, easy operation, safety and reliability, and can ensure full recovery of waste heat.
The waste heat boiler is designed according to the user's process parameters.
We have developed and successfully operated waste heat boilers in the following industries: carbon black industry, glass fiber industry, coking industry, metallurgy and steel industry, petroleum industry, acid and alkali industry, and cement industry.
|
Main performance parameters |
||||
|
Boiler model project |
Q40/850 -12-1.25 |
Q50/900-15-1.25/300 Q50/900-15-1.6/300 |
Q60/900 -20-1.8 |
Q66/900 -25-1.25/300 |
|
Rated evaporation capacity t/h |
12 |
15 |
20 |
25 |
|
Rated working pressure Mpa |
1.25 |
1.26/1.6 |
1.8 |
1.25 |
|
Smoke flow rate (peak) Nm 3/h |
40000 |
50000 |
60000 |
66000 |
|
Imported flue gas temperature ℃ |
850 |
900 |
900 |
900 |
|
Rated steam temperature ℃ |
194 |
300 |
210 |
300 |
|
Heating surface area of the body m 2 |
638 |
842.5/871.7 |
958 |
1604 |
|
Heating area of superheater m 2 |
/ |
30.5 |
/ |
70.5 |
|
Heating area of economizer m 2 |
/ |
/ |
/ |
750 |
|
Heating surface area of air preheater m 2 |
/ |
/ |
/ |
501 |
|
System resistance Pa |
<2000 |
<1500 |
<1000 |
<2000 |
|
Maximum weight of the transported item t |
38.9 |
bulk |
bulk |
bulk |
|
Scope of Application |
chemical industry |
chemical industry |
chemical industry |
chemical industry |
|
Main performance parameters of waste heat boiler |
|||||
|
Boiler model project |
Q80/900 -25-2.5 |
Q75/900 -25-3.82/450 |
Q110/900 -35-8.32/450 |
Q130/950 -35-3.82/450 |
Q160/900 -50-3.82/450 |
|
Rated evaporation capacity t/h |
25 |
25 |
35 |
35 |
50 |
|
Rated working pressure Mpa |
2.5 |
3.82 |
3.82 |
3.82 |
3.82 |
|
Smoke flow rate (peak) Nm 3/h |
80000 |
75000 |
11000 |
130000 |
160000 |
|
Imported flue gas temperature ℃ |
900 |
900 |
900 |
950 |
900 |
|
Rated steam temperature ℃ |
226 |
450 |
450 |
450 |
450 |
|
Heating surface area of the body m 2 |
1496 |
1145 |
1710 |
1961 |
2403 |
|
Heating area of superheater m 2 |
/ |
171 |
185 |
270 |
320.5 |
|
Heating area of economizer m 2 |
/ |
1660 |
830 |
984 |
/ |
|
Heating surface area of air preheater m 2 |
/ |
/ |
945 |
/ |
/ |
|
System resistance Pa |
<1000 |
<1500 |
<1600 |
<1600 |
<2000 |
|
Maximum weight of the transported item t |
bulk |
bulk |
bulk |
bulk |
bulk |
|
Scope of Application |
chemical industry |
chemical industry |
chemical industry |
chemical industry |
chemical industry |
|
Main performance parameters of waste heat boiler |
||||
|
Boiler model project |
Q12/300 -1.2-1.25 (Water, gas, etc.) Waste heat recovery |
Q6/1000 -2-1.25 (Sulfuric acid process) Waste heat recovery |
Q10/1000 -4-1.25/350 |
Q15/900 -4-1.25/280 Q15/900-4-1.6/280 |
|
Rated evaporation capacity t/h |
1.2 |
2 |
4 |
4 |
|
Rated working pressure Mpa |
0.25 |
1.25 |
1.25 |
1.25/1.6 |
|
Smoke flow rate (peak) Nm 3/h |
12000 |
6000 |
10000 |
15000 |
|
Imported flue gas temperature ℃ |
300 |
1000 |
1000 |
900 |
|
Rated steam temperature ℃ |
138 |
194 |
350 |
280 |
|
Heating surface area of the body m 2 |
248 |
70 |
84 |
278/292 |
|
Heating area of superheater m 2 |
/ |
/ |
115 |
7.1 |
|
System resistance Pa |
<500 |
<500 |
<1000 |
<1000 |
|
Maximum weight of the transported item t |
18.2 |
12 |
24.5 |
22.7/24.5 |
|
Scope of Application |
chemical industry |
Sulfuric acid production from sulfur |
Sulfuric acid production from sulfur |
chemical industry |
|
Main performance parameters of waste heat boiler |
||||
|
Boiler model project |
QCF10/950-5 -2.45/400 |
Q18/900-6- 1.25/280 Q18/900-6- 1.6/280 |
Q26/900-8- 1.25/250 Q26/900-8- 1.6/280 |
Q36/900-10- 1.25/250 Q36/900-10- 1.6/250 |
|
Rated evaporation capacity t/h |
5 |
6 |
8 |
10 |
|
Rated working pressure Mpa |
2.45 |
1.25/1.6 |
1.25/1.6 |
1.25/1.6 |
|
Smoke flow rate (peak) Nm 3/h |
10000 |
18000 |
26000 |
36000 |
|
Imported flue gas temperature ℃ |
950 |
900 |
900 |
900 |
|
Rated steam temperature ℃ |
400 |
280 |
250/280 |
250/280 |
|
Heating surface area of the body m 2 |
150 |
371.3 |
418/436 |
506 |
|
Heating area of superheater m 2 |
30 |
9.46 |
9.55 |
12.4 |
|
System resistance Pa |
<1000 |
<1000 |
<1000 |
<1000 |
|
Maximum weight of the transported item t |
bulk |
25.4/28.2 |
32.4 |
38.8 |
|
Scope of Application |
Sulfuric acid production from pyrite |
chemical industry |
chemical industry |
chemical industry |