E-mail
lyboiler@163.com
-
Phone
1580901009
-
Address
Linyi City, Shandong Province
Shandong Tiancheng Boiler Installation Co., Ltd
lyboiler@163.com
1580901009
Linyi City, Shandong Province
Shandong Huayuan Boiler Co., LtdProduct Features
The boiler body is designed with double drum, single-layer layout, compact structure, and a large heating surface. The heating surface of the boiler is 10% larger than that of similar products, and it has the characteristics of sufficient output, safety and reliability, short construction period, and low installation cost.
The furnace is equipped with a cyclone burnout chamber, which reduces the dust content in the flue gas. At the same time, the hot carbon black particles are further burned, improving the thermal efficiency of the boiler and reducing the blackness of the flue gas. The concentration of smoke and dust emissions meets the requirements of Class I environmental protection areas.
The grate adopts patented technologies such as small roller structure and edge grate plates, greatly improving the reliability of boiler operation.
The closed type air chamber and double-sided furnace exhaust adjustment device are patented technologies protected by the state. They adopt a mechanically processed conical sealing structure to improve the sensitivity of furnace exhaust adjustment.
This series of boilers has been rated as first-class by the Ministry of Mechanical and Electrical Engineering, and is a national energy-saving promotion product and an excellent energy-saving product in Shandong Province.
According to user requirements, layered combustion devices and other energy-saving equipment promoted by the country can be matched.
|
Main Performance Parameters of SZL Series Hot Water Boiler |
||||
|
Boiler model project |
SZL4.2-0.7/ 95 60 / 70 45 -AII |
SZL5.6-0.7/95/ 70-AII |
SZL7.0-1.0/115/ 70-AII |
SZL10.5-1.0/115/ 70-AII |
|
Rated thermal power (MW) |
4.2 |
5.6 |
7.0 |
10.5 |
|
Rated working pressure Mpa |
0.7 |
0.7 |
1.0 |
1.0 |
|
Rated outlet temperature ℃ |
95 ( 65 ) |
95 |
115 |
115 |
|
Rated return water temperature ℃ |
70 ( 45 ) |
70 |
70 |
70 |
|
combustion mode |
Chain grate |
Chain grate |
Chain grate |
Chain grate |
|
Adapt to coal types |
AII 、 AIII |
AII 、 AIII |
AII 、 AIII |
AII 、 AIII |
|
Furnace grate area |
7.23 |
9.9 |
11.99 |
17.38 |
|
Heating surface area of the body m 2 |
157.6 |
240.2 |
243.2 |
324 |
|
Heating area at the tail of the boiler m 2 |
/ |
/ |
174.4 |
236 |
|
Coal consumption during full load operation (Kg/h) |
896.6(943) |
1186.6 |
1507.6 |
2258 |
|
Exhaust gas temperature ℃ |
175(161) |
175 |
170 |
170 |
|
Smoke and dust emission concentration (mg/Nm 3) |
<80 |
<80 |
<80 |
<80 |
|
Appraisal thermal efficiency% |
79.2* |
79.59* |
82.17 |
82.3 |
|
Maximum transportation size (length x width x height) |
7830x3480x3460 |
6720x3400x3540 |
8800x3230x2600 |
9900x3400x3530 |
|
Maximum transportation weight t |
36 |
26.4 |
30.15 |
36 |
|
Dimensions after installation (length x width x height) |
8370x5330x3860 |
9000x5000x5600 |
11320x3600x5400 |
13000x4500x5800 |
|
Note: 1. The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/kg) 2. If there are any changes to the "product performance parameters" marked, the technical documents of the product at the factory shall prevail. |
||||
|
Main performance parameters of SZL series organizational hot water boilers |
|||
|
Boiler model project |
SZL SZL5.6-0.7/95/70-AII(Q) |
SZL 14-1.0/115/70-AII |
SZL 10 7 - 1.0/115/70 1.25 -AII |
|
Rated thermal power (MW)/rated evaporation rate t/h |
5.6 |
14 |
7(10) |
|
Rated working pressure Mpa |
0.7 |
1.0 |
1.0(1.25) |
|
Rated outlet temperature ℃ Rated steam temperature ℃ |
95 |
115 |
115(194) |
|
Rated return water temperature ℃ |
70 |
70 |
70 |
|
combustion mode |
Chain grate |
Chain grate |
Chain grate |
|
Adapt to coal types |
AII 、 AIII 、 gas |
AII 、 AIII |
AII 、 AIII |
|
Furnace grate area |
9.9 |
21.33 |
11.99 |
|
Heating surface area of the body m 2 |
240.2 |
440 |
232.3 |
|
Heating area at the tail of the boiler m 2 |
/ |
233 |
52.7 |
|
Coal consumption during full load operation (Kg/h) |
1186 |
2938 |
1407 ( 1507.3 |
|
Exhaust gas temperature ℃ |
175 |
170 |
195 ( 170 |
|
Smoke and dust emission concentration (mg/Nm 3) |
<80 |
<80 |
<80 |
|
Appraisal thermal efficiency% |
79.59* |
82.5 |
78.28 (Water Furnace 76.75) |
|
Maximum transportation size (length x width x height) |
6720x3400x3540 |
10700x3550x3400 |
7570x3230x3540 |
|
Maximum transportation weight t |
26.4 |
41 |
33.3 |
|
Dimensions after installation (length x width x height) |
9000x5000x5600 |
14000x4730x7820 |
11800x4250x5750 |
|
Note: 1. The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/kg) 2. If there are any changes to the "product performance parameters" marked, the technical documents of the product at the factory shall prevail. |
|||