Product model, all of the following models are supportedMobile APP and mobile computer web monitoring function:
GRMOPCS-N can only access the internet through a network port, 500 points, only supports OPC, does not support SMS alarms
GRMOPCS-NW network port+wifi internet access, 500 points, only supports OPC, does not support SMS alerts
GRMOPCS-Q network port+mobile card for internet access, 500 points, only supports OPC, supports SMS alarm
GRMOPCS-QW network port+mobile card+wifi internet access, 500 points, only supports OPC, supports SMS alarm
GRMOPCM-N can only access the internet through a network port, 1000 points, supports various communication protocols+OPC, does not support SMS alerts
GRMOPCM-NW network port+wifi internet access, 1000 points, supports various communication protocols+OPC, does not support SMS alerts
GRMOPCM-Q network port+mobile card for internet access, 1000 points, supports various communication protocols+OPC, supports SMS alarm
GRMOPCM-QW network port+mobile card+wifi internet access, 1000 points, supports various communication protocols+OPC, supports SMS alarm
GRMOPCH-N can only access the internet through a network port, with 3000 points, supporting various communication protocols+OPC, does not support SMS alerts
GRMOPCH-NW network port+wifi internet access, 3000 points, supports various communication protocols+OPC, does not support SMS alerts
GRMOPCH-Q network port+mobile card for internet access, 3000 points, supports various communication protocols+OPC, supports SMS alarm
GRMOPCH-QW network port+mobile card+wifi internet access, 3000 points, supports various communication protocols+OPC, supports SMS alarm

Function Description
1. Support mobile APP, mobile and computer web monitoring configuration software data
2. Support SMS alarm and telephone voice alarm
3. If you need WeChat alarm, you need to purchase the option separately:http://www.shyk.com/pdetail.asp?baseid=3&secondid=&id=386
Product User Manual
Detailed description of GRMOPC and Siemens WINCC, Kingview, Force Control, IFIX, Intouch, RSView32, Kepware, etcCommunication Connection Tutorial for Various Configuration Software
GRMOPC Product User Manual Download
Taking Siemens WINCC as an example, the process of using SMS and WeChat alarms is as follows:
http://www.shyk.com/detail.asp?baseid=2&secondid=2010&id=399
Taking Siemens WINCC as an example, to achieve remote control of web pages and mobile apps:
http://www.shyk.com/detail.asp?baseid=2&secondid=2018&id=384
Program Features
1. OPC remote communication does not require configuring DCOM, and the entire solution does not require fixed IP and dynamic domain names.
2. Solve the problem of accessing OPC across network segments. Any computer that can access the internet through configuration software can remotely access the data in the monitoring center configuration software.
3. The original monitoring system is OPCSERVER and does not require any changes.
4. The original monitoring system's industrial computer is not connected to the external network, fundamentally preventing viruses and network intrusions.
5. GRMOPC can choose to turn off or disconnect from the internet. Remote OPC access requires password authentication.
6. Use Ethernet cable and 4G (full network) internet access, dual line backup, and dual power supply.
7. All data can be read and written with optional permissions to ensure system security.
8. The computer comes with Guard monitoring, which automatically resets to prevent OPC driver errors or unintentional exits,
9. Open interface, customers can develop APP and web backend.
Application scenarios
Different from the traditional GRM500 that directly obtains data from devices or PLCs, the application scenarios of GRM-OPC remote system are as follows:
1. The client's upper computer system (such as configuration software, DCS) has been set up.
2. The upper computer system is connected to numerous devices with different drivers.
3. The PLC and instruments are too scattered, and the data has already been centralized to the upper computer, making it inconvenient to rewire.
4. PLC does not have additional interfaces and cannot be directly read from PLC or equipment.
5. Without a PLC program, it is impossible to add a communication module to the hardware configuration.
Without a data address table for the PLC, data cannot be directly read from the PLC.
The customer's requirement is that the configuration software can support OPCSERVER, which is a commonly used configuration software in the market, including DCS.
If the site has the conditions to directly read data from the PLC, it is recommended to use the GRM500 series
Model selection

Communication configuration between GRMOPC intelligent terminal and industrial control computer configuration software:
The configuration software variables that need to be read by the configuration module have flexible filtering, searching, and automatic import functions.
1. Download locally through Ethernet cable
2. Use the 'Remote Download Password' to download from the network

GRMOPC intelligent terminal realizes remote monitoring function demonstration: