SF6 leakage monitoring device

NegotiableUpdate on 01/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The "Electricity Safety Work Regulations" (for power plants and substations) specifically stipulate that the distribution equipment room equipped with SF6 equipment must ensure that the SF6 concentration is less than 1000ppm. In addition to installing strong ventilation devices, monitoring devices such as oxygen meters and SF6 leakage monitoring devices that can alarm must also be installed.
Product Details

SF6 leakage monitoring deviceTechnical background:

SF6 gas has insulation properties, strong arc extinguishing ability, good thermal and chemical stability, is non flammable and non-toxic. Therefore, SF6 gas has become an insulating and arc extinguishing medium, and it can be said that SF6 gas is the cornerstone of modern high-voltage, ultra-high voltage, and ultra-high voltage combination electrical appliances. SF6 gas is currently used as an insulation medium, especially in the fields of high voltage and ultra-high voltage, and its technological maturity and economic feasibility have not been replaced. SF6 gas greenhouse effect is one of the six greenhouse gases with clear emission restrictions. Its GWP value is over 20000 times that of CO2. SF6 gas has an extremely long atmospheric lifespan, and once leaked, it can remain stable in the atmosphere for over 3000 years, indicating that its greenhouse effect is cumulative and irreversible. SF6 gas decomposition produces a series of toxic and corrosive decomposition products such as sulfur fluoride SF4, S2F2, and sulfuryl fluoride SOF2. When maintenance personnel enter the gas chamber where discharge faults have occurred or recover gas, inadequate protection can pose a serious threat to personal safety. These decomposition products are also corrosive and can corrode the insulation materials and metal components inside the equipment, affecting its long-term reliability. Therefore, the "Electricity Safety Work Regulations" (for power plants and substations) specifically stipulate that the distribution equipment room equipped with SF6 equipment must ensure that the SF6 concentration is less than 1000ppm. In addition to installing strong ventilation devices, monitoring devices such as oxygen meters and SF6 gas concentration detection alarm devices that can alarm must also be installed.

SF6泄漏监测装置

SF6 leakage monitoring deviceFunction:

SF6 gas concentration detection function in the environment

Oxygen concentration detection function in the environment

Temperature and humidity detection function in the environment

Real time display function of telemetry and remote signaling for all monitoring points in the environment

Real time display of alarm information for all monitoring points in the environment

Fixed value setting function

SF6 gas concentration exceeding the standard and oxygen deficiency alarm function

Oxygen deficiency or excessive SF6 concentration, forced exhaust function

Automatic fan start function upon alarm

Timed automatic exhaust function

Manually force all fans to turn on or off,

Historical data query, display, and storage functions

Remote telemetry historical curve trend query and display function

Enter the GIS room and automatically report the current environmental status function

Multi monitoring point configuration function in different regions

Multi point networking function, can provide communication protocol and substation backend database docking (reserved)

Provide a universal communication interface and reserve the ability to interface with backend monitoring and fire protection systems (reserved)

Alarm information storage and recording function

Sound and light, voice alarm function

Remote alarm function

Human infrared detection and sensing function

Data remote transmission function

SF6泄漏监测装置