The SY series multifunctional tablet analyzer has been used in the field of drug analysis for over 40 years, strictly following the current standards of the Chinese Pharmacopoeia and the consistency evaluation standards for generic drugs. The SY-6DN intelligent tablet four purpose tester integrates four functions: dissolution rate, disintegration time limit, tablet hardness, and tablet brittleness. It is widely used in pharmaceutical companies, pharmaceutical research, teaching and research, and drug testing departments.
Multifunctional: dissolution rate, disintegration time limit, tablet hardness, tablet fragility.
Smaller volume, reducing the footprint of laboratory workbenches.
Built in three-level user permission management, audit tracking, and test record management. Test reports can be printed or USB output through device interfaces.
Common sample information management for easy retrieval and use.
High precision real-time constant temperature control, with dual over temperature protection and temperature calibration functions.
There is an internal reservation heating system, and users can set the system to start heating at a specified time.
The dissolution cup and mixer are automatically centered.
Use more convenient water circulation pipeline design and professional medical grade quick connectors.
The visible window above the hardness testing chamber provides a clear and intuitive view of each testing process.
The hardness can be tested continuously for 1000 times, and the interval between consecutive tests can be adjusted by the user.
Free provision of IQ/OQ certification documents.
Shanghai Huanghai Drug Testing SY-6DN Intelligent Tablet Four purpose TesterTechnical Specifications
Dissolution parameter
Dissolution channel: 6 channels
Mixing slurry swing amplitude: ≤ 0.5mm
Swing amplitude of basket: ≤ 1.0mm
Deviation between the rotating rod and the dissolution cup shaft: ≤ 1.0mm
Speed setting range: 10~300RPM
Steady speed error: ≤± 1%
Temperature regulation range: Room temperature~45.0 ° C
Temperature resolution: 0.1C
Temperature control accuracy: ≤± 0.3 ℃
Disintegration time limit parameter
Collapse basket: 1 set (6 tubes)
Hanging basket lifting frequency: 30-32 times/minute
Hanging basket lifting amplitude: 55 ± 1.0mm
Minimum distance from sieve to cup bottom: 25 ± 1.0mm
Mesh aperture: standard 2.0mm, optional 0.42mm, 0.71mm, 1.0mm
Disintegration time limit: ≤ 100 times
Disintegration timing time: ≤ 999 hours, 59 minutes, and 59 seconds
Tablet hardness parameters
Hardness measurement range: 10~350N
Resolution: 0.01N
Accuracy: ± 1.5% ± 1digit
Unit: N/kg (optional)
Measurement method: Automatic single/continuous multiple times (up to 1000 times)
Diameter measurement range: 2-25mm
Resolution: 0.1mm
Accuracy: ± 0.1mm
Fragility parameters of tablets
Number of drum wheels: 1 set
Wheel drum size: inner diameter approximately 286mm, depth 39mm
Default speed: 25RMP
Speed setting range: 20~50RPM
Default number of turns: 100 turns
Range of circle setting: 1-1000 circles
Rotation direction: clockwise/counterclockwise
temperature parameter
Temperature regulation range: Room temperature~45.0 ° C
Temperature resolution: 0.1C
Temperature control accuracy: ≤± 0.3 ℃
Power supply: AC220V ± 10%, 50Hz