Product features of Shandong Huayuan Boiler Co., Ltd. ● The boiler body is designed with double drum, single-layer layout, compact structure, and large heating area. The heating surface of the boiler is 10% more than similar products, which has the characteristics of sufficient power, safety and reliability, short construction period, and low installation cost

Product Details

Shandong Huayuan Boiler Co., LtdProduct Features
The boiler body is designed with double drum, single-layer layout, compact structure, and large heating surface. The heating surface of the boiler is 10% more than similar products, which has the characteristics of sufficient power, safety and reliability, short construction period, and low installation cost.
The furnace is equipped with a cyclone burnout chamber, which reduces the dust content in the flue gas. At the same time, the hot carbon black particles are further burned, improving the thermal efficiency of the boiler and reducing the blackness of the flue gas. The smoke and dust emission concentration meets the requirements of a first-class environmental protection area.
The grate adopts patented technologies such as small roller structure and edge grate plates, greatly improving the reliability of boiler operation.
The closed type air chamber and double-sided furnace exhaust adjustment device are patented technologies protected by the state. They adopt a mechanically processed conical sealing structure to improve the sensitivity of furnace exhaust adjustment.
This series of boilers has been rated as first-class by the Ministry of Mechanical and Electrical Engineering, and is a national energy-saving promotion product and an excellent energy-saving product in Shandong Province.
According to user requirements, layered combustion devices and other energy-saving equipment promoted by the country can be matched.

Main performance parameters of SZL series assembled steam boilers

Boiler model

project

SZL

6-1.25

/1.6-AII

SZL

6-2.5-AII

SZL

8-1.25

/1.6-AII

SZL

8-2.5-AII

SZL

10-1.25

/1.6-AII

SZL

10-2.5-AII

SZL

10-1.25

/350-AII

SZL

10-2.5

/400-AII

Rated evaporation capacity t/h

6

6

8

8

10

10

10

10

Rated steam pressure Mpa

1.25/1.6

2.5

1.25/1.6

2.5

1.25/1.6

2.5

1.25

2.5

Rated steam temperature ℃

saturation

saturation

saturation

saturation

saturation

saturation

350

400

combustion mode

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Adapt to coal type (bituminous coal)

AII-AIII

AII-AIII

AII-AIII

AII-AIII

AII-AIII

AII-AIII

AII-AIII

AII-AIII

Effective area of grate m 2

7.2

7.2

9.9

9.9

11.99

13.1

13.1

13.1

Heating surface area of the body m 2

158.8

158.8

224.1

224.1

244/232.3

242.3

291.5

294.6

Heating area at the tail of the boiler m 2

87.2

105

105

125

174.4/244

244

229.6

265

Coal consumption during full load operation (Kg/h)

968/971

972

1287/1289

1293

1380/1386

1394

1618

1673

Exhaust gas temperature ℃

170

170

170

170

170

170

170

170

Smoke and dust emission concentration (mg/Nm 3)

<80

<80

<80

<80

<80

<80

<80

<80

Appraisal thermal efficiency%

78.08

78.08

78.08

78.08

78.28

78.28

78.28

82.17

Longest transport size (length x width x height) mm

5370x2970

x3550

5740x2830

x3550

6720x3370

x3550

6720x3370

x3550

7530x3340

x3550

8830x3340

x3550

8830

x3370

x3550

8800

x3400

x3550

Maximum weight of the transported item t

21.5/22.2

24.2

26.4/28

28.6

31/36

38

37.6

37.6

Dimensions after installation (length x width x height) mm

8200x2970

x5600

8200x2830

x5600

8200x3370

x5600

8200x3370

x5600

1210x3800

x6030

1350

x3800

x6030

1350

x3800

x6500

1210

x4500

x6190

Note: 1. The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/kg), and the thermal efficiency band * is the design thermal efficiency

2. If there are any changes to the "product performance parameters" marked, the technical documents of the product at the factory shall prevail.


Main performance parameters of SZL series assembled steam boilers

Boiler model

project

SZL15-1.25

/1.6-AII

SZL

15-2.5

-AII

SZL

15-1.25

/300-AII

SZL

15-2.5

/400-AII

SZL

20-1.25

/1.6-AII

SZL

20-2.5- AII

SZL

20-1.6

/300- AII

SZL

20-2.5

/400-AII

Rated evaporation capacity t/h

15

15

15

15

20

20

20

20

Rated working pressure Mpa

1.25/1.6

2.5

1.25

2.5

1.25/1.6

2.5

1.6

2.5

Steam temperature ℃

saturation

saturation

300

400

saturation

saturation

300

400

combustion mode

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Adapt to coal type (bituminous coal)

AII-AIII

AII-AIII

AII-AIII

AII-AIII

AII-AIII

AII-AIII

AII-AIII

AII-AIII

Effective area of grate m 2

17.38

18.84

18.84

18.84

21.33

24

22.1

24

Heating surface area of the body m 2

324

374.3

408.3

455.3

441

459

478.7

554

Heating area at the tail of the boiler m 2

330.5/354

3625

238

362

317

481

576

576

Coal consumption during full load operation (Kg/h)

2123/2130

2121

2333

2510

2726

2743

3083

33330

Exhaust gas temperature ℃

170

170

170

170

170

170

170

170

Smoke and dust emission concentration (mg/Nm 3)

<80

<80

<80

<80

<80

<80

<80

<80

Appraisal thermal efficiency%

78.3/82.3

79

79

79

82.5

82.5

80.4

82.5

Longest transport size (length x width x height) mm

9900x3400x3530

10020

x3480

x3740

10020

x3480

x3740

10020

x3480

x3740

10700

x3550

x3400

10700

x3550

x3400

10750

x3550

x3400

10700

x3550

x3400

Maximum weight of the transported item t

36.7/38

39.7

39.7

39.7

41/43.4

47.8

44

48

Dimensions after installation (length x width x height) mm

14000

x3400

x5800

14200

x3400

x6300

14500

x4600

x7300

14300

x5400

x7400

15000

x5300

x7350

15000

x5500

x7350

15700

x5460

x8340

15700

x6100

x9430

Note: 1. The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/kg), and the thermal efficiency band * is the design thermal efficiency

2. If there are any changes to the "product performance parameters" marked, the technical documents of the product at the factory shall prevail.


Main performance parameters of SZL series assembled steam boilers

Boiler model

project

SZL

25-1.25

/1.6-AII

SZL

25.2.5

/400-AII

SZL

10-1.6

/350-AII(Q)

SZL

1.5-1.6/

350-AII(Q)

SZL

20-1.25

/350-AII(Q)

SZL

20-2.5/

400-AII(Q)

Rated evaporation capacity t/h

25

25

10

15

20

20

Rated working pressure Mpa

1.25/1.6

2.5

1.6

1.6

1.25

2.5

Steam temperature ℃

saturation

400

350

350

350

400

combustion mode

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Chain grate

Adapt to coal type (bituminous coal)

AII-AIII

AII-AIII

AII 、 AIII

Coke (high) furnace gas

AII 、 AIII

Coke (high) furnace gas

AII 、 AIII

Coke (high) furnace gas

AII 、 AIII

Coke (high) furnace gas

Effective area of grate m 2

26.1

28.64

13.1

16.5

24.89

15.51

Heating surface area of the body m 2

625.6

810.2

282.1

421.5

464

554

Heating area at the tail of the boiler m 2

445/496

506.5

209.2

543.2

444

388

Coal consumption during full load operation (Kg/h)

3088

3758

/

/

/

/

Exhaust gas temperature ℃

154

169

170

170

170

170

Smoke and dust emission concentration (mg/Nm 3)

<80

<80

<80

<80

<80

<80

Appraisal thermal efficiency%

80.18

80.3

80.4

80.6

80.18

83.6

Longest transport size (length x width x height) mm

10730x4040

x4460

10700x3550

x3400

8830x3370

x3550

10100x3500

x3750

10730x3550

x3940

10700x3550

x3400

Maximum weight of the transported item t

40/43.6

35

33

39

45

48

Dimensions after installation (length x width x height) mm

15300x5700

x7900

16300x6400

x9700

13000x4200

x7500

14300x5200

x7400

15500x5900

x8700

15700x6100

x8500

Note: 1. The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/kg), and the thermal efficiency band * is the design thermal efficiency

2. If there are any changes to the "product performance parameters" marked, the technical documents of the product at the factory shall prevail.