Shandong Huayuan Boiler Co., LtdProduct Features
The boiler body is designed with double drum, single-layer layout, compact structure, and large heating surface. The heating surface of the boiler is 10% more than similar products, which has the characteristics of sufficient power, safety and reliability, short construction period, and low installation cost.
The furnace is equipped with a cyclone burnout chamber, which reduces the dust content in the flue gas. At the same time, the hot carbon black particles are further burned, improving the thermal efficiency of the boiler and reducing the blackness of the flue gas. The smoke and dust emission concentration meets the requirements of a first-class environmental protection area.
The grate adopts patented technologies such as small roller structure and edge grate plates, greatly improving the reliability of boiler operation.
The closed type air chamber and double-sided furnace exhaust adjustment device are patented technologies protected by the state. They adopt a mechanically processed conical sealing structure to improve the sensitivity of furnace exhaust adjustment.
This series of boilers has been rated as first-class by the Ministry of Mechanical and Electrical Engineering, and is a national energy-saving promotion product and an excellent energy-saving product in Shandong Province.
According to user requirements, layered combustion devices and other energy-saving equipment promoted by the country can be matched.
Main performance parameters of SZL series assembled steam boilers Boiler model project SZL 6-1.25 /1.6-AII SZL 6-2.5-AII SZL 8-1.25 /1.6-AII SZL 8-2.5-AII SZL 10-1.25 /1.6-AII SZL 10-2.5-AII SZL 10-1.25 /350-AII SZL 10-2.5 /400-AII Rated evaporation capacity t/h 6 6 8 8 10 10 10 10 Rated steam pressure Mpa 1.25/1.6 2.5 1.25/1.6 2.5 1.25/1.6 2.5 1.25 2.5 Rated steam temperature ℃ saturation saturation saturation saturation saturation saturation 350 400 combustion mode Chain grate Chain grate Chain grate Chain grate Chain grate Chain grate Chain grate Chain grate Adapt to coal type (bituminous coal) AII-AIII AII-AIII AII-AIII AII-AIII AII-AIII AII-AIII AII-AIII AII-AIII Effective area of grate m 2 7.2 7.2 9.9 9.9 11.99 13.1 13.1 13.1 Heating surface area of the body m 2 158.8 158.8 224.1 224.1 244/232.3 242.3 291.5 294.6 Heating area at the tail of the boiler m 2 87.2 105 105 125 174.4/244 244 229.6 265 Coal consumption during full load operation (Kg/h) 968/971 972 1287/1289 1293 1380/1386 1394 1618 1673 Exhaust gas temperature ℃ 170 170 170 170 170 170 170 170 Smoke and dust emission concentration (mg/Nm 3) <80 <80 <80 <80 <80 <80 <80 <80 Appraisal thermal efficiency% 78.08 78.08 78.08 78.08 78.28 78.28 78.28 82.17 Longest transport size (length x width x height) mm 5370x2970 x3550 5740x2830 x3550 6720x3370 x3550 6720x3370 x3550 7530x3340 x3550 8830x3340 x3550 8830 x3370 x3550 8800 x3400 x3550 Maximum weight of the transported item t 21.5/22.2 24.2 26.4/28 28.6 31/36 38 37.6 37.6 Dimensions after installation (length x width x height) mm 8200x2970 x5600 8200x2830 x5600 8200x3370 x5600 8200x3370 x5600 1210x3800 x6030 1350 x3800 x6030 1350 x3800 x6500 1210 x4500 x6190 Note: 1. The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/kg), and the thermal efficiency band * is the design thermal efficiency 2. If there are any changes to the "product performance parameters" marked, the technical documents of the product at the factory shall prevail. Main performance parameters of SZL series assembled steam boilers Boiler model project SZL15-1.25 /1.6-AII SZL 15-2.5 -AII SZL 15-1.25 /300-AII SZL 15-2.5 /400-AII SZL 20-1.25 /1.6-AII SZL 20-2.5- AII SZL 20-1.6 /300- AII SZL 20-2.5 /400-AII Rated evaporation capacity t/h 15 15 15 15 20 20 20 20 Rated working pressure Mpa 1.25/1.6 2.5 1.25 2.5 1.25/1.6 2.5 1.6 2.5 Steam temperature ℃ saturation saturation 300 400 saturation saturation 300 400 combustion mode Chain grate Chain grate Chain grate Chain grate Chain grate Chain grate Chain grate Chain grate Adapt to coal type (bituminous coal) AII-AIII AII-AIII AII-AIII AII-AIII AII-AIII AII-AIII AII-AIII AII-AIII Effective area of grate m 2 17.38 18.84 18.84 18.84 21.33 24 22.1 24 Heating surface area of the body m 2 324 374.3 408.3 455.3 441 459 478.7 554 Heating area at the tail of the boiler m 2 330.5/354 3625 238 362 317 481 576 576 Coal consumption during full load operation (Kg/h) 2123/2130 2121 2333 2510 2726 2743 3083 33330 Exhaust gas temperature ℃ 170 170 170 170 170 170 170 170 Smoke and dust emission concentration (mg/Nm 3) <80 <80 <80 <80 <80 <80 <80 <80 Appraisal thermal efficiency% 78.3/82.3 79 79 79 82.5 82.5 80.4 82.5 Longest transport size (length x width x height) mm 9900x3400x3530 10020 x3480 x3740 10020 x3480 x3740 10020 x3480 x3740 10700 x3550 x3400 10700 x3550 x3400 10750 x3550 x3400 10700 x3550 x3400 Maximum weight of the transported item t 36.7/38 39.7 39.7 39.7 41/43.4 47.8 44 48 Dimensions after installation (length x width x height) mm 14000 x3400 x5800 14200 x3400 x6300 14500 x4600 x7300 14300 x5400 x7400 15000 x5300 x7350 15000 x5500 x7350 15700 x5460 x8340 15700 x6100 x9430 Note: 1. The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/kg), and the thermal efficiency band * is the design thermal efficiency 2. If there are any changes to the "product performance parameters" marked, the technical documents of the product at the factory shall prevail. Main performance parameters of SZL series assembled steam boilers Boiler model project SZL 25-1.25 /1.6-AII SZL 25.2.5 /400-AII SZL 10-1.6 /350-AII(Q) SZL 1.5-1.6/ 350-AII(Q) SZL 20-1.25 /350-AII(Q) SZL 20-2.5/ 400-AII(Q) Rated evaporation capacity t/h 25 25 10 15 20 20 Rated working pressure Mpa 1.25/1.6 2.5 1.6 1.6 1.25 2.5 Steam temperature ℃ saturation 400 350 350 350 400 combustion mode Chain grate Chain grate Chain grate Chain grate Chain grate Chain grate Adapt to coal type (bituminous coal) AII-AIII AII-AIII AII 、 AIII Coke (high) furnace gas AII 、 AIII Coke (high) furnace gas AII 、 AIII Coke (high) furnace gas AII 、 AIII Coke (high) furnace gas Effective area of grate m 2 26.1 28.64 13.1 16.5 24.89 15.51 Heating surface area of the body m 2 625.6 810.2 282.1 421.5 464 554 Heating area at the tail of the boiler m 2 445/496 506.5 209.2 543.2 444 388 Coal consumption during full load operation (Kg/h) 3088 3758 / / / / Exhaust gas temperature ℃ 154 169 170 170 170 170 Smoke and dust emission concentration (mg/Nm 3) <80 <80 <80 <80 <80 <80 Appraisal thermal efficiency% 80.18 80.3 80.4 80.6 80.18 83.6 Longest transport size (length x width x height) mm 10730x4040 x4460 10700x3550 x3400 8830x3370 x3550 10100x3500 x3750 10730x3550 x3940 10700x3550 x3400 Maximum weight of the transported item t 40/43.6 35 33 39 45 48 Dimensions after installation (length x width x height) mm 15300x5700 x7900 16300x6400 x9700 13000x4200 x7500 14300x5200 x7400 15500x5900 x8700 15700x6100 x8500 Note: 1. The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/kg), and the thermal efficiency band * is the design thermal efficiency 2. If there are any changes to the "product performance parameters" marked, the technical documents of the product at the factory shall prevail.