1st Floor, Building 13, 1881 Zhengbo Road, Fengxian District, Shanghai
SMART-2005Safety Operation Regulations for Ultrasonic Eddy Current Integrated Comprehensive Flaw DetectorIt has the characteristics of powerful functionality, *, good scalability, and easy portability. Its eddy current testing capability and the use of 10 bit A D 400MHz high-speed sampling, ultrasonic testing function, DSP digital processing technology, SMT processing technology, etc., all of these new design concepts perfectly combined with modern electronic and computer technology make this NDT portable instrument a comprehensive testing tool in the industryProduct.
Safety Operation Regulations for Ultrasonic Eddy Current Integrated Comprehensive Flaw DetectorFunctional information
·Automatic amplitude and phase measurement
·Impedance plan and time-based scan curve display
·Amplitude/phase/amplitude alarm
·Fast analog/digital electronic balancing
·Real time operation prompts with hotkey assistance
·Can transmit parameters and graphics with a microcomputer
·Capable of parameter, graphic storage, playback, and analysis functions
·Support mixing frequency
Technical Specifications
Size and weight:
Size: 255 × 186 × 107mm Weight: 2.6kg
Power supply: External power adapter: DC18V 4.7A, rechargeable solid-state lithium battery (14.8V 6.3AH)
Work environment:
Working temperature: -20 ℃~+55 ℃
Storage temperature: -20 ℃~+50 ℃
Relative humidity: not exceeding 85%
Ultrasonic testing:
1. Frequency range: 1-5, 0.5-15, 3-16MHz in three levels
2. Gain adjustment: 0-110dB, divided into 0.5/1/2/6dB steps
3. Detection methods: full wave, positive, negative, and radio frequency (RF)
4. Detection range: 3-9999mm (steel longitudinal wave) continuously adjustable, with a minimum display detection range of 3mm
5. Pulse shift: -10.0~2000.0mm (steel longitudinal wave)
6. Probe zero point: 0-199.99us
7. Material sound velocity: 1000-15000m/s
8. Damping: High/Medium/Low Three Levels
9. Inhibition: 0-90%, linear inhibition
10. Vertical linear error: ≤ 3%
11. Flaw detection sensitivity margin: ≥ 60dB
12. Far field resolution: ≥ 28dB
13. Horizontal linear error: ≤ 2%
14. DAC curve: can record up to 10 echo reference points, can change the distance between the three lines of DAC, and can correct the echo reference points
15. Gate: Two independent alarm gates, A and B. Gate A can be set to track gate mode, while Gate B can be set to widen the gate waveform
16. Measurement point selection: One can be selected inside the gateThe leading edge or peak of the echo
17. Memory: capable of storing 1000 sets of images and parameters
18. A-type echo freezing: can freeze A-type flaw detection images
Eddy current testing:
1. Frequency: 2
2. Frequency range: 64Hz to 5MHz
3. Automatic mixing unit: 1 unit
4. Automatic/manual amplitude and phase measurement
5. Phase: 0-359 degrees
6. Gain: 0-90dB, minimum step size 0.5 dB
7. The signal-to-noise ratio of the 0.2mm deep crack defect in the steel/aluminum test block is greater than 10dB
8. Three signals can be displayed simultaneously in one impedance plane
9. Impedance plan and time-based scanning curve display
10. Memory: capable of storing 224 sets of parameters and 99 data
Other performance:
1. Microprocessor: 32-bit
2. Working temperature range: -20 ℃ to+55 ℃
3. Memory: 1G
4. Memory: 64MB
5. USB and network connection transmission
6. External power supply: AC 220V
7. High brightness electroluminescent display screen: 320 * 240 pixels
Shanghai Jiuheng Instrument Co., Ltd. is an enterprise specializing in the research and development, production, sales, and service of instruments and meters. Ultrasonic flaw detectors: (EPOCH 600 ultrasonic flaw detector, EPOCH 6LT ultrasonic flaw detector, EPOCH 650 ultrasonic flaw detector, EPOCH 1000 ultrasonic flaw detector, USM 36 ultrasonic flaw detector, USN 60 ultrasonic flaw detector, USM go+ultrasonic flaw detector, Ominskan SX phased array flaw detector, OmniScan MX2 phased array TOFD flaw detector); Ultrasonic thickness gauge: (27MG ultrasonic thickness gauge, 45MG ultrasonic thickness gauge, 38DL PLUS ultrasonic thickness gauge, DM5E ultrasonic thickness gauge, CL5 ultrasonic thickness gauge, MAGNA-MIKE 8600 Hall effect thickness gauge, ETG-100 electromagnetic high-temperature thickness gauge); Ultrasonic probe; Customized phased array probe; Eddy current flaw detector: (NORTEC 600 eddy current flaw detector); Hardness tester; Endoscopes: (IPLEX NX Olympus Endoscope, IPLEX GX/GT Olympus Endoscope, IPLEX G Lite Olympus Endoscope, IPLEX TX Olympus Endoscope, IPLEX YS Olympus Endoscope, XLGo+Industrial Video Endoscope GE, XL Detect+Industrial Video Endoscope GE New, UVin Professional UV Video Endoscope); Pulse generator: (DRP300 replaces Olympus' 5072PR, 5073PR); Alloy analyzer: (Vanta Olympus handheld alloy analyzer, DELTA Professional handheld alloy analyzer Olympus, DELTA Element handheld alloy analyzer Olympus) and other instruments and meters. Shanghai Jiuheng Instrument Co., Ltd. SWC-2 transverse wave coupling agent, coupling agent for transverse wave probes.