Side mounted magnetic flap level gauges can be used for medium level detection in various equipment such as towers, tanks, tanks, spherical vessels, and boilers. This series of liquid level gauges can achieve high sealing, leak prevention, and are suitable for high temperature, high pressure, and corrosion-resistant applications.
Product Details

Side mounted magnetic flap level gauge


Main technical parameters

1. Measurement range: 0-15000mm
2. Accuracy: ± 10 mm ± 16 mm
3. Flip column diameter: 10mm 16mm
4. Nominal pressure: PN1.6-10.0MPa
5. Nominal diameter: DN20mm
6. Medium density: ≥ 0.45g/cm3
7. Medium density difference: ≥ 0.15g/cm3 (measurement threshold)
8. Medium temperature: -20~+250 ℃ (special requirements can reach 450 ℃)
9. Medium viscosity: ≤ 150CP=200cst. For high viscosity media or media that are prone to crystallization at low temperatures, a steam jacket type liquid level gauge can be selected according to user requirements
10. Environmental vibration: frequency ≤ 25HZ, amplitude ≤ 0.05 mm
11. Follow speed: ≤ 0.08 m/s
12. Connecting flange: Adopting the HG20592-20635-97 standard newly issued by the Ministry of Chemical Industry in 1997. If other standards (such as GB, ANSI, DIN, etc.) are used, please indicate when ordering.
13. The SXG series digital display adjustment alarm and light column display adjustment alarm signal are detailed in the manual.


UHZ-52Z with steam jacket type


UHZ-52Z ordinary type

Technical parameters of transmission device

1. Remote transmission device range: 0-15000mm: If multiple float level gauges of the same model are used simultaneously on the same device due to a large range, the remote transmission part can be used in series with multiple float level gauges of the same model. The remote transmission part can be used in series and must be specified when ordering.
2. Accuracy: ± 10mm
3. Return difference: ± 10mm
4. Output signal: 4-20m A.DC
5. Remote transmission distance: 3km, with cable capacitance and inductance values not exceeding 0.04UF and 2mH
6. Power supply voltage: 24V. DC, 220V. AC50Hz (float level gauge with 24V DC stabilized power supply)
7. Environmental temperature: -40 to+60 ℃
8. Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.05mm
9. Load impedance: 250 Ω
10. Explosion proof hose interface: M20 * 1.5 internal thread
11. Power consumption:<1.0W
12. Explosion proof type and explosion-proof mark: Passed the inspection of the Electrical and Instrumentation Explosion proof Quality Supervision and Inspection Center of the Ministry of Chemical Industry. Explosion proof mark: dllbT4
Explosion proof certificate number: CE991008.


UHZ-52Z anti-corrosion type (304 lined with PP)


UHZ-52Z High Voltage Type

Side mounted magnetic flap level gauge

Technical parameters of alarm system

1. Power supply voltage: 220V, AC, 50Hz
2. Output signal: Two normally open, two normally closed switch signals
3. Switch contact capacity: 220V, 2A
4. Working lifespan:>10 to the power of 5
5. Alarm accuracy: ± 5mm
6. Environmental temperature: -40 to+60 ℃
7. Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm
8. Explosion proof type and explosion-proof mark: Passed the inspection of the Electrical Instrument Explosion proof Quality Supervision and Inspection Center of the Ministry of Chemical Industry. Explosion proof mark dllBT4. Explosion proof certificate number: CE991009
9. Explosion proof hose interface for alarm switch: M20 * 1.5 internal thread.