E-mail
lyboiler@163.com
-
Phone
1580901009
-
Address
Linyi City, Shandong Province
Shandong Tiancheng Boiler Installation Co., Ltd
lyboiler@163.com
1580901009
Linyi City, Shandong Province
Product Code: WY01
Product Name: WNS/SZS Fuel (Gas) Series Boiler
Specification: CWN WNS LNS SZS
Product Features
Fully automatic operation, safe and reliable, the boiler is equipped with various control and protection devices, and the steam pressure, water level, and combustion system are all automatically controlled. The hot water boiler is also equipped with programmed control and temperature control
Degree and time control. Easy to use, labor-saving, and easy to maintain.
Optional imported branded burner, with sufficient fuel combustion and significant energy-saving effect, can be used in areas with high environmental protection requirements.
● Adopt fully enclosed combustion. The boiler room is odorless, noiseless, pollution-free, aesthetically pleasing, and clean.
Compact structure, small footprint, and easy installation.
|
Main performance parameters of CWNS series fully automatic fuel (gas) atmospheric hot water boiler |
|||
|
Boiler model project |
CWN 0.35-95/70-Y(Q) |
CNW 0.7-95/70-Y(Q) |
CNW 1.4-9.5/70-Y(Q) |
|
Rated thermal power MW |
0.35 |
0.7 |
1.4 |
|
Rated working pressure Mpa |
atmospheric pressure |
atmospheric pressure |
atmospheric pressure |
|
Rated return water temperature ℃ |
70 |
70 |
70 |
|
Rated outlet temperature ℃ |
95 |
95 |
95 |
|
Heating surface area m 2 |
17.5 |
37 |
79 |
|
Design fuel |
Oil and gas |
Oil and gas |
Oil and gas |
|
Design efficiency% |
86.63 |
90 |
90 |
|
Fuel consumption (kg/h) |
( 32.53 ) |
( 65 ) |
( 125 ) |
|
burner |
Import |
Import |
Import |
|
This series of boilers can be used with heavy oil, residual oil, coal gas, and natural gas. Please pay attention when ordering. |
|||
|
CWNS series fully automatic atmospheric hot waterNatural gas boilerMain performance parameters |
||||||
|
Boiler model project |
WNS 0.35-0.7/95/70-Y(Q) |
WNS 0.7-0.7/97/70-Y(Q) |
WNS 1.4-0.7/97/70-Y(Q) |
WNS 2.8-0.7/97/70-Y(Q) |
WNS 4.2-0.7/97/70-Y(Q) |
SZS 7-1.0/97/70-Y(Q) |
|
Rated thermal power MW |
0.35 |
0.7 |
1.4 |
2.8 |
4.2 |
7 |
|
Rated working pressure Mpa |
0.7 |
0.7 |
0.7 |
0.7 |
0.7 |
1.0 |
|
Rated outlet temperature ℃ |
95 |
95 |
95 |
95 |
95 |
95 |
|
Rated return water temperature ℃ |
70 |
70 |
70 |
70 |
70 |
70 |
|
Heating surface area m 2 |
17.5 |
29.08 |
59.13 |
111.2 |
166.7 |
377.5 |
|
Design fuel |
Light diesel oil |
Light diesel oil |
Light diesel oil |
Light diesel oil |
Light diesel oil |
Light diesel oil |
|
Design efficiency% |
88.2 |
88.63 |
88.8 |
89.3 |
89.6 |
90.6 |
|
Fuel consumption (kg/h) |
33.9 |
66.3 |
127 |
252 |
377 |
621 |
|
burner |
Import |
Import |
Import |
Import |
Import |
Import |
|
This series of boilers can be used with heavy oil, residual oil, coal gas, and natural gas. Please pay attention when ordering. |
||||||
|
Main performance parameters of WNS/LNS series fully automatic fuel (gas) steam boilers |
||||||||
|
Boiler model project |
WNS 0.5-1.0-Y(Q) |
WNS 1-1.0-Y(Q) |
WNS 2-1.0-Y(Q) |
WNS 2-1.25- Y(Q) |
WNS 4-1.25- Y(Q) |
WNS 6-1.25- Y(Q) |
WNS 0.2-0.7- Y(Q) |
WNS 0.35-0.7- Y(Q) |
|
Rated evaporation capacity t/h |
0.5 |
1 |
2 |
2 |
4 |
6 |
0.2 |
0.35 |
|
Rated working pressure Mpa |
1.0 |
1.0 |
1.0 |
1.25 |
1.25 |
1.25 |
0.7 |
0.7 |
|
Water supply temperature ℃ |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
|
Steam temperature ℃ |
184 |
184 |
184 |
194 |
194 |
194 |
170 |
170 |
|
Heating surface area of boiler m 2 |
14.3 |
28.08 |
59.13 |
58.3 |
105 |
166.7 |
6.22 |
9.15 |
|
Design fuel |
Light diesel oil |
Light diesel oil |
Light diesel oil |
Light diesel oil |
Light diesel oil |
Light diesel oil |
Light diesel oil |
Light diesel oil |
|
Design efficiency% |
82.7 |
84.77 |
86 |
90 |
88 |
88 |
85 |
85 |
|
Fuel consumption (kg/h) |
37.6 |
73.4 |
143 |
143 |
283 |
424 |
14.1 |
23 |
|
burner |
Import |
Import |
Import |
Import |
Import |
Import |
Import |
Import |
|
This series of boilers can be used with heavy oil, residual oil, coal gas, and natural gas. Please pay attention when ordering. |
||||||||
|
Main performance parameters of WNS/LNS series fully automatic fuel (gas) steam boilers |
|||||
|
Boiler model project |
SZS 2-1.25-Y(Q) |
SZS 4-1.25-Y(Q) |
SZS 6-1.25-Y(Q) |
SZS 10-1.25-Y(Q) |
SZS 20-1.25-Y(Q) |
|
Rated evaporation capacity t/h |
2 |
4 |
6 |
10 |
20 |
|
Rated working pressure Mpa |
1.25 |
1.25 |
1.25 |
1.25 |
1.25 |
|
Water supply temperature ℃ |
20 |
20 |
20 |
105 |
105 |
|
Steam temperature ℃ |
194 |
194 |
194 |
194 |
194 |
|
Heating surface area of boiler m 2 |
68.8 |
125.3 |
165.1 |
210 |
435.2 |
|
Heating area of economizer m 2 |
18.48 |
37 |
49.28 |
144 |
236 |
|
Design fuel |
coke oven gas |
coke oven gas |
coke oven gas |
coke oven gas |
coke oven gas |
|
Design efficiency% |
88.99 |
90.35 |
89.67 |
90.24 |
89.17 |
|
Fuel consumption (kg/h) |
347.5 |
684.5 |
1034.57 |
1474.4 |
2984.4 |
|
burner |
Import |
Import |
Import |
Import |
Import |
|
This series of boilers can be used with heavy oil, residual oil, coal gas, and natural gas. Please pay attention when ordering. |
|||||