●Coal water slurry thermal oil boilerIt can achieve high working temperature at lower operating pressure and has the technical characteristics of low pressure and high temperature.
● It can achieve stable heating and precise temperature regulation to meet different requirements.
Under various levels of load, the thermal efficiency can be maintained at the optimal level.
Equipped with complete operation control and safety monitoring devices, easy to operate, safe and reliable. Closed loop circulation, liquid-phase transportation of heat energy, low heat loss, significant energy-saving effect, and low operating cost.
Quick installation or assembly at the factory, convenient transportation, short installation cycle, and quick production results.
The structure is compact and can be arranged separately, saving investment in the boiler room.
The boiler has good insulation performance, using efficient insulation materials and advanced construction technology, resulting in minimal heat loss from the furnace wall.
Main performance parameters of organic heat carrier boilers Boiler model project YGL 120MW QXG 0.24 YGL 350MW QXG 0.45 QXG 0.7 QXL 1.4 LYG ▲ 0.13 LYG ▲ 0.15 Thermal power MW 0.12 (10) 0. 24 (20) 0.35 (30) 0. 45 (40) 0. 7 (60) 0. 45 (120) 0. 13 (10) 0. 15 (12) Thermal efficiency% >65* >65 >69.7* >68 >70 >74 >62 >62 Rated working pressure (Mpa) 1 1 1 1 1 1 0.6 0.3 Coal consumption during full load operation (Kg/h) 21.9 58.0 61.2 82.9 120.2 316.5 31.6 31.6 Heating surface area m 2 14 25.6 48.28 48.3 62.7 101.3 11.72 6.86 Rated working temperature ℃ 300 300 300 300 300 300 300 300 Furnace content oil quantity m 3 0.21 0.3 0.38 0.6 0.8 1.1 0.45 0.6 Circulating oil quantity m 3 8.22 30 23.8 40 60 100 / / Dimensions (length x width x height) mm Φ 1350 x2.055 1800 x1800 x3600 2291 x2079 x2165 2000 x2000 x4200 5800 x2004 x5000 7500 x2800 x6000 1800 x1700 x2500 1800 x1678 x2520 Total installed capacity (KW) 5.1 7.5 10.25 15 15 30 / / Pipe connection diameter Dn (mm) 40 40 80 80 10 125 80 80 Total weight of equipment (Kg) 2882 3412 7072 8200 14800 19500 3072 3072 Note: The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/Kg) The thermal efficiency band * is the design thermal efficiency band ▲ for gas-phase heat transfer oil furnaces Main performance parameters of organic heat carrier boilers Boiler model project YLL1.2 YLL 0.95 YGL 1.2 YGL 0.95 YLL 1.4 YGL 1.4 YGL 0.01 2 YLL 1.8 YLW 1.8 QGL ▲ 350 Thermal power MW (10000 Kcal) 1.2 (100) 0.95 (80) 1.2 (100) 0.95 (80) 1.4 (120) 1.4 (120) 0.012 (1) 1.8 (150) 1.8 (150) 0.35 (30) Thermal efficiency% >74.9 >70.2 >72.7 >70 >74.67 >65 >69.83 >74.4 >74.45 >62.9 Rated working pressure (Mpa) 0.7 0.7 0.7 0.7 1.0 1.0 0.7 0.7 0.7 0.3 Coal consumption during full load operation (Kg/h) 326 275 481.7 228.8 251.8 628.7 2.1 407.7 407.7 74.8 Heating surface area m 2 74.3/34 74.3 74.3/34 74.3 86.2/27.5 86.4 3.06 107.3/32 83.6/32 12.57 Rated working temperature ℃ 300 300 300 300 300 300 280 300 300 300 Furnace content oil quantity m 3 0.86 0.86 0.86 0.86 0.95 0.95 0.011 1.4 1.4 1.0 Circulating oil quantity m 3 69.9 55.33 69.89 55.3 81.5 81.5 2.12 84.1 104.8 / Dimensions (length x width x height) mm 4750 x2162 x1780 4750 x2162 x1780 2440 x2360 x3590 2440 x2360 x3590 5050 x2165 1780 2530 x2410 x3550 Φ 1000 x1400 5850 x2162 x1780 5850 x2162 x1780 1800 x1800 x3109 Total installed capacity (KW) 40.5 25.5 41.25 26.25 45.75 43.95 1.5 41.75 56.75 1.0 Pipe connection diameter Dn (mm) 125 125 125 125 125 125 25 125 150 100 Total weight of equipment (Kg) 16600 16432 9710 9710 18990 11033 1300 22022 29529 4900 Note: The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/Kg) Gas phase thermal oil furnace with ▲ Main performance parameters of organic heat carrier boilers Boiler model project YLW 7.0 (600) YLW6 (500) YLW 5.0 (420) YLW 3.5 (300) YLW 4.2 (360) YGL 0.24 (20) YGL 0.12 (10) YGL 0.75 (60) YGL 0.95 (80) YLW 2.3 (200) Thermal power MW (10000 Kcal) 7.0 (600) 6.0 (500) 5.0 (420) 3.5 (300) 4.2 (360) 0.24 (20) 0.12 (10) 0.75 (60) 0.95 (80) 2.3 (200) Thermal efficiency% >76 >76 >74 >74 >75 >65 >65 >70 >67.7 >74.95 Rated working pressure (Mpa) 0.7 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.7 0.7 Coal consumption during full load operation (Kg/h) 1546 1323 1128 791 943 53 26.4 145 409.8 517.3 Heating surface area m 2 479 413.5 291 180 255 23 14 63 74.3 83.6/32 Rated working temperature ℃ 300 300 320 320 320 300 300 300 300 300 Furnace content oil quantity m 3 4.1 3.5 3.01 2.92 2.71 0.25 0.12 0.92 0.81 1.6 Circulating oil quantity m 3 394 280 70 200 58 16.7 10 51.9 55.33 134 Dimensions (length x width x height) mm 8720 x3400 x5400 7840 x3400 x6340 7300 x3200 x5750 6900 x2720 x5280 6600 x3200 x5750 1945 x1600 x2690 Φ 1350 x2055 1886 x2625 x2405 2440 x2360 x3590 5850 x2162 x1780 Total installed capacity (KW) 163.5 135 138 92.5 119.5 6.6 5.1 23.6 33.25 61.75 Pipe connection diameter Dn (mm) 273 273 219 159 219 57 45 108 125 150 Total weight of equipment (Kg) 63360 60023 43410 32680 46180 3630 2654 7010 9710 23559 Note: The full load coal consumption of the boiler is calculated based on Class II bituminous coal (dw=21320KJ/Kg) The thermal efficiency band * is the design thermal efficiency